磁共振成像与盆底超声诊断提肛肌撕裂的诊断试验准确性
该横断面研究纳入135名初产后4年女性,评估MRI、经会阴超声和经阴道超声对提肛肌撕裂的诊断准确性。以潜在类别分析估计的患病率为15.7%,MRI敏感度100%、特异度91%,经阴道超声敏感度91%、特异度95%,经会阴超声敏感度71%、特异度100%。作者认为超声因高特异度可作为分诊试验,但因敏感度较低不能替代MRI。
要点
- MRI对提肛肌撕裂敏感度最高(100%),经会阴超声特异度最高(100%)。
- 经阴道超声与MRI诊断一致性最高(κ=0.69),裂孔测量ICC为0.60-0.81。
- 超声预测提肛肌撕裂存在的效能中等,预测其不存在的效能很好。
核心结论
- 盆底超声因高特异度可作为筛查提肛肌撕裂的分诊试验,但因敏感度较低不能替代MRI;超声预测撕裂存在的效能中等、预测不存在的效能很好;阳性结果应由不同观察者或影像技术确认。
研究设计与样本
- 横断面研究,纳入135名初产后4年女性,全部接受四维经会阴超声、三维经阴道超声和MRI检查,图像由两名盲法观察者分析,采用预设截断值诊断提肛肌撕裂,无参考标准时采用潜在类别分析建立诊断试验特征。
诊断标准与关键数值
- 提肛肌撕裂患病率:MRI 23.0%,经会阴超声11.1%,经阴道超声17.8%,潜在类别分析估计为15.7%。敏感度:经会阴超声71%(95%CI 50-90%),经阴道超声91%(95%CI 74-100%),MRI 100%(95%CI 84-100%)。特异度:经会阴超声100%(95%CI 97-100%),经阴道超声95%(95%CI 91-99%),MRI 91%(95%CI 85-97%)。主要提肛肌撕裂的预测值:MRI阳性预测值95%、阴性预测值100%;经阴道超声阳性预测值100%、阴性预测值98%。次要提肛肌撕裂:经会阴超声阳性预测值100%、阴性预测值95%。
临床应用与阅片要点
- 经会阴超声和经阴道超声可用于初产女性的提肛肌撕裂分诊评估,但超声不能替代MRI;MRI和经阴道超声诊断的主要提肛肌撕裂与阴道前壁脱垂相关,经会阴超声未发现此关联;阳性结果应由不同观察者或影像技术确认。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To estimate the diagnostic test accuracy of magnetic resonance imaging (MRI) and pelvic floor ultrasound for levator ani muscle (LAM) avulsion in a general parous population, with view to establishing if ultrasound could substitute for MRI to diagnose LAM avulsion.
METHODS: This was a cross-sectional study of 135 women 4 years after their first delivery. Signs and symptoms of pelvic floor dysfunction were assessed using validated methods. All women underwent four-dimensional transperineal ultrasound (TPUS), three-dimensional endovaginal ultrasound (EVUS) and MRI. Images were acquired at rest, on pelvic floor muscle contraction (PFMC) and on maximum Valsalva maneuver, and analyzed by two blinded observers. Predefined cut-off values were used to diagnose LAM avulsion. In the absence of a reference standard, latent class analysis (LCA) was used to establish diagnostic test characteristics for LAM avulsion as the primary outcome measure. Secondary outcomes were kappa (κ) agreement between imaging techniques, intraclass correlation coefficients (ICC) for hiatal measurements at rest, on PFMC and on maximum Valsalva maneuver, and the association of LAM avulsion with signs and symptoms of pelvic floor dysfunction.
RESULTS: The prevalence of LAM avulsion was 23.0% for MRI, 11.1% for TPUS and 17.8% for EVUS. The prevalence of LAM avulsion using LCA was 15.7%. The sensitivity for LAM avulsion of TPUS (71% (95% CI, 50-90%)) and EVUS (91% (95% CI, 74-100%)) was lower than that of MRI (100% (95% CI, 84-100%)). The specificity of TPUS (100% (95% CI, 97-100%)) and EVUS (95% (95% CI, 91-99%)) was higher than that of MRI (91% (95% CI, 85-97%)). MRI and EVUS had high predictive values for the assessment of major LAM avulsion (positive predictive value (PPV), 95% and negative predictive value (NPV), 100%; PPV, 100% and NPV, 98%, respectively), while TPUS had high predictive values for minor LAM avulsion (PPV, 100% and NPV, 95%). Major LAM avulsion on MRI and EVUS was associated with anterior vaginal wall prolapse, which was not found for TPUS. The agreement in the diagnosis of LAM avulsion (κ, 0.69) and hiatal measurements (ICC, 0.60-0.81) was highest between MRI and EVUS.
CONCLUSIONS: Pelvic floor ultrasound can be implemented as a triage test to assess parous women for LAM avulsion because of its high specificity. Ultrasound cannot substitute for MRI because of its lower sensitivity. The predictive ability of ultrasound is moderate for the presence, and very good for the absence, of LAM avulsion. A positive test should be confirmed by a different observer or imaging technique. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Van Gruting IMA, Stankiewicz A, Van Delft KWM, et al. Diagnostic test accuracy of magnetic resonance imaging and pelvic floor ultrasound for diagnosis of levator ani muscle avulsion. Ultrasound Obstet Gynecol. 2022. PMID: 35633511. doi:10.1002/uog.24955
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。