文献速递神经外周血管MR

使用DANTE或DANTE-CAIPI进行血液抑制和成像加速的3D颅内血管壁MRI图像质量评估

Image-Quality Assessment of 3D Intracranial Vessel Wall MRI Using DANTE or DANTE-CAIPI for Blood Suppression and Imaging Acceleration.
PubMed 文献 · AJNR Am J Neuroradiol · 2022-05-26

连续89例患者接受常规增强3D T1-SPACE及DANTE或DANTE-CAIPI血流抑制加速序列,评估图像质量、信噪比、伪影、血液抑制及病变评估。T1-DANTE-CAIPI-SPACE伪影少、运动少、血液抑制好、扫描时间短,但信噪比及管腔对比度低于常规序列;T1-DANTE-SPACE信噪比及血液抑制优于常规序列,但扫描时间略长。

要点

  • T1-DANTE-SPACE在图像质量、信噪比、伪影、动静脉抑制及病变评估上显著优于T1-SPACE(各P<0.001)。
  • T1-DANTE-CAIPI-SPACE图像质量、病变评估及血液抑制优于T1-SPACE,伪影及运动更少(各P<0.001)。
  • T1-DANTE-CAIPI-SPACE扫描时间5分11秒,短于T1-SPACE的8分08秒和T1-DANTE-SPACE的8分41秒。

核心结论

  • 加速增强T1-DANTE-CAIPI-SPACE图像伪影更少、运动更少、血液抑制更好且扫描时间更短,但定性和定量信噪比低于常规T1-SPACE颅内血管壁MRI;增强T1-DANTE-SPACE信噪比、血液抑制、图像质量及伪影方面优于T1-SPACE,但扫描时间略长。

研究设计与样本

  • 连续患者接受颅内血管壁MRI,包括常规增强3D T1-SPACE及增强DANTE血流抑制或DANTE-CAIPI血流抑制加速T1-SPACE序列,共纳入89例患者;采用4分或5分Likert量表评估图像质量、信噪比、伪影程度及范围、运动、血液抑制、锐利度及病变评估,并定量评估管腔及管壁与管腔对比比。

诊断标准与关键数值

  • T1-DANTE-SPACE对比T1-SPACE:图像质量、信噪比、伪影影响、动脉及静脉抑制、病变评估均显著更好(各P<0.001),运动无显著差异(P=0.16)。
  • T1-DANTE-CAIPI-SPACE对比T1-SPACE:图像质量、病变评估、动脉及静脉血液抑制显著更好,伪影影响及运动显著更少(各P<0.001)。
  • T1-SPACE信噪比高于T1-DANTE-CAIPI-SPACE(P<0.001)。
  • T1-DANTE-CAIPI-SPACE管腔对比比(P=0.005)及管壁与管腔对比比(P=0.001)显著低于T1-SPACE;T1-SPACE与T1-DANTE-SPACE之间无显著差异。
  • 扫描时间:T1-DANTE-CAIPI-SPACE为5分11秒,常规T1-SPACE为8分08秒,T1-DANTE-SPACE为8分41秒。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: 3D intracranial vessel wall MRI techniques are time consuming and prone to artifacts, especially flow artifacts. Our aim was to compare the image quality of accelerated and flow-suppressed 3D intracranial vessel wall MR imaging techniques relative to conventional acquisitions.

MATERIALS AND METHODS: Consecutive patients undergoing MR imaging had conventional postcontrast 3D T1-sampling perfection with application-optimized contrasts by using different flip angle evolution (SPACE) and either postcontrast delay alternating with nutation for tailored excitation (DANTE) flow-suppressed or DANTE-controlled aliasing in parallel imaging results in higher acceleration (CAIPI) flow-suppressed and accelerated T1-SPACE sequences performed. The sequences were evaluated using 4- or 5-point Likert scales for overall image quality, SNR, extent/severity of artifacts, motion, blood suppression, sharpness, and lesion assessment. Quantitative assessment of lumen and wall-to-lumen contrast ratios was performed.

RESULTS: Eighty-nine patients were included. T1-DANTE-SPACE had significantly better qualitative ratings relative to T1-SPACE for image quality, SNR, artifact impact, arterial and venous suppression, and lesion assessment (P < .001 for each, respectively), with the exception of motion (P = .16). T1-DANTE-CAIPI-SPACE had significantly better image quality, lesion assessment, arterial and venous blood suppression, less artifact impact, and less motion compared with T1-SPACE (P < .001 for each, respectively). The SNR was higher with T1-SPACE compared with T1-DANTE-CAIPI-SPACE (P < .001). T1-DANTE-CAIPI-SPACE showed significantly worse lumen (P = .005) and wall-to-lumen contrast ratios (P = .001) compared with T1-SPACE, without a significant difference between T1-SPACE and T1-DANTE-SPACE. T1-DANTE-CAIPI-SPACE scan time was 5:11 minutes compared with 8:08 and 8:41 minutes for conventional T1-SPACE and T1-DANTE-SPACE, respectively.

CONCLUSIONS: Accelerated postcontrast T1-DANTE-CAIPI-SPACE had fewer image artifacts, less motion, improved blood suppression, and a shorter scan time, but lower qualitative and quantitative SNR ratings relative to conventional T1-SPACE intracranial vessel wall MR imaging. Postcontrast T1-DANTE-SPACE had superior SNR, blood suppression, higher image quality, and fewer image artifacts, but slightly longer scan times relative to T1-SPACE.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Sannananja B, Zhu C, Colip CG, et al. Image-Quality Assessment of 3D Intracranial Vessel Wall MRI Using DANTE or DANTE-CAIPI for Blood Suppression and Imaging Acceleration. AJNR Am J Neuroradiol. 2022. PMID: 35618420. doi:10.3174/ajnr.A7531

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。