生成对抗网络与双能减影在胸部X线肺结节检测中的骨抑制效果比较
本研究纳入111例成人(49例患者共83个肺结节),以胸部CT为参考,比较基于生成对抗网络的深度学习骨抑制成像(BSp-DL)与双能技术骨减影成像(BSt-DE)对放射科医师在胸部X线片上检测肺结节性能的影响。结果显示,BSp-DL在结节层面和个体层面的性能均优于标准CXR,与BSt-DE相当;BSt-DE在检测周围型和亚厘米结节方面优于BSp-DL。结论认为BSp-DL可改善放射科医师检测肺结节的性能,但小和周围型结节的显示仍需进一步技术改进。
要点
- BSp-DL在个体层面检测肺结节的性能优于标准CXR,与BSt-DE相当。
- BSt-DE和BSp-DL在检测与骨骼重叠的结节或位于上/中肺带的结节方面均优于标准CXR。
- BSt-DE在检测周围型和亚厘米结节方面优于BSp-DL。
核心结论
- 基于GAN的骨抑制成像(BSp-DL)表现与双能骨减影成像(BSt-DE)相当,可改善放射科医师在胸部X线片上检测肺结节的性能;但为更好地显示小和周围型结节,仍需进一步技术改进。
研究设计与样本
- 共纳入111例成人(其中49例患者含83个肺结节),所有受试者均接受双能技术胸部X线摄影和胸部CT检查;以CT为参考,两名独立放射科医师在三次阅读 session(标准CXR、BSt-DE CXR、BSp-DL CXR)中评估肺结节的存在与否。
诊断标准与关键数值
- 结节层面:BSt-DE的AUAFROC在读者1和读者2分别为0.996和0.976,BSp-DL分别为0.981和0.958,均优于标准CXR(分别为0.907和0.808;p ≤ 0.005)。个体层面:BSp-DL的AUROC在读者1和读者2分别为0.984和0.931,优于标准CXR(分别为0.915和0.798;p ≤ 0.011),与BSt-DE(分别为0.988和0.974)相当(p ≥ 0.064)。BSt-DE和BSp-DL在检测与骨骼重叠的结节(p < 0.017)或位于上/中肺带的结节(p < 0.017)方面均优于标准CXR。BSt-DE在检测周围型和亚厘米结节方面优于BSp-DL(p < 0.017)。
临床应用与阅片要点
- BSp-DL可作为改善胸部X线片肺结节检测的骨抑制方法,其性能与BSt-DE相当;对于小和周围型结节,BSt-DE的显示优于BSp-DL。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To compare the effects of bone suppression imaging using deep learning (BSp-DL) based on a generative adversarial network (GAN) and bone subtraction imaging using a dual energy technique (BSt-DE) on radiologists' performance for pulmonary nodule detection on chest radiographs (CXRs).
MATERIALS AND METHODS: A total of 111 adults, including 49 patients with 83 pulmonary nodules, who underwent both CXR using the dual energy technique and chest CT, were enrolled. Using CT as a reference, two independent radiologists evaluated CXR images for the presence or absence of pulmonary nodules in three reading sessions (standard CXR, BSt-DE CXR, and BSp-DL CXR). Person-wise and nodule-wise performances were assessed using receiver-operating characteristic (ROC) and alternative free-response ROC (AFROC) curve analyses, respectively. Subgroup analyses based on nodule size, location, and the presence of overlapping bones were performed.
RESULTS: BSt-DE with an area under the AFROC curve (AUAFROC) of 0.996 and 0.976 for readers 1 and 2, respectively, and BSp-DL with AUAFROC of 0.981 and 0.958, respectively, showed better nodule-wise performance than standard CXR (AUAFROC of 0.907 and 0.808, respectively; p ≤ 0.005). In the person-wise analysis, BSp-DL with an area under the ROC curve (AUROC) of 0.984 and 0.931 for readers 1 and 2, respectively, showed better performance than standard CXR (AUROC of 0.915 and 0.798, respectively; p ≤ 0.011) and comparable performance to BSt-DE (AUROC of 0.988 and 0.974; p ≥ 0.064). BSt-DE and BSp-DL were superior to standard CXR for detecting nodules overlapping with bones (p < 0.017) or in the upper/middle lung zone (p < 0.017). BSt-DE was superior (p < 0.017) to BSp-DL in detecting peripheral and sub-centimeter nodules.
CONCLUSION: BSp-DL (GAN-based bone suppression) showed comparable performance to BSt-DE and can improve radiologists' performance in detecting pulmonary nodules on CXRs. Nevertheless, for better delineation of small and peripheral nodules, further technical improvements are required.
引用
- Bae K, Oh DY, Yun ID, et al. Bone Suppression on Chest Radiographs for Pulmonary Nodule Detection: Comparison between a Generative Adversarial Network and Dual-Energy Subtraction. Korean J Radiol. 2022. PMID: 34983100. doi:10.3348/kjr.2021.0146
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。