文献速递腹部US

二维剪切波弹性成像评估肝纤维化的诊断效能:重点探讨不同感兴趣区方法的影响

Diagnostic Performance of 2-D Shear Wave Elastography on the Evaluation of Hepatic Fibrosis with Emphasis on Impact of the Different Region-of-Interest Methods.
PubMed 文献 · Ultrasound Med Biol · 2021-10-27

本研究回顾性纳入83例接受二维剪切波弹性成像(2-D SWE)和瞬时弹性成像(TE)的患者,比较圆形、方形及多感兴趣区三种ROI方法的肝硬度值及其与TE的相关性。结果显示三种ROI法测值差异有统计学意义(p<0.001),但与TE均高度相关(r>0.7,p<0.001),诊断显著纤维化和肝硬化的AUC均较高且三种ROI方法间无显著差异。

要点

  • 三种ROI方法的肝硬度测值差异有统计学意义(p<0.001),但均与TE高度相关(r>0.7,p<0.001)。
  • 三种ROI方法诊断显著纤维化的AUC分别为0.841、0.820、0.840,诊断肝硬化为0.962、0.946、0.945。
  • 无论采用哪种ROI方法,2-D SWE诊断肝纤维化均有较高效能,AUC间无显著差异。

核心结论

  • 无论采用圆形ROI、方形ROI还是多ROI方法,2-D SWE诊断肝纤维化均有较高效能,不同ROI方法间AUC无显著差异。

研究设计与样本

  • 回顾性研究,纳入83例接受2-D SWE(圆形ROI、方形ROI、多ROI三种方法,每种方法测量肝硬度5次)和瞬时弹性成像(TE)的患者,比较各ROI法测值与TE的相关性及诊断效能。

诊断标准与关键数值

  • 圆形ROI、方形ROI、多ROI诊断显著纤维化的AUC分别为0.841、0.820、0.840。
  • 圆形ROI、方形ROI、多ROI诊断肝硬化的AUC分别为0.962、0.946、0.945。
  • 三种ROI方法间AUC无显著差异。
  • 各ROI法肝硬度测值与TE测值均高度相关(r>0.7,p<0.001)。

临床应用与阅片要点

  • 无论采用圆形ROI、方形ROI还是多ROI方法,2-D SWE诊断肝纤维化均有较高效能,AUC间无显著差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

The purpose of this study was to evaluate the impact of the different region-of-interest (ROI) methods of 2-D shear wave elastography (2-D SWE) on hepatic fibrosis diagnosis. In this retrospective study, 83 patients who underwent 2-D SWE with three ROI methods (a circle ROI, a box ROI and multiple ROIs in an elastogram) and transient elastography (TE) were included. Liver stiffness (LS) was measured five times with each ROI method. These LS values were compared, and their correlation with those obtained from TE was evaluated. The LS values obtained using the three different ROI methods differed statistically (p < 0.001). However, the LS values obtained using each ROI method of 2-D SWE were highly correlated with those obtained using TE (r > 0.7, p < 0.001). All three ROI methods of 2-D SWE had high areas under the receiver operating characteristic curve in diagnosing significant fibrosis and cirrhosis (0.841, 0.820 and 0.840, respectively; 0.962, 0.946 and 0.945, respectively). There were no significant differences in area under the receiver operating characteristic curve among the ROI methods of 2-D SWE. Regardless of the ROI method, 2-D SWE had high performance in diagnosing hepatic fibrosis.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Kim EM, Park JW, Lee SM, et al. Diagnostic Performance of 2-D Shear Wave Elastography on the Evaluation of Hepatic Fibrosis with Emphasis on Impact of the Different Region-of-Interest Methods. Ultrasound Med Biol. 2021. PMID: 34756464. doi:10.1016/j.ultrasmedbio.2021.09.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。