改良钙去除算法在颈内动脉双能CT评估中的效果评价
回顾性纳入46例患者共154个钙化颈内动脉节段,以DSA为参考标准,比较混合图像与基于改良三物质分解算法的虚拟无钙图像评估狭窄程度的表现。VNCa图像在全部节段与DSA无显著差异,C3-C5及C6节段混合图像高估狭窄,VNCa与DSA的一致性ICC为0.86-0.97,高于混合图像的0.68-0.96。
要点
- C3-C5及C6节段混合图像狭窄程度显著高于DSA,VNCa图像与DSA无显著差异。
- VNCa与DSA的ICC为0.86-0.97,混合图像与DSA的ICC为0.68-0.96。
- 改良三物质分解DECT去钙算法在颈内动脉狭窄评估中表现有前景,尤其C3-C5和C6节段。
核心结论
- 基于改良三物质分解算法的DECT去钙软件在颈内动脉狭窄评估中表现有前景,尤其对C3-C5和C6节段。
研究设计与样本
- 回顾性研究,纳入46例患者(38名男性,67±8岁)共154个钙化颈内动脉节段,包括C1-C2(59个)、C3-C5(63个)、C6(24个)和C7(8个);重建混合图像和改良DECT算法的虚拟无钙(VNCa)图像,以DSA为参考标准。
关键影像表现/征象
- 混合图像在C3-C5节段狭窄程度为30%±17.9%,DSA为23.0%±16.9%(p=0.026)。
- 混合图像在C6节段狭窄程度为38.3%±15.4%,DSA为28.5%±13.3%(p=0.023)。
- VNCa图像在所有节段与DSA图像狭窄程度均无显著差异(所有p>0.05)。
诊断标准与关键数值
- VNCa与DSA图像ICC为0.86-0.97,混合图像与DSA图像ICC为0.68-0.96。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the performance of a dual-energy (DE) calcium removal software based on a modified three-material decomposition algorithm in assessing the stenosis of the internal carotid artery (ICA) in comparison with mixed images using digital subtraction angiography (DSA) as the reference standard.
METHODS: Forty-six patients (38 men; 67±8 years old), including 154 calcified ICA segments C1-C2 (59), C3-C5 (63), C6 (24), and C7 (8), were recruited in this retrospective study. Mixed images and virtual non-calcium (VNCa) images using the modified dual-energy computed tomography (DECT) algorithm were reconstructed. The differences between VNCa and DSA images vs. mixed and DSA images of degree of stenosis were compared. The intraclass correlation coefficient (ICC) was used for assessing the agreement between VNCa, mixed images, and DSA.
RESULTS: The degree of stenosis differed significantly between mixed and DSA images in the C3-C5 (30%±17.9% vs. 23.0%±16.9%, p = 0.026) and C6 (38.3%±15.4% vs. 28.5%±13.3%, p = 0.023) segments. The stenosis of VNCa images showed no significant difference with DSA images in all segments (all p > 0.05). The ICCs between VNCa and DSA images (0.86-0.97) were higher than those between the mixed and DSA images (0.68-0.96) in all segments.
CONCLUSION: The performance of a modified three-material decomposition DECT algorithm for calcium removal in ICA stenosis evaluation, particularly for the C3-C5 and C6 ICA segments, was promising.
引用
- Chen J, Niu Z, Zhan K, et al. Evaluation of Modified Calcium Removal Algorithm in dual energy CT of Internal Carotid Artery. Eur J Radiol. 2021. PMID: 34773829. doi:10.1016/j.ejrad.2021.109927
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。