死后全身对比增强微焦点CT与高场磁共振成像在人类胎儿中的比较
本研究比较了微焦点CT(micro-CT)与高场磁共振成像(HF-MRI,≥3 Tesla)在死后全身胎儿成像中的图像质量和诊断能力。胎儿解剖学专家对4例13-18孕周胎儿的56幅HF-MRI和56幅micro-CT图像进行定性评分,并手动分割三个器官评估观察者间变异。结果显示micro-CT在定性评估所有组成部分得分更高,观察者间变异更低,信噪比和对比噪声比更高。
要点
- micro-CT最高各向同性分辨率为22 µm,HF-MRI最高各向同性分辨率为137 µm,两者均达亚毫米体素。
- micro-CT在定性评估的所有组成部分得分均高于HF-MRI。
- micro-CT观察者间变异更低,信噪比和对比噪声比更高。
核心结论
- micro-CT在死后全身胎儿成像的定量和定性结果上均优于HF-MRI,提示micro-CT图像能提取更多诊断信息,作者认为micro-CT是早期妊娠替代传统胎儿尸检的优选成像方式。
研究设计与样本
- 研究比较micro-CT与HF-MRI的成像过程和图像质量,采用定性和定量评估;定性评估由胎儿解剖学专家对4例13-18孕周人类胎儿的56幅HF-MRI和56幅micro-CT图像评分,定量评估包括手动分割三个器官评估观察者间变异以及测定五个主要器官的信噪比和对比噪声比。
关键影像表现/征象
- micro-CT最高分辨率为22 µm(各向同性),HF-MRI最高分辨率为137 µm(各向同性),两者均达到亚毫米体素大小。
临床应用与阅片要点
- 作者认为micro-CT是早期妊娠替代传统胎儿尸检的优选成像方式,并且是死后成像服务中不可或缺的工具。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Although fetal autopsy is generally recommended to confirm or refute the antemortem diagnosis, parental acceptance of the procedure has fallen over time, mainly due to its invasiveness. Contrast-enhanced microfocus CT (micro-CT) and high-field magnetic resonance imaging (HF-MRI, ≥ 3 Tesla) have both been suggested as non-invasive alternatives to conventional fetal autopsy for fetuses < 20 weeks of gestation. The aim of this study was to compare these two modalities in postmortem whole-body fetal imaging.
METHODS: In this study, the imaging process and quality of micro-CT and HF-MRI were compared using both qualitative and quantitative assessments. For the qualitative evaluation, fetal anatomy experts scored 56 HF-MRI and 56 micro-CT images of four human fetuses aged 13-18 gestational weeks on two components: overall image quality and the ability to recognize and assess 21 anatomical structures. For the quantitative evaluation, participants segmented manually three organs with increasing complexity to assess interobserver variability. In addition, the signal-to-noise and contrast-to-noise ratios of five major organs were determined.
RESULTS: Both imaging techniques were able to reach submillimeter voxel size. The highest resolution of micro-CT was 22 µm (isotropic), while the highest resolution of HF-MRI was 137 µm (isotropic). The qualitative image assessment form was sent to 45 fetal anatomy experts, of whom 36 (80%) responded. It was observed that micro-CT scored higher on all components of the qualitative assessment compared with HF-MRI. In addition, the quantitative assessment showed that micro-CT had lower interobserver variability and higher signal-to-noise and contrast-to-noise ratios.
CONCLUSIONS: Our findings show that micro-CT outperforms HF-MRI in postmortem whole-body fetal imaging in terms of both quantitative and qualitative outcomes. Combined, these findings suggest that the ability to extract diagnostic information is greater when assessing micro-CT compared with HF-MRI images. We, therefore, believe that micro-CT is the preferred imaging modality as an alternative to conventional fetal autopsy for early gestation and is an indispensable tool in postmortem imaging services. © 2021 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Dawood Y, Honhoff C, van der Post AS, et al. Comparison of postmortem whole-body contrast-enhanced microfocus computed tomography and high-field magnetic resonance imaging of human fetuses. Ultrasound Obstet Gynecol. 2022. PMID: 34826157. doi:10.1002/uog.24827
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。