自由呼吸动态T1WI采用压缩感知黄金角径向稀疏并行成像用于屏气能力受限患者的肝脏MRI
回顾性研究纳入2018年3月至2019年10月接受钆塞酸增强肝脏MRI并使用CS-GRASP的102例患者,按时间分为两组:组1(n=41)为序列实施期不论屏气能力者,组2(n=61)为因屏气能力受限自2018年6月起检查者。结果显示组1在晚动脉期图像质量评分和条纹伪影评分均高于组2,但两组可接受运动伪影比例和可接受图像质量比例无显著差异;作者结论为非合作患者晚动脉期通过自由呼吸CS-GRASP T1WI可获得可接受图像质量,成功率超过50%。
要点
- 晚动脉期组1图像质量评分3.22±0.65 vs 组2 2.95±0.61,组1更高(P<0.001)。
- 晚动脉期组1条纹伪影评分2.96±0.56 vs 组2 2.74±0.57,组1伪影更少(P=0.001)。
- 两组可接受运动伪影比例和可接受图像质量比例无显著差异(P>0.05)。
核心结论
- 非合作患者采用自由呼吸CS-GRASP T1WI在晚动脉期可获得可接受图像质量,成功率超过50%。
研究设计与样本
- 回顾性研究纳入2018年3月至2019年10月接受钆塞酸增强肝脏MRI并使用CS-GRASP的102例患者,按时间分为组1(n=41)和组2(n=61),由三名放射科医生在平扫期、晚动脉期和门静脉期对运动伪影、条纹伪影及整体图像质量进行四点法评分。
关键影像表现/征象
- 晚动脉期组1图像质量评分3.22±0.65 vs 组2 2.95±0.61,组1更高(P<0.001)。
- 晚动脉期组1条纹伪影评分2.96±0.56 vs 组2 2.74±0.57,组1伪影更少(P=0.001)。
- 两组可接受运动伪影比例:组1 92.7%(38/41) vs 组2 96.7%(59/61),无显著差异(P>0.05)。
- 两组可接受图像质量比例:组1 80.5%(33/41) vs 组2 65.6%(40/61),无显著差异(P>0.05)。
- 组内比较中,两组均为门静脉期图像质量最高(P<0.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Evaluating the performance of free-breathing dynamic T1-weighted imaging (T1WI) using compressed sensing golden-angle radial sparse parallel imaging (CS-GRASP) in non-cooperative patients compared with a general group.
METHOD: This retrospective study included patients who underwent gadoxetic acid-enhanced liver MRI using CS-GRASP at 3 T between March 2018 and October 2019. Patients were divided chronologically, into one of two groups: Group 1, who underwent MRI during the sequence implementation period regardless of breath-hold capability; and Group 2, who underwent MRI from June 2018 due to limited breath-hold capability. Three radiologists evaluated motion and streak artifacts as well as overall image quality on a four-point scale at the precontrast phase, late arterial phase (LAP) and portal venous phase (PVP). Intra-individual comparisons were made between sequences in each group.
RESULTS: We identified 102 patients, who were divided into either Group 1 (n = 41) or 2 (n = 61). For the LAP, the former group had higher image quality (3.22 ± 0.65 vs. 2.95 ± 0.61, P < 0.001) and less streak artifact (2.96 ± 0.56 vs. 2.74 ± 0.57, P = 0.001) than the latter. However, there was no significant difference between the two groups regarding either the proportion of patients with acceptable motion artifact, at 92.7% (38/41) for Group 1 vs. 96.7% (59/61) for Group 2, or that of patients with acceptable image quality at 80.5% (33/41) for Group 1 vs. 65.6% (40/61) for Group 2 (P > 0.05). In intra-individual comparisons, portal phase showed the highest image quality than the others in both groups (P < 0.001).
CONCLUSIONS: Acceptable image quality for the LAP in non-cooperative patients was provided with a success rate of over 50% via free-breathing T1WI using CS-GRASP.
引用
- Young Park J, Min Lee S, Sub Lee J, et al. Free-breathing dynamic T1WI using compressed sensing-golden angle radial sparse parallel imaging for liver MRI in patients with limited breath-holding capability. Eur J Radiol. 2022. PMID: 35597070. doi:10.1016/j.ejrad.2022.110342
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。