文献速递腹部CT

常规与基于能谱的标记粪便清除算法在CT结肠成像中的性能比较

Comparison of the performance of conventional and spectral-based tagged stool cleansing algorithms at CT colonography.
PubMed 文献 · Eur Radiol · 2022-04-29

回顾性评估30例连续患者的碘标记CT结肠成像,比较常规与两种能谱电子清除算法。能谱清除总体伪影严重程度更低、可读性更高,但过度清除伪影更重;结论认为能谱清除更稳健,仍需进一步临床试验。

要点

  • 能谱清除总体伪影评分≥2的比例低于常规清除(透明60%、半透明50% vs 常规66%)。
  • 能谱清除过度清除伪影评分≥2的比例高于常规清除(透明17%、半透明14% vs 常规9%)。
  • 能谱清除总体可读性较常规清除显著改善(两种算法均p<0.001)。

核心结论

  • 能谱电子清除对CT结肠成像中碘标记粪便的清除比常规清除更稳健。

研究设计与样本

  • 回顾性评估30例连续患者(平均年龄69±8岁)的碘对比剂粪便标记CT结肠成像,使用双层能谱探测器CT扫描仪,以常规清除算法和两种实验性能谱清除算法进行比较。

诊断标准与关键数值

  • 伪影严重程度采用5点Likert量表(0=无至4=严重);常规清除总体伪影评分≥2占66%,透明能谱清除占60%(p=0.011),半透明能谱清除占50%(p<0.001);清除不足评分≥2常规60%、透明49%(p<0.001)、半透明39%(p<0.001);过度清除评分≥2常规9%、透明17%(p<0.001)、半透明14%(p=0.023);总体可读性透明和半透明能谱清除均较常规显著改善(均p<0.001)。

临床应用与阅片要点

  • 作者认为能谱电子清除可能推动CT结肠成像采用更轻度导泻方案,但指出仍需进一步临床试验。

局限性

  • 原文结论指出能谱电子清除可能推动更轻度导泻的CT结肠成像方法,仍需进一步临床试验。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To compare the performance of conventional versus spectral-based electronic stool cleansing for iodine-tagged CT colonography (CTC) using a dual-layer spectral detector scanner.

METHODS: We retrospectively evaluated iodine contrast stool-tagged CTC scans of 30 consecutive patients (mean age: 69 ± 8 years) undergoing colorectal cancer screening obtained on a dual-layer spectral detector CT scanner. One reader identified locations of electronic cleansing artifacts (n = 229) on conventional and spectral cleansed images. Three additional independent readers evaluated these locations using a conventional cleansing algorithm (Intellispace Portal) and two experimental spectral cleansing algorithms (i.e., fully transparent and translucent tagged stool). For each cleansed image set, readers recorded the severity of over- and under-cleansing artifacts on a 5-point Likert scale (0 = none to 4 = severe) and readability compared to uncleansed images. Wilcoxon's signed-rank tests were used to assess artifact severity, type, and readability (worse, unchanged, or better).

RESULTS: Compared with conventional cleansing (66% score ≥ 2), the severity of overall cleansing artifacts was lower in transparent (60% score ≥ 2, p = 0.011) and translucent (50% score ≥ 2, p < 0.001) spectral cleansing. Under-cleansing artifact severity was lower in transparent (49% score ≥ 2, p < 0.001) and translucent (39% score ≥ 2, p < 0.001) spectral cleansing compared with conventional cleansing (60% score ≥ 2). Over-cleansing artifact severity was worse in transparent (17% score ≥ 2, p < 0.001) and translucent (14% score ≥ 2, p = 0.023) spectral cleansing compared with conventional cleansing (9% score ≥ 2). Overall readability was significantly improved in transparent (p < 0.001) and translucent (p < 0.001) spectral cleansing compared with conventional cleansing.

CONCLUSIONS: Spectral cleansing provided more robust electronic stool cleansing of iodine-tagged stool at CTC than conventional cleansing.

KEY POINTS: • Spectral-based electronic cleansing of tagged stool at CT colonography provides higher quality images with less perception of artifacts than does conventional cleansing. • Spectral-based electronic cleansing could potentially advance minimally cathartic approach for CT colonography. Further clinical trials are warranted.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Grosu S, Wiemker R, An C, et al. Comparison of the performance of conventional and spectral-based tagged stool cleansing algorithms at CT colonography. Eur Radiol. 2022. PMID: 35486170. doi:10.1007/s00330-022-08831-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。