影像组学特征在慢性阻塞性肺疾病评估中的价值:一项前瞻性研究
这项前瞻性研究纳入197例接受高分辨率胸部CT的患者,探讨17个影像组学特征在评估COPD肺功能、健康状况和急性加重中的价值。多因素校正后,影像组学特征与FEV1占预计值百分比、FEV1/FVC、mMRC和SGRQ相关;随访1年时original_10thpercentile与mMRC变化相关,original_10thpercentile、original_elongation、original_sphericity和original_glv与SGRQ变化相关。Original_flatness与急性加重相关,并可提高其他模型对急性加重的预测性能。影像组学特征与气流受限、健康状况和COPD急性加重独立相关,在COPD评估中显示出前景。
要点
- 多因素校正后,影像组学特征与FEV1占预计值百分比、FEV1/FVC、mMRC和SGRQ显著相关。
- 随访1年时original_10thpercentile与mMRC变化相关。
- Original_flatness与急性加重相关,并可提高其他模型对急性加重的预测性能。
核心结论
- 影像组学特征与COPD气流受限、健康状况和急性加重独立相关,在COPD评估中显示出前景。
研究设计与样本
- 前瞻性研究纳入197例患者,于2009年至2011年间接受高分辨率胸部CT检查。
- 从胸部CT图像中选取17个影像组学特征,探讨影像组学在COPD评估中的适用性。
- 基线及1年随访时收集肺功能检查、mMRC、SGRQ、6分钟步行试验和急性加重情况。
- 采用线性与逻辑多因素分析评估影像组学特征与肺功能、健康状况和急性加重的关系。
诊断标准与关键数值
- 基线时多因素校正后,影像组学特征与FEV1占预计值百分比、FEV1/FVC、mMRC和SGRQ显著相关。
- 1年随访时,original_10thpercentile与mMRC变化相关。
- 1年随访时,original_10thpercentile、original_elongation、original_sphericity和original_glv与SGRQ变化相关。
- Original_flatness与急性加重相关,并可提高其他模型对急性加重的预测性能。
- 无影像组学特征与6分钟步行试验相关。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To investigate whether radiomic features could supply additional information in the assessment of lung function, health status, and exacerbation of chronic obstructive pulmonary disease (COPD).
MATERIALS AND METHODS: This prospective study enrolled 197 patients who underwent high-resolution chest computed tomography (CT) between 2009 and 2011. A total of 17 radiomic features from chest CT images were selected to explore the applicability of radiomics in the evaluation of COPD. Spirometric lung function testing, modified Medical Research Council (mMRC), St George's respiratory questionnaire (SGRQ), 6-minute walk test (6MWT), and exacerbations were collected at baseline and 1-year follow-up. The relationships of radiomic features, lung function, health status, and exacerbation were assessed using linear and logistic multivariate analyses.
RESULTS: At baseline visit, radiomic features were significantly associated with forced expiratory volume in 1 second percent of predicted (FEV1 % predicted), FEV1/forced vital capacity (FVC), mMRC, and SGRQ after multivariate adjustment. At 1-year follow-up, original_10thpercentile was associated with mMRC change, and original_10thpercentile, original_elongation, original_sphericity, and original_glv were associated with SGRQ change. Original_flatness was associated with exacerbation and can improve the prediction performance of other models for exacerbation. No radiomic features correlated with the 6MWT.
CONCLUSION: Radiomic features were associated with airflow obstruction, health status, and exacerbation of COPD independent of other factors, showing promise in the assessment of COPD.
引用
- Yang K, Yang Y, Kang Y, et al. The value of radiomic features in chronic obstructive pulmonary disease assessment: a prospective study. Clin Radiol. 2022. PMID: 35346461. doi:10.1016/j.crad.2022.02.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。