差分笛卡尔排序亚采样MRA对治疗后动脉瘤残留分级的诊断价值
本研究纳入68个血管内治疗后的颅内动脉瘤,以DSA为参考标准,比较差分笛卡尔排序亚采样MRA(DISCO-MRA)与TOF-MRA对残留动脉瘤的Modified Raymond-Roy分级诊断效能。DISCO-MRA与DSA的组间一致性κ=0.82,TOF-MRA与DSA为κ=0.44;DISCO-MRA分级与DSA匹配60/68例(88%),TOF-MRA匹配46/68例(68%);DISCO-MRA检出动脉瘤残留的诊断准确度0.96高于TOF-MRA的0.79。
要点
- DISCO-MRA与DSA的Modified Raymond-Roy分级一致性κ=0.82,高于TOF-MRA的κ=0.44。
- DISCO-MRA分级与DSA匹配88%(60/68),TOF-MRA匹配68%(46/68)。
- DISCO-MRA检出残留动脉瘤的诊断准确度0.96,高于TOF-MRA的0.79。
核心结论
- 在血管内治疗后的颅内动脉瘤患者中,DISCO-MRA在显示残留动脉瘤方面的诊断效能优于TOF-MRA,且采集时间仅为TOF-MRA的一小部分。
研究设计与样本
- 纳入同时接受DISCO-MRA、TOF-MRA和DSA检查的血管内治疗颅内动脉瘤患者,共68个治疗后的颅内动脉瘤;DISCO-MRA体素大小0.75×0.75×1 mm³、采集时间6秒,TOF-MRA体素大小0.6×0.6×1 mm³、采集时间6分钟;以DSA为参考标准,由2名神经放射学家独立采用Modified Raymond-Roy分级评估残留动脉瘤。
诊断标准与关键数值
- 以DSA为参考标准,DISCO-MRA与DSA的组间一致性κ=0.82(95%CI 0.67-0.97),TOF-MRA与DSA为κ=0.44(95%CI 0.28-0.61);Modified Raymond-Roy分级评分与DSA匹配:DISCO-MRA 60/68例(88%;χ²=144.4,P<.001),TOF-MRA 46/68例(68%;χ²=65.0,P<.001);检出动脉瘤残留的诊断准确度:DISCO-MRA 0.96(95%CI 0.88-0.99),TOF-MRA 0.79(95%CI 0.68-0.88)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Differential Subsampling with Cartesian Ordering (DISCO), an ultrafast high-spatial-resolution head MRA, has been introduced. We aimed to determine the diagnostic performance of DISCO-MRA in grading residual aneurysm in comparison with TOF-MRA in patients with treated intracranial aneurysms.
MATERIALS AND METHODS: Patients with endovascular treatment and having undergone DISCO-MRA, TOF-MRA, and DSA were included for review. The voxel size and acquisition time were 0.75 × 0.75 × 1 mm3/6 seconds for DISCO-MRA and 0.6 × 0.6 × 1 mm3/6 minutes for TOF-MRA. Residual aneurysms were determined using the Modified Raymond-Roy Classification on TOF-MRA and DISCO-MRA by 2 neuroradiologists independently and were compared against DSA as the reference standard. Statistical analysis was performed using the κ statistic and the χ2 test.
RESULTS: Sixty-eight treated intracranial aneurysms were included. The intermodality agreement was κ = 0.82 (95% CI, 0.67-0.97) between DISCO and DSA and 0.44 (95% CI, 0.28-0.61) between TOF and DSA. Modified Raymond-Roy Classification scores matched DSA scores in 60/68 cases (88%; χ2 = 144.4, P < .001 for DISCO and 46/68 cases (68%; χ2 = 65.0, P < .001) for TOF. The diagnostic accuracy for the detection of aneurysm remnants was higher for DISCO (0.96; 95% CI, 0.88-0.99) than for TOF (0.79; 95% CI, 0.68-0.88).
CONCLUSIONS: In patients with endovascularly treated intracranial aneurysms, DISCO-MRA provides superior diagnostic performance in comparison with TOF-MRA in delineating residual aneurysms in a fraction of the time.
引用
- Shahrouki P, Gupta R, Belani P, et al. Differential Subsampling with Cartesian Ordering-MRA for Classifying Residual Treated Aneurysms. AJNR Am J Neuroradiol. 2022. PMID: 35672082. doi:10.3174/ajnr.A7532
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。