文献速递骨肌技术与安全CT

单能量投影基金属伪影减少(SEMAR)在不同髋部骨科硬件中的可靠性与获益

Reliability and benefits of single-energy projection-based metallic artifact reduction (SEMAR) in the different orthopedic hardware for the hip.
PubMed 文献 · Skeletal Radiol · 2022-03-26

回顾性纳入2015年2月至2019年10月153例髋部骨科硬件置入后行CT检查的患者,按硬件类型分5组,比较自适应迭代剂量降低(AIDR)3D与SEMAR算法的伪影程度和图像质量。SEMAR图像中膀胱、静脉和脂肪的平均密度与参考图像无显著差异,但SEMAR图像中膀胱的噪声显著高于AIDR 3D参考图像;所有AIDR 3D图像均不可诊断(总体质量≤3分),而SEMAR图像中仅16.7%-23.7%不可诊断,主要见于假体患者。结论认为SEMAR算法显著减少CT金属伪影,对内置固定物患者的效果优于假体患者,并提供可靠的软组织衰减。

要点

  • SEMAR可显著减少髋部骨科硬件所致的CT金属伪影。
  • SEMAR在内置固定物患者中减少伪影的效果优于假体患者。
  • 所有AIDR 3D图像均不可诊断,SEMAR图像中仅16.7%-23.7%不可诊断。

核心结论

  • SEMAR算法显著减少CT图像中的金属伪影,对内置固定物患者的效果优于假体患者,并提供可靠的软组织衰减。

研究设计与样本

  • 回顾性纳入2015年2月至2019年10月153例髋部骨科硬件置入后行CT检查的患者,采用AIDR 3D和SEMAR算法重建,按硬件类型分为5组,由两名分别有21年和13年经验的阅片者盲法以5分制评估伪影程度和图像质量。

诊断标准与关键数值

  • 伪影程度和图像质量采用5分制评估;总体质量≤3分定义为不可诊断;SEMAR图像中不可诊断比例为16.7%-23.7%,主要见于假体患者(阅片者1:91.7%〔22/24〕;阅片者2:92.6%〔25/27〕)。

临床应用与阅片要点

  • SEMAR可减少髋部骨科硬件所致的CT金属伪影,但假体患者中仍有较高比例图像不可诊断,阅片时需注意。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the performance and reliability of the single-energy metal artifact reduction (SEMAR) algorithm in patients with different orthopedic hardware at the hips.

MATERIALS AND METHODS: A total of 153 patients with hip instrumentation who had undergone CT with adaptive iterative dose reduction (AIDR) 3D and SEMAR algorithms between February 2015 and October 2019 were included retrospectively. Patients were divided into 5 groups by the hardware type. Two readers with 21 and 13 years of experience blindly reviewed all image sets and graded the extent of artifacts and imaging quality using 5-point scales. To evaluate reliability, the mean densities and image noises were measured at the urinary bladder, veins, and fat in images with artifacts and the reference images.

RESULTS: No significant differences were found in the mean densities of the urinary bladder, veins, and fat between the SEMAR images with artifacts (7.57 ± 9.49, 40.29 ± 23.07, 86.78 ± 38.34) and the reference images (7.77 ± 6.2, 40.27 ± 8.66, 89.10 ± 20.70) (P = .860, .994, .392). Image noises of the urinary bladder in the SEMAR images with artifacts (14.25 ± 4.50) and the SEMAR reference images (9.69 ± 1.29) were significantly higher than those in the AIDR 3D reference images (9.11 ± 1.12) (P < .001; P < .001). All AIDR 3D images were non-diagnostic (overall quality ≤ 3) and less than a quarter of the SEMAR images were non-diagnostic (16.7-23.7%), mainly in patients with prostheses [reader 1: 91.7% (22/24); reader 2: 92.6% (25/27)].

CONCLUSION: The SEMAR algorithm significantly reduces metal artifacts in CT images, more in patients with internal fixations than in patients with prostheses, and provides reliable attenuation of soft tissues.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Chen YH, Lu CH, Chen YJ, et al. Reliability and benefits of single-energy projection-based metallic artifact reduction (SEMAR) in the different orthopedic hardware for the hip. Skeletal Radiol. 2022. PMID: 35347404. doi:10.1007/s00256-022-04040-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。