前列腺深度学习加速T2加权成像:进一步加速并降低空间分辨率对图像质量的影响

Deep learning-accelerated T2-weighted imaging of the prostate: Impact of further acceleration with lower spatial resolution on image quality.
PubMed 文献 · Eur J Radiol · 2021-10-30

在前列腺MRI中比较标准T2WI、高分辨率加速T2WI及更低分辨率加速T2WI(均含常规与深度学习重建)的图像质量。46例连续患者显示,深度学习重建可改善加速T2WI图像质量;采用深度学习时,较低分辨率加速T2WI可在采集时间缩短75.5%的情况下获得与标准T2WI相似的图像质量。

要点

  • 深度学习重建可改善前列腺加速T2WI的图像质量。
  • 深度学习结合低分辨率加速T2WI可在采集时间缩短75.5%时获得与标准T2WI相似的图像质量。
  • 低分辨率加速T2WI联合深度学习时,噪声和整体图像质量评分低于标准T2WI。

核心结论

  • 深度学习有助于改善前列腺加速T2WI的图像质量;采用深度学习时,空间分辨率低于标准T2WI的加速T2WI可在采集时间大幅缩短(75.5%)的情况下获得相似的图像质量。

研究设计与样本

  • 对46例连续患者行前列腺MRI,采集标准T2WI(3分32秒)、高分辨率加速T2WI(1分06秒)和低分辨率加速T2WI(0.52分钟),后两者分别应用常规重建和深度学习重建,由两名放射科医师独立评估五组图像。

诊断标准与关键数值

  • T2-LRDL与T2-std在外周带和移行带的信噪比无差异,外周带中位数21.7 vs 22.6,移行带16.5 vs 17.3;T2-HRC和T2-LRC的前列腺与肌肉对比度显著低于T2-std;T2-HRDL噪声(中位数4.0 vs 4.5,P < 0.001)和整体图像质量(4.5 vs 5.0,P = 0.001)评分显著低于T2-std;T2-LRDL其他伪影评分显著低于T2-std(4.5 vs 5.0,P = 0.006);其余评估因素在T2-std与T2-HRDL或T2-LRDL之间无差异。

临床应用与阅片要点

  • 前列腺MRI加速T2WI可采用深度学习重建以改善图像质量;采用深度学习时,可选用低分辨率加速方案以大幅缩短采集时间,但需注意其噪声和整体图像质量评分低于标准T2WI。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare image quality in prostate MRI among standard T2-weighted imaging (T2-std), accelerated T2-weighted imaging (T2WI) with high resolution (T2-HR) and more accelerated T2WI with lower resolution (T2-LR) using both conventional reconstruction (C) and deep learning reconstruction (DL).

MATERIALS AND METHODS: In 46 consecutive patients, T2-std, T2-HR and T2-LR were acquired in 3:32 min, 1:06 min and 0.52 min, respectively. Both reconstruction techniques (C and DL) were applied to T2-HR and T2-LR. Five sets of images (T2-std, T2-HRC, T2-LRC, T2-HRDL, and T2-LRDL) for each patient were independently evaluated by two radiologists. Quantitative analysis including the signal-to-noise ratio (SNR) and contrast ratio (CR) and qualitative analysis with a 5-point scale for the sharpness of structures, ghosting or other artifacts, noise and overall image quality were performed.

RESULTS: The SNR was not different in either the peripheral zone (PZ) or transition zone (TZ) between T2-LRDL and T2-std with the median value of 21.7 versus 22.6 in PZ and 16.5 versus 17.3 in TZ, respectively. The CR between the prostate gland and muscle was significantly lower on T2-HRC and T2-LRC than on T2-std. Most of the evaluated factors showed significantly lower scores on T2-HRC and T2-LRC than on T2-std. Although noise and overall image quality on T2-HRDL and other artifacts on T2-LRDL were rated significantly lower than on T2-std (median value 4.0 versus 4.5, P < 0.001; 4.5 versus 5.0, P = 0.001; 4.5 versus 5.0, P = 0.006, respectively), other factors did not differ between T2-std and T2-HRDL or T2-LRDL.

CONCLUSION: DL is useful to improve image quality in accelerated T2WI of the prostate gland. Using DL, accelerated T2WI with lower spatial resolution than T2-std can be achieved with similar image quality in much shorter scan time (75.5% reduction in the acquisition time).