文献速递腹部技术与安全US

使用沉浸式虚拟现实模拟确保对比增强超声能力

Using Immersive Virtual Reality Simulation to Ensure Competence in Contrast-Enhanced Ultrasound.
PubMed 文献 · Ultrasound Med Biol · 2022-02-25

本研究开发了一种沉浸式虚拟现实模拟测试,用于评估对比增强超声(CEUS)核心能力,并依据Messick框架收集效度证据。测试模拟一位局灶性肝病变患者的CEUS检查,侧重造影前准备。25名不同CEUS经验的医生参与,最终23项测试条目具有良好的内部信度(Cronbach's α=0.85)和区分能力,假阳性和假阴性风险分别为9.1%和23.6%,可作为监督下临床培训前的认证工具。

要点

  • 沉浸式虚拟现实模拟测试包含23个条目,Cronbach's α=0.85,内部信度良好。
  • 测试假阳性风险9.1%,假阴性风险23.6%,可用于CEUS监督临床培训前认证。
  • 测试模拟局灶性肝病变的CEUS检查,侧重造影前准备环节。

核心结论

  • 开发的沉浸式虚拟现实模拟测试具有良好内部信度和区分能力,假阳性与假阴性风险可接受,可作为CEUS监督临床培训前的认证工具。

研究设计与样本

  • 研究由IVR软件专家与CEUS及医学教育临床专家共同开发测试,模拟一位局灶性肝病变患者的CEUS检查并侧重造影前准备;招募25名不同CEUS经验的医生作为测试参与者,依据Messick框架收集效度证据并建立合格/不合格标准。

诊断标准与关键数值

  • 最终测试包含23个测试条目,内部信度Cronbach's α=0.85;假阳性风险9.1%,假阴性风险23.6%。

临床应用与阅片要点

  • 该测试可在监督下临床培训前用于CEUS能力认证,模拟场景为局灶性肝病变的CEUS检查,侧重造影前准备。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Contrast-enhanced ultrasound (CEUS) is used in various medical specialties as a diagnostic imaging tool and for procedural guidance. Experience in the procedure is currently attained via supervised clinical practice that is challenged by patient availability and risks. Prior simulation-based training and subsequent assessment could improve and ensure competence before performance on patients, but no simulator currently exists. Immersive virtual reality (IVR) is a new promising simulation tool that can replicate complex interactions and environments that are unfeasible to achieve by traditional simulators. This study was aimed at developing an IVR simulation-based test for core CEUS competencies and gathering validity evidence for the test in accordance with Messick's framework. The test was developed by IVR software specialists and clinical experts in CEUS and medical education and imitated a CEUS examination of a patient with a focal liver lesion with emphasis on the pre-contrast preparations. Twenty-five medical doctors with varying CEUS experience were recruited as test participants, and their results were used to analyze test quality and to establish a pass/fail standard. The final test of 23 test items had good internal reliability (Cronbach's α = 0.85) and discriminatory abilities. The risks of false positives and negatives (9.1% and 23.6%, respectively) were acceptable for the test to be used as a certification tool prior to supervised clinical training in CEUS.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Jacobsen N, Larsen JD, Falster C, et al. Using Immersive Virtual Reality Simulation to Ensure Competence in Contrast-Enhanced Ultrasound. Ultrasound Med Biol. 2022. PMID: 35227531. doi:10.1016/j.ultrasmedbio.2022.01.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。