多发性硬化患者钆增强「黑血」3D T1-SPACE 图像上非病灶性对比增强的来源

Nonlesional Sources of Contrast Enhancement on Postgadolinium "Black-Blood" 3D T1-SPACE Images in Patients with Multiple Sclerosis.
PubMed 文献 · AJNR Am J Neuroradiol · 2022-05-26

研究纳入232例多发性硬化、临床孤立综合征或放射学孤立综合征患者,比较SPACE与标准MPRAGE及容积插值脑检查图像的对比增强病灶检出。SPACE上脑实质内静脉对比噪声比更高,真阳性和假阳性均更多,假阳性似然比增加(OR=3.03-3.55),静脉来源假阳性(n=59)形态与≤14 mm³真阳性相似。

要点

  • 黑血SPACE图像上脑实质内静脉可表现为类似小病灶的强化,是假阳性来源。
  • SPACE的静脉对比噪声比高于MPRAGE和容积插值脑检查图像(P<.001)。
  • SPACE假阳性似然比增加(OR=3.03-3.55),但真阳性似然比未增加。

核心结论

  • 脑实质内小静脉可能干扰钆增强黑血SPACE图像上强化病灶的诊断。

研究设计与样本

  • 比较SPACE与标准MPRAGE及容积插值脑检查图像,纳入232例多发性硬化、临床孤立综合征或放射学孤立综合征患者,由2名专家和1名初学者盲法检出强化病灶,以资深阅片者共识判定真阳性和假阳性。

关键影像表现/征象

  • SPACE图像上脑实质内静脉对比噪声比高于MPRAGE和容积插值脑检查图像(P<.001,两者)。
  • 静脉来源假阳性(n=59)的对比噪声比和形态特征与小尺寸(≤14 mm³)真阳性相似(P=.544)。
  • SPACE图像上静脉来源假阳性出现更频繁(P<.001)。

诊断标准与关键数值

  • 真阳性与假阳性由资深阅片者共识确定。
  • SPACE检出更多真阳性和假阳性(P范围<.001-.07),但未增加患者真阳性似然比(OR=1-1.29,P=.478-1)。
  • SPACE增加假阳性似然比(OR=3.03-3.55,P=.008-.027)。

临床应用与阅片要点

  • 判读钆增强黑血SPACE图像时,需注意脑实质内静脉强化可能酷似小强化病灶。
  • 静脉来源假阳性形态与小尺寸(≤14 mm³)真阳性相似,可结合对比噪声比和形态特征鉴别。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: We hypothesized that 3D T1-TSE "black-blood" images may carry an increased risk of contrast-enhancing lesion misdiagnosis in patients with MS because of the misinterpretation of intraparenchymal vein enhancement. Thus, the occurrence of true-positive and false-positive findings was compared between standard MPRAGE and volumetric interpolated brain examination techniques.

MATERIALS AND METHODS: Sampling perfection with application-optimized contrasts by using different flip-angle evolution (SPACE) images obtained from 232 patients with MS, clinically isolated syndrome, or radiologically isolated syndrome were compared with standard MPRAGE and volumetric interpolated brain examination images. The intraparenchymal vein contrast-to-noise ratio was estimated at the level of the thalami. Contrast-enhancing lesions were blindly detected by 2 expert readers and 1 beginner reader. True- and false-positives were determined by senior readers' consensus. True-positive and false-positive frequency differences and patient-level diagnosis probability were tested with the McNemar test and OR. The contrast-to-noise ratio and morphology were compared using the Mann-Whitney U and χ2 tests.

RESULTS: The intraparenchymal vein contrast-to-noise ratio was higher in SPACE than in MPRAGE and volumetric interpolated brain examination images (P < .001, both). There were 66 true-positives and 74 false-positives overall. SPACE detected more true-positive and false-positive results (P range < .001-.07) but did not increase the patient's true-positive likelihood (OR = 1 1.29, P = .478-1). However, the false-positive likelihood was increased (OR = 3.03-3.55, P = .008-.027). Venous-origin false-positives (n = 59) with contrast-to-noise ratio and morphology features similar to small-sized (≤14 mm3 P = .544) true-positives occurred more frequently in SPACE images (P < .001).

CONCLUSIONS: Small intraparenchymal veins may confound the diagnosis of enhancing lesions on postgadolinium black-blood SPACE images.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Danieli L, Roccatagliata L, Distefano D, et al. Nonlesional Sources of Contrast Enhancement on Postgadolinium "Black-Blood" 3D T1-SPACE Images in Patients with Multiple Sclerosis. AJNR Am J Neuroradiol. 2022. PMID: 35618421. doi:10.3174/ajnr.A7529

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。