文献速递乳腺MR

使用多频带敏感编码与CAIPIRINHA方法加速乳腺扩散加权成像:3 T下的临床经验

Accelerated Breast Diffusion-weighted Imaging Using Multiband Sensitivity Encoding with the CAIPIRINHA Method: Clinical Experience at 3 T.
PubMed 文献 · Radiol Imaging Cancer · 2022-01-01

这项前瞻性研究纳入38例乳腺癌女性,在临床3 T乳腺MRI中加做多频带敏感编码扩散加权成像(MB SENSE DWI),并与常规扩散加权平面回波成像(cDWI)进行定量与定性比较。结果显示两种方法肿瘤ADC、CNR及SI无显著差异,MB SENSE DWI在37%的图像中被优先选择,最常见原因是脂肪抑制更好。

要点

  • MB SENSE DWI与cDWI的肿瘤ADC测量一致性良好(组内相关系数0.87,95%CI 0.75–0.94)。
  • 两种方法肿瘤ADC、CNR及SI测量值无显著差异(P值分别为.50、.17、.23)。
  • 51%的图像(58/114)两种方法图像质量相当,MB SENSE DWI被优先选择的比例高于cDWI(37% [42/114] vs 12% [14/114];P < .001)。

核心结论

  • MB SENSE可用于加速乳腺DWI采集时间,而不损害图像质量或定量ADC测量的保真度。

研究设计与样本

  • 前瞻性研究(ClinicalTrials.gov注册号NCT03607552),2018年7月至2019年7月招募乳腺癌女性38例(中位年龄48岁,范围28–83岁),在临床3 T乳腺MRI检查中加做MB SENSE DWI,并与cDWI进行定量和定性评估。

关键影像表现/征象

  • MB SENSE DWI被优先选择的比例高于cDWI(37% [42/114] vs 12% [14/114];P < .001),最常见原因是脂肪抑制更好。
  • 51%的图像(58/114)中cDWI与MB SENSE DWI图像质量被认为相当。

诊断标准与关键数值

  • 肿瘤ADC在cDWI与MB SENSE DWI之间总体一致性良好(组内相关系数0.87 [95% CI: 0.75, 0.94])。
  • 肿瘤ADC中位数cDWI 0.93 × 10-3 mm2/sec vs MB SENSE DWI 0.87 × 10-3 mm2/sec(P = .50)。
  • CNR cDWI 2.2 vs MB SENSE DWI 2.3(P = .17)。
  • SI cDWI 9.2 vs MB SENSE DWI 9.2(P = .23)。

临床应用与阅片要点

  • MB SENSE可用于加速乳腺DWI采集,同时保持与cDWI相当的图像质量和ADC测量保真度。
  • MB SENSE DWI在多数图像中被认为图像质量等同或更优,最常见优势为脂肪抑制更好。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To examine the clinical value of multiband (MB) sensitivity encoding (SENSE)-accelerated diffusion-weighted imaging (DWI) for breast imaging by performing quantitative and qualitative comparisons with conventional diffusion-weighted echo-planar imaging, or conventional DWI (cDWI). Materials and Methods In this prospective study (ClinicalTrials.gov identifier NCT03607552), women with breast cancer were recruited from July 2018 to July 2019 to undergo additional MB SENSE DWI during clinical 3-T breast MRI examinations. The cDWI and MB SENSE DWI acquisitions were assessed both quantitatively and qualitatively. Regions of interest were defined for tumorous and normal tissue, and the tumor apparent diffusion coefficient (ADC), contrast-to-noise ratio (CNR), and signal index (SI) were calculated for both DWI methods. Three readers independently reviewed the two acquisitions side by side and provided relative image quality scores. Tumor ADC, CNR, and SI measures were compared between cDWI and MB SENSE DWI acquisitions by using a paired t test, and reader preferences were evaluated by using the sign test. Results The study included 38 women (median age, 48 years; range, 28-83 years). Overall agreement was good between cDWI and MB SENSE DWI tumor ADC measures (intraclass correlation coefficient, 0.87 [95% CI: 0.75, 0.94]), and no differences were evident in the ADC (median, 0.93 × 10-3 mm2/sec vs 0.87 ×10-3 mm2/sec; P = .50), CNR (2.2 vs 2.3; P = .17), or SI (9.2 vs 9.2; P = .23) measurements. The image quality of cDWI and MB SENSE DWI acquisitions were considered equal for 51% of images (58 of 114), whereas MB SENSE DWI was preferred more often than cDWI (37% [42 of 114] vs 12% [14 of 114]; P < .001). The preference for MB SENSE DWI was most often attributed to better fat suppression. Conclusion MB SENSE can be used to accelerate breast DWI acquisition times without compromising the image quality or the fidelity of quantitative ADC measurements. Keywords: MR-Diffusion-weighted Imaging, Breast, Comparative Studies, Technology Assessment Clinical trial registration no. NCT03607552 © RSNA, 2022.

来源:Radiol Imaging Cancer,查看原文。版权归原作者所有。

引用

  1. Biswas D, Hippe DS, Wang Y, et al. Accelerated Breast Diffusion-weighted Imaging Using Multiband Sensitivity Encoding with the CAIPIRINHA Method: Clinical Experience at 3 T. Radiol Imaging Cancer. 2022. PMID: 35029517. doi:10.1148/rycan.210063

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。