轻度创伤性脑损伤伴脑震荡后综合征患者的髓鞘含量:多动态多回波序列定量评估
研究纳入41例连续轻度创伤性脑损伤伴脑震荡后综合征患者和29例对照,采用多动态多回波序列定量髓鞘体积分数。患者双侧大脑白质平均髓鞘体积分数低于对照,胼胝体和脑干总髓鞘体积降低,除白质总髓鞘体积与言语学习测验(延迟回忆)相关外,髓鞘体积参数与神经心理测验评分无显著相关。
要点
- mTBI伴PCS患者双侧大脑白质平均髓鞘体积分数低于对照(25.2% vs 26.8%,p=0.004)。
- 胼胝体和脑干的总髓鞘体积在mTBI伴PCS患者中降低,提示萎缩性改变。
- 除白质总髓鞘体积与言语学习测验延迟回忆相关外,髓鞘体积与神经心理评分无显著相关。
核心结论
- 基于MDME序列定量的髓鞘体积分数在mTBI伴PCS患者双侧大脑白质降低,胼胝体和脑干总髓鞘体积因萎缩性改变而降低。
研究设计与样本
- 研究纳入2016年10月至2018年4月间接受含MDME序列MRI的41例连续mTBI伴PCS患者和29例对照,基于三维T1脑分割分析双侧大脑白质、灰质、胼胝体和脑干的平均髓鞘体积分数。
关键影像表现/征象
- mTBI伴PCS患者双侧大脑白质平均髓鞘体积分数中位数25.2%(四分位距22.6%-26.4%),低于对照的26.8%(25.6%-27.8%)(p=0.004)。
- mTBI伴PCS患者胼胝体感兴趣区髓鞘体积中位数1.87 cm3(1.70-2.05 cm3),低于对照的2.21 cm3(1.86-3.46 cm3)(p=0.003)。
- mTBI伴PCS患者脑干感兴趣区髓鞘体积中位数9.98 cm3(9.45-11.00 cm3),低于对照的11.05 cm3(10.10-11.53 cm3)(p=0.015)。
- mTBI伴PCS患者胼胝体总髓鞘体积中位数0.45 cm3(0.39-0.48 cm3),低于对照的0.48 cm3(0.45-0.54 cm3)(p=0.004)。
- mTBI伴PCS患者脑干总髓鞘体积中位数1.45 cm3(1.28-1.59 cm3),低于对照的1.54 cm3(1.42-1.67 cm3)(p=0.042)。
诊断标准与关键数值
- 双侧大脑白质平均髓鞘体积分数:mTBI伴PCS患者25.2%(22.6%-26.4%)vs 对照26.8%(25.6%-27.8%),p=0.004。
- 胼胝体感兴趣区髓鞘体积:mTBI伴PCS患者1.87 cm3(1.70-2.05 cm3)vs 对照2.21 cm3(1.86-3.46 cm3),p=0.003。
- 脑干感兴趣区髓鞘体积:mTBI伴PCS患者9.98 cm3(9.45-11.00 cm3)vs 对照11.05 cm3(10.10-11.53 cm3),p=0.015。
- 胼胝体总髓鞘体积:mTBI伴PCS患者0.45 cm3(0.39-0.48 cm3)vs 对照0.48 cm3(0.45-0.54 cm3),p=0.004。
- 脑干总髓鞘体积:mTBI伴PCS患者1.45 cm3(1.28-1.59 cm3)vs 对照1.54 cm3(1.42-1.67 cm3),p=0.042。
临床应用与阅片要点
- mTBI伴PCS患者双侧大脑白质平均髓鞘体积分数减低,胼胝体和脑干总髓鞘体积减低,但髓鞘体积参数与神经心理测验评分多无显著相关。
- 双侧大脑白质总髓鞘体积与言语学习测验(延迟回忆)呈相关(r=0.425;p=0.048)。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: This study aimed to explore the myelin volume change in patients with mild traumatic brain injury (mTBI) with post-concussion syndrome (PCS) using a multidynamic multiecho (MDME) sequence and automatic whole-brain segmentation.
MATERIALS AND METHODS: Forty-one consecutive mTBI patients with PCS and 29 controls, who had undergone MRI including the MDME sequence between October 2016 and April 2018, were included. Myelin volume fraction (MVF) maps were derived from the MDME sequence. After three dimensional T1-based brain segmentation, the average MVF was analyzed at the bilateral cerebral white matter (WM), bilateral cerebral gray matter (GM), corpus callosum, and brainstem. The Mann-Whitney U-test was performed to compare MVF and myelin volume between patients with mTBI and controls. Myelin volume was correlated with neuropsychological test scores using the Spearman rank correlation test.
RESULTS: The average MVF at the bilateral cerebral WM was lower in mTBI patients with PCS (median [interquartile range], 25.2% [22.6%-26.4%]) than that in controls (26.8% [25.6%-27.8%]) (p = 0.004). The region-of-interest myelin volume was lower in mTBI patients with PCS than that in controls at the corpus callosum (1.87 cm3 [1.70-2.05 cm3] vs. 2.21 cm3 [1.86-3.46 cm3]; p = 0.003) and brainstem (9.98 cm3 [9.45-11.00 cm3] vs. 11.05 cm3 [10.10-11.53 cm3]; p = 0.015). The total myelin volume was lower in mTBI patients with PCS than that in controls at the corpus callosum (0.45 cm3 [0.39-0.48 cm3] vs. 0.48 cm3 [0.45-0.54 cm3]; p = 0.004) and brainstem (1.45 cm3 [1.28-1.59 cm3] vs. 1.54 cm3 [1.42-1.67 cm3]; p = 0.042). No significant correlation was observed between myelin volume parameters and neuropsychological test scores, except for the total myelin volume at the bilateral cerebral WM and verbal learning test (delayed recall) (r = 0.425; p = 0.048).
CONCLUSION: MVF quantified from the MDME sequence was decreased at the bilateral cerebral WM in mTBI patients with PCS. The total myelin volumes at the corpus callosum and brainstem were decreased in mTBI patients with PCS due to atrophic changes.
引用
- Yoo RE, Choi SH, Youn SW, et al. Myelin Content in Mild Traumatic Brain Injury Patients with Post-Concussion Syndrome: Quantitative Assessment with a Multidynamic Multiecho Sequence. Korean J Radiol. 2022. PMID: 35029073. doi:10.3348/kjr.2021.0253
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。