检测肥厚型心肌病局灶性纤维化:基于心脏磁共振的心肌应变效用
该回顾性研究纳入127例肥厚型心肌病患者和30例健康对照,分析心脏磁共振心肌应变参数与延迟钆增强所示纤维化的关系。结果显示,节段周向应变(SCS)与最大室壁厚度(MWT)均可鉴别有无延迟钆增强的节段,SCS的AUC为0.803;联合SCS >-13.9%与MWT >16.4mm时模型特异度最高达93.9%,敏感度61.8%。
要点
- 节段周向应变(SCS)是识别肥厚型心肌病纤维化节段的最佳应变参数,AUC 0.803。
- 联合SCS >-13.9%与MWT >16.4mm可获最高特异度93.9%,敏感度61.8%。
- 最大室壁厚度(MWT)单独识别纤维化的AUC为0.777。
核心结论
- 在肥厚型心肌病患者中,基于心脏磁共振的应变分析有希望用于检测心肌纤维化,其中节段周向应变是最佳应变参数;联合节段周向应变与最大室壁厚度的模型可获得最高的纤维化诊断特异度。
研究设计与样本
- 回顾性纳入127例肥厚型心肌病患者(男89例,平均年龄46.6±15.6岁)和30例健康对照(男20例,平均年龄52.0±13.2岁),均行延迟钆增强心脏磁共振检查;127例患者随机分为训练集和验证集;测量并统计分析应变与影像参数,以延迟钆增强作为纤维化参考标准。
诊断标准与关键数值
- 节段周向应变识别心肌纤维化的AUC为0.803(95%CI 0.785-0.820),最大室壁厚度为0.777(95%CI 0.759-0.795);联合节段周向应变 >-13.9%与最大室壁厚度 >16.4mm时,模型AUC为0.779(95%CI 0.760-0.796),特异度最高达93.9%,敏感度61.8%。
临床应用与阅片要点
- 作者结论认为应变分析在肥厚型心肌病中有希望用于检测心肌纤维化,且节段周向应变为最佳应变参数;联合节段周向应变与最大室壁厚度的模型可获得最高的纤维化诊断特异度。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: The value of myocardial strain for reflecting fibrosis in patients with hypertrophic cardiomyopathy (HCM) on cardiac magnetic resonance (CMR) has not been definite. We aim to explore whether there are underlying non-contrast parameters to evaluate myocardial fibrosis and screen which may be the best.
MATERIALS AND METHODS: We retrospectively included 127 HCM patients (89 men; average age 46.6 ± 15.6 years) and 30 healthy controls (20 men; average age 52.0 ± 13.2 years) who have undergone late gadolinium enhancement (LGE) CMR. Next, 127 HCM patients were divided randomly into two sets including training cohort and validation cohort. Strain and imaging parameters were measured and analyzed statistically.
RESULTS: Based on univariate and multivariate analysis, segmental circumferential strain (SCS) (p < 0.001) and maximal wall thickness (MWT) (p < 0.001) may differentiate myocardial segments with or without LGE as significant biomarkers for both sets. The area under the curve (AUC) was 0.803 (95% CI 0.785-0.820) for SCS and 0.777 (95% CI 0.759-0.795) for MWT to identify myocardial fibrosis. When combining SCS >-13.9% and MWT >16.4mm, the specificity of the model (AUC = 0.779; 95% CI 0.760-0.796) achieved the highest 93.9%, with a sensitivity of 61.8%.
CONCLUSION: Strain analysis in HCM holds promise for myocardial fibrosis detection and SCS is the best strain parameter based on CMR. Nevertheless, the model of combining SCS and MWT could achieve the highest specificity for fibrotic diagnosis.
引用
- She J, Zhao S, Chen Y, et al. Detecting Regional Fibrosis in Hypertrophic Cardiomyopathy: The Utility of Myocardial Strain Based on Cardiac Magnetic Resonance. Acad Radiol. 2022. PMID: 35469720. doi:10.1016/j.acra.2022.03.022
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。