文献速递泌尿生殖腹部MR

肾脏肿瘤弥散加权磁共振成像衍生的ADC直方图参数联合患者特征与肿瘤体积鉴别嗜酸细胞瘤与肾细胞癌

Kidney tumor diffusion-weighted magnetic resonance imaging derived ADC histogram parameters combined with patient characteristics and tumor volume to discriminate oncocytoma from renal cell carcinoma.
PubMed 文献 · Eur J Radiol · 2021-10-30

这项前瞻性研究纳入39例肾脏肿瘤患者(32例肾细胞癌,7例嗜酸细胞瘤),评估全肿瘤ADC直方图参数联合肿瘤体积和患者特征鉴别嗜酸细胞瘤与肾细胞癌的能力。联合ADC标准差、熵、肿瘤体积和患者性别的回归模型ROC-AUC为0.91,敏感度86%,特异度84%;患者内ADC第25百分位数与熵差值联合的ROC-AUC为0.86,敏感度和特异度分别为86%和81%。作者认为该初步研究结果尚不足以支持临床使用该模型,但可促进进一步研究。

要点

  • 联合ADC标准差、熵、肿瘤体积和患者性别的模型鉴别嗜酸细胞瘤与肾细胞癌的ROC-AUC为0.91,敏感度86%,特异度84%。
  • 患者内ADC第25百分位数与熵差值联合的ROC-AUC为0.86,敏感度和特异度分别为86%和81%。
  • ADC标准差(p=0.008)、熵(p=0.010)、肿瘤体积(p=0.012)和患者性别(p=0.018)在肾细胞癌与嗜酸细胞瘤间差异显著。

核心结论

  • 联合ADC标准差和熵与肿瘤体积及患者性别的模型对鉴别嗜酸细胞瘤具有最高诊断价值;患者内ADC第25百分位数与熵差值虽准确性较低但也可用于鉴别;该初步研究结果尚不足以支持临床使用该模型,但可促进进一步研究。

研究设计与样本

  • 前瞻性研究,纳入39例患者(平均年龄65岁,范围28-79岁;女性9/39,23%)的39个肾脏肿瘤(肾细胞癌32/39,82%;嗜酸细胞瘤7/39,18%),于2014年11月至2018年6月行多参数MRI。

关键影像表现/征象

  • 勾画两个感兴趣区分别覆盖整个肿瘤体积和部分健康肾皮质。
  • ROI ADC图采用单指数模型计算,并计算ADC直方图分布参数。
  • ADC标准差、熵、肿瘤体积和患者性别在肾细胞癌与嗜酸细胞瘤间差异显著。

诊断标准与关键数值

  • 联合ADC标准差、熵、肿瘤体积和患者性别的回归模型:ROC-AUC 0.91,敏感度86%,特异度84%。
  • 患者内ADC第25百分位数与熵差值联合:ROC-AUC 0.86,敏感度86%,特异度81%。
  • ADC标准差p=0.008、熵p=0.010、肿瘤体积p=0.012、患者性别p=0.018在肾细胞癌与嗜酸细胞瘤间差异显著。
  • 患者内ADC第25百分位数差值p<0.01、熵差值p=0.030有统计学意义。

临床应用与阅片要点

  • 作者认为该初步研究结果尚不足以支持临床使用该模型,但可促进使用全肿瘤ADC直方图参数的进一步研究。

局限性

  • 作者指出该研究为初步研究,结果尚不足以支持临床使用该模型。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess the ability to discriminate oncocytoma from RCC based on a model using whole tumor ADC histogram parameters with additional use of tumor volume and patient characteristics.

METHOD: In this prospective study, 39 patients (mean age 65 years, range 28-79; 9/39 (23%) female) with 39 renal tumors (32/39 (82%) RCC and 7/39 (18%) oncocytoma) underwent multiparametric MRI between November 2014 and June 2018. Two regions of interest (ROIs) were drawn to cover both the entire tumor volume and a part of healthy renal cortex. ROI ADC maps were calculated using a mono-exponential model and ADC histogram distribution parameters were calculated. A logistic regression model was created using ADC histogram parameters, radiographic and patient characteristics that were significantly different between oncocytoma and RCC. A ROC curve of the model was constructed and the AUC, sensitivity and specificity were calculated. Furthermore, differences in intra-patient ADC histogram parameters between renal tumor and healthy cortex were calculated. A separate ROC curve was constructed to differentiate oncocytoma from RCC using statistically significant intra-patient parameter differences.

RESULTS: ADC standard deviation (p = 0.008), entropy (p = 0.010), tumor volume (p = 0.012), and patient sex (p = 0.018) were significantly different between RCC and oncocytoma. The regression model of these parameters combined had an ROC-AUC of 0.91 with a sensitivity of 86% and specificity of 84%. Intra-patient difference in ADC 25th percentile (p < 0.01) and entropy (p = 0.030) combined had a ROC-AUC of 0.86 with a sensitivity and specificity of 86%, and 81%, respectively.

CONCLUSION: A model combining ADC standard deviation and entropy with tumor volume and patient sex has the highest diagnostic value for discrimination of oncocytoma. Although less accurate, intra-patient difference in ADC 25th percentile and entropy between renal tumor and healthy cortex can also be used. Although the results of this preliminary study do not yet justify clinical use of the model, it does stimulate further research using whole tumor ADC histogram parameters.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. van Oostenbrugge TJ, Spenkelink IM, Bokacheva L, et al. Kidney tumor diffusion-weighted magnetic resonance imaging derived ADC histogram parameters combined with patient characteristics and tumor volume to discriminate oncocytoma from renal cell carcinoma. Eur J Radiol. 2021. PMID: 34768055. doi:10.1016/j.ejrad.2021.110013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。