文献速递神经MR

7T MRI上深部灰质微梗死:危险因素、MRI相关表现及其与认知功能的关系——SMART-MR研究

Microinfarcts in the Deep Gray Matter on 7T MRI: Risk Factors, MRI Correlates, and Relation to Cognitive Functioning-The SMART-MR Study.
PubMed 文献 · AJNR Am J Neuroradiol · 2022-05-26

在SMART-MR研究的213例患者中,7T MRI发现28例(13%)共47个深部灰质微梗死,最常见于丘脑。高龄、卒中史、高血压和内膜-中膜厚度与微梗死相关;1.5T MRI上的小脑梗死、白质和深部灰质腔隙灶以及7T MRI上的皮层微梗死也与微梗死相关。多发微梗死患者整体认知功能z评分较无微梗死患者低0.97(95%CI -1.66至-0.28,P=0.006),且涉及所有认知域。

要点

  • 7T MRI上深部灰质微梗死定义为<5 mm的病灶,最常见于丘脑。
  • 1.5T MRI上的小脑梗死、白质腔隙灶和深部灰质腔隙灶与深部灰质微梗死相关。
  • 多发深部灰质微梗死与整体及所有认知域认知功能较差相关。

核心结论

  • 7T MRI上的深部灰质微梗死与较差的认知功能以及小血管和大血管疾病的危险因素和MRI标志物相关;作者认为深部灰质微梗死可能代表一种新的血管性脑损伤影像标志物。

研究设计与样本

  • SMART-MR研究中的213例患者(平均年龄68岁,SD 8)接受了危险因素评估、7T和1.5T脑MRI以及认知检查;采用回归模型分析年龄校正后危险因素、MRI标志物与微梗死之间的关联。

关键影像表现/征象

  • 7T MRI上深部灰质微梗死定义为<5 mm的病灶,28例(13%)患者共发现47个微梗死,最常见于丘脑。
  • 1.5T MRI上小脑梗死(相对危险度=2.75;95%CI 1.4-5.33)、白质腔隙灶(相对危险度=3.28;95%CI 3.28-6.04)和深部灰质腔隙灶(相对危险度=3.06;95%CI 1.75-5.35)与微梗死相关。
  • 7T MRI上皮层微梗死(相对危险度=2.33;95%CI 1.32-4.13)与深部灰质微梗死相关。

诊断标准与关键数值

  • 7T MRI上深部灰质微梗死定义为病灶<5 mm。
  • 多发微梗死患者与无微梗死患者整体认知功能z评分的平均差值为-0.97(95%CI -1.66至-0.28,P=0.006)。

临床应用与阅片要点

  • 在7T MRI阅片时,应注意深部灰质(尤其是丘脑)<5 mm的微梗死病灶。
  • 1.5T MRI上发现小脑梗死、白质腔隙灶或深部灰质腔隙灶时,提示可能存在深部灰质微梗死。
  • 7T MRI上发现皮层微梗死时,也应关注深部灰质微梗死。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: The clinical relevance of cortical microinfarcts has recently been established; however, studies on microinfarcts in the deep gray matter are lacking. We examined the risk factors and MR imaging correlates of microinfarcts in the deep gray matter on 7T MR imaging and their relation to cognitive functioning.

MATERIALS AND METHODS: Within the Second Manifestations of ARTerial disease-Magnetic Resonance (SMART-MR) study, 213 patients (mean age, 68 [SD, 8] years) had a risk-factor assessment, 7T and 1.5T brain MR imaging, and a cognitive examination. Microinfarcts on 7T MR imaging were defined as lesions of <5 mm. Regression models were used to examine the age-adjusted associations among risk factors, MR imaging markers, and microinfarcts. Cognitive function was summarized as composite and domain-specific z scores.

RESULTS: A total of 47 microinfarcts were found in 28 patients (13%), most commonly in the thalamus. Older age, history of stroke, hypertension, and intima-media thickness were associated with microinfarcts. On 1.5T MR imaging, cerebellar infarcts (relative risk = 2.75; 95% CI, 1.4-5.33) and lacunes in the white (relative risk = 3.28; 95% CI, 3.28-6.04) and deep gray matter (relative risk = 3.06; 95% CI, 1.75-5.35) were associated with microinfarcts, and on 7T MR imaging cortical microinfarcts (relative risk = 2.33; 95% CI, 1.32-4.13). Microinfarcts were also associated with poorer global cognitive functioning (mean difference in the global z score between patients with multiple microinfarcts versus none = -0.97; 95% CI, -1.66 to -0.28, P = .006) and across all cognitive domains.

CONCLUSIONS: Microinfarcts in the deep gray matter on 7T MR imaging were associated with worse cognitive functioning and risk factors and MR imaging markers of small-vessel and large-vessel disease. Our findings suggest that microinfarcts in the deep gray matter may represent a novel imaging marker of vascular brain injury.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Ghaznawi R, Zwartbol MHT, de Bresser J, et al. Microinfarcts in the Deep Gray Matter on 7T MRI: Risk Factors, MRI Correlates, and Relation to Cognitive Functioning-The SMART-MR Study. AJNR Am J Neuroradiol. 2022. PMID: 35618425. doi:10.3174/ajnr.A7512

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。