经阴道超声采用国际深部子宫内膜异位症分析(IDEA)方法诊断子宫内膜异位症的前瞻性国际预试验诊断准确性研究
这项国际多中心前瞻性诊断准确性研究纳入273例疑似子宫内膜异位症患者,术前按IDEA共识方法行经阴道超声(TVS),以腹腔镜直视和/或组织学为参考标准。TVS诊断深部子宫内膜异位症(DE)的敏感度88.4%、特异度78.8%(腹腔镜直视)或敏感度89.8%、特异度75.9%(组织学),准确度约86%。
要点
- TVS按IDEA共识方法检测DE总体准确度86.1%(腹腔镜直视)或85.9%(组织学)。
- 以腹腔镜为参考,TVS诊断DE敏感度88.4%、特异度78.8%,LR+ 4.17、LR− 0.15。
- 以组织学为参考,TVS诊断DE敏感度89.8%、特异度75.9%,LR+ 3.72、LR− 0.13。
核心结论
- 采用IDEA共识方法行TVS评估DE具有较高诊断准确性,本研究报告的TVS对DE的总体检出率高于近期一项Meta分析(敏感度79%),但特异度较低。
研究设计与样本
- 国际多中心前瞻性诊断准确性研究,纳入6个国家8个中心,2018年8月至2019年11月连续纳入临床疑似或既往诊断子宫内膜异位症的参与者273例;术前由单名超声医师按IDEA共识行TVS;参考标准为腹腔镜直视(非盲、子宫内膜异位症手术专家判定)和活检/切除组织组织学评估;TVS后12个月内手术。
诊断标准与关键数值
- TVS诊断DE(腹腔镜直视为参考)准确度86.1%、敏感度88.4%、特异度78.8%、PPV 92.9%、NPV 68.4%、LR+ 4.17、LR− 0.15;以组织学为参考准确度85.9%、敏感度89.8%、特异度75.9%、PPV 90.4%、NPV 74.6%、LR+ 3.72、LR− 0.13;组织学确诊子宫内膜异位症256/273(93.8%),其中DE 190/273(69.6%);腹腔镜直视诊断DE 207/273(75.8%)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate the diagnostic accuracy of transvaginal ultrasound (TVS) in predicting deep endometriosis (DE) following the International Deep Endometriosis Analysis (IDEA) consensus methodology.
METHODS: This was an international multicenter prospective diagnostic accuracy study involving eight centers across six countries (August 2018-November 2019). Consecutive participants with endometriosis suspected based on clinical symptoms or historical diagnosis of endometriosis were included. The index test was TVS performed preoperatively in accordance with the IDEA consensus statement. At each center, the index test was interpreted by a single sonologist. Reference standards were: (1) direct visualization of endometriosis at laparoscopy, as determined by a non-blinded surgeon with expertise in endometriosis surgery; and (2) histological assessment of biopsied/excised tissue. Surgery was performed within 12 months following the index TVS. Accuracy, sensitivity, specificity, positive and negative predictive values (PPV and NPV) and positive and negative likelihood ratios (LR+ and LR-) of TVS in the diagnosis of DE were calculated.
RESULTS: Included in the study were 273 participants with complete clinical, TVS, laparoscopic and histological data. Of these, based on histology, 256 (93.8%) were confirmed to have endometriosis, including superficial endometriosis, and 190 (69.6%) were confirmed to have DE. Based on surgical visualization, 207/273 (75.8%) patients had DE. For DE overall, the diagnostic performance of TVS based on surgical visualization as the reference standard was as follows: accuracy, 86.1%; sensitivity, 88.4%; specificity, 78.8%; PPV, 92.9%; NPV, 68.4%; LR+, 4.17; LR-, 0.15, and the diagnostic performance of TVS based on histology as the reference standard was as follows: accuracy, 85.9%; sensitivity, 89.8%; specificity, 75.9%; PPV, 90.4%; NPV, 74.6%; LR+, 3.72; LR-, 0.13.
CONCLUSIONS: Using the IDEA consensus methodology provides strong diagnostic accuracy for TVS assessment of DE. We found a higher TVS detection rate of DE overall than that reported by the most recent meta-analysis on the topic (sensitivity, 79%), albeit with a lower specificity. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Leonardi M, Uzuner C, Mestdagh W, et al. Diagnostic accuracy of transvaginal ultrasound for detection of endometriosis using International Deep Endometriosis Analysis (IDEA) approach: prospective international pilot study. Ultrasound Obstet Gynecol. 2022. PMID: 35561121. doi:10.1002/uog.24936
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。