文献速递妇产影像腹部MR

子宫内膜癌MRI表现对比分析:子宫内膜样腺癌、浆液性癌与透明细胞癌的鉴别

A comparative analysis of MRI findings in endometrial cancer: differentiation between endometrioid adenocarcinoma, serous carcinoma, and clear cell carcinoma.
PubMed 文献 · Eur Radiol · 2022-01-21

回顾274例经组织病理学确诊的子宫内膜癌患者术前MRI,比较子宫内膜样癌(231例)、浆液性癌(25例)和透明细胞癌(18例)的影像表现。透明细胞癌最大径和ADC值显著大于子宫内膜样癌和浆液性癌;浆液性癌腹膜播散和异常腹水更常见,浆液性癌与透明细胞癌信号不均匀更常见。

要点

  • 透明细胞癌最大径(55.6±34.7 mm)和ADC值(1.11±0.21×10⁻³ mm²/s)高于子宫内膜样癌和浆液性癌。
  • 浆液性癌腹膜播散(16% vs 0%)和异常腹水更常见于子宫内膜样癌。
  • 浆液性癌和透明细胞癌T1、T2及增强T1信号不均匀较子宫内膜样癌更常见。

核心结论

  • 浆液性癌常表现为信号不均匀伴腹膜播散和异常腹水;透明细胞癌倾向于更大肿瘤尺寸、更高ADC值、浸润性生长方式、信号不均匀和异常腹水。

研究设计与样本

  • 回顾性比较研究,纳入274例连续患者(231例子宫内膜样癌、25例浆液性癌、18例透明细胞癌),均为组织病理学确诊并于子宫切除术前接受MRI检查,回顾性阅片比较三种病理类型的MRI表现。

关键影像表现/征象

  • 透明细胞癌最大径55.6±34.7 mm,子宫内膜样癌39.3±21.6 mm,浆液性癌39.4±26.8 mm(p<0.05)。
  • 浆液性癌腹膜播散16% vs 子宫内膜样癌0%(p<0.01)。
  • 浆液性癌扩散加权成像信号不均匀61% vs 子宫内膜样癌32%(p<0.05)。
  • 异常腹水浆液性癌12%、透明细胞癌11%、子宫内膜样癌0%。
  • T1加权信号不均匀浆液性癌28%、透明细胞癌50%、子宫内膜样癌9%;T2加权64%、72%、36%;脂肪抑制钆增强T1加权80%、90%、46%(p<0.05)。

诊断标准与关键数值

  • 透明细胞癌ADC值1.11±0.21×10⁻³ mm²/s,子宫内膜样癌0.84±0.17×10⁻³ mm²/s,浆液性癌0.86±0.16×10⁻³ mm²/s(p<0.01)。
  • 透明细胞癌浸润性生长方式33% vs 子宫内膜样癌6%(p<0.01)。

临床应用与阅片要点

  • 阅片时注意肿瘤最大径和ADC值,透明细胞癌倾向于更大尺寸和更高ADC值。
  • 关注腹膜播散、异常腹水及T1、T2、增强T1和DWI信号不均匀,浆液性癌和透明细胞癌较子宫内膜样癌更常见。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To assess the magnetic resonance imaging (MRI) findings of endometrial cancers and to reveal the differences between endometrioid carcinoma (EC), serous carcinoma (SC), and clear cell carcinoma (CCC).

METHODS: In this study, 274 consecutive patients with histopathologically confirmed endometrial cancer (231 ECs, 25 SCs, and 18 CCCs) who underwent MRI before hysterectomy were enrolled. MRI images were retrospectively reviewed and compared between the three pathologies.

RESULTS: The maximum diameters (55.6 ± 34.7 vs. 39.3 ± 21.6 vs. 39.4 ± 26.8 mm) (p < 0.05) and apparent diffusion coefficient (ADC) values (1.11 ± 0.21 vs. 0.84 ± 0.17 vs. 0.86 ± 0.16 × 10-3 mm2/s) (p < 0.01) were significantly greater in CCCs than in ECs and SCs, respectively. Infiltrative growth pattern (33% vs. 6%) (p < 0.01) was more frequent in CCCs than in ECs. Peritoneal dissemination (16% vs. 0%) (p < 0.01) and heterogeneous signal on diffusion-weighted (61% vs. 32%) (p < 0.05) images were more frequent in SCs than in ECs, respectively. Abnormal ascites (12% vs. 11% vs. 0%) and heterogeneous signal on T1-weighted (28% vs. 50% vs. 9%), T2-weighted (64% vs. 72% vs. 36%), and fat-suppressed gadolinium-enhanced T1-weighted (80% vs. 90% vs. 46%) images were more frequent in SCs and CCCs than in ECs, respectively (p < 0.05).

CONCLUSIONS: SCs frequently exhibited a heterogeneous signal with peritoneal dissemination and abnormal ascites. Alternatively, CCCs tended to have a larger tumor size and higher ADC values with an infiltrative growth pattern, heterogeneous signal, and abnormal ascites.

KEY POINTS: • SCs tend to have a heterogeneous signal intensity with peritoneal dissemination and abnormal ascites compared to ECs. • CCCs tend to have a heterogeneous signal intensity with an infiltrative growth pattern and abnormal ascites compared to ECs. • CCCs have a larger tumor size and higher ADC values compared to ECs and SCs.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Mori T, Kato H, Kawaguchi M, et al. A comparative analysis of MRI findings in endometrial cancer: differentiation between endometrioid adenocarcinoma, serous carcinoma, and clear cell carcinoma. Eur Radiol. 2022. PMID: 35061079. doi:10.1007/s00330-021-08512-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。