文献速递腹部MR

利用MRI信号强度比鉴别自身免疫性胰腺炎与胰腺导管腺癌

Use of MRI signal intensity ratio to differentiate between autoimmune pancreatitis and pancreatic ductal adenocarcinoma.
PubMed 文献 · Clin Radiol · 2021-10-29

回顾性分析21例自身免疫性胰腺炎(AIP)与27例胰腺导管腺癌(PDA)患者的MRI数据,测量T2WI、动脉期和延迟期胰腺病灶与同层竖脊肌的信号强度比(SIR)。AIP组T2WI SIR低于PDA组,动脉期和延迟期SIR高于PDA组,差异均有统计学意义(p<0.001),对应AUC分别为0.925、0.906和0.961。结论认为T2WI、动脉期和延迟期SIR可用于鉴别AIP与PDA。

要点

  • T2WI上病灶/竖脊肌SIR<1.21提示AIP,敏感度85.7%、特异度81.5%。
  • 动脉期SIR>1.01提示AIP,敏感度90.5%、特异度74.6%。
  • 延迟期SIR>1.08提示AIP,敏感度90.5%、特异度81.5%,AUC 0.961。

核心结论

  • T2WI、动脉期和延迟期图像上胰腺病灶与竖脊肌的信号强度比可用于鉴别自身免疫性胰腺炎与胰腺导管腺癌。

研究设计与样本

  • 回顾性分析21例自身免疫性胰腺炎和27例胰腺导管腺癌患者的MRI数据,测量T2WI、动脉期和延迟期胰腺病灶与同层竖脊肌的信号强度并计算SIR。

关键影像表现/征象

  • AIP组T2WI、动脉期、延迟期SIR均值分别为0.96、1.27、1.42。
  • PDA组T2WI、动脉期、延迟期SIR均值分别为1.35、0.80、0.91。
  • AIP与PDA两组SIR差异均有统计学意义(p<0.001)。

诊断标准与关键数值

  • T2WI SIR<1.21诊断AIP的敏感度85.7%、特异度81.5%,AUC 0.925。
  • 动脉期SIR>1.01诊断AIP的敏感度90.5%、特异度74.6%,AUC 0.906。
  • 延迟期SIR>1.08诊断AIP的敏感度90.5%、特异度81.5%,AUC 0.961。
  • T2WI与延迟期AUC差异无统计学意义(Z=0.778,p=0.436)。
  • 动脉期与延迟期AUC差异无统计学意义(Z=1.279,p=0.201)。

临床应用与阅片要点

  • 阅片时可测量T2WI、动脉期和延迟期胰腺病灶与同层竖脊肌信号强度并计算SIR辅助鉴别AIP与PDA。
  • 延迟期SIR>1.08诊断AIP的AUC最高(0.961),敏感度90.5%、特异度81.5%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To evaluate the accuracy of the lesion-to-erector spinae signal intensity ratio (SIR) on magnetic resonance imaging (MRI) for distinguishing autoimmune pancreatitis (AIP) from pancreatic ductal adenocarcinoma (PDA).

MATERIALS AND METHODS: The MRI data of 21 patients with AIP and 27 patients with PDA were analysed retrospectively, and the signal intensity in pancreatic lesions and erector spinae muscles at the same level on T2-weighted imaging (T2WI), arterial phase (AP) imaging, and delayed phase (DP) imaging was measured for calculation of SIRs.

RESULTS: The mean SIRs of the pancreatic lesions and erector spinae from T2WI, AP, and DP images of AIP patients were 0.96, 1.27, and 1.42, respectively, while those of PDA patients were 1.35, 0.80, and 0.91, respectively. The differences in the SIRs between the AIP and PDA groups were statistically significant (p<0.001), with corresponding area under curve (AUC) values of 0.925, 0.906, and 0.961, respectively. The optimal cut-off values for the SIRs on T2WI, AP and DP images were 1.21, 1.01, and 1.08, respectively. SIR values < 1.21 on T2WI, >1.01 on AP imaging, and >1.08 on DP imaging identified AIP with sensitivities of 85.7%, 90.5%, and 90.5%, respectively, and specificities of 81.5%, 74.6%, and 81.5%, respectively. The AUC values for SIRs did not differ significantly between T2WI and DP imaging or AP and DP imaging (Z = 0.778, p=0.436; Z = 1.279, p=0.201).

CONCLUSION: The SIRs of pancreatic lesions and erector spinae on T2WI, AP, and DP images can be used to differentiate AIP from PDA.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Lu S, Liang J, Liao S, et al. Use of MRI signal intensity ratio to differentiate between autoimmune pancreatitis and pancreatic ductal adenocarcinoma. Clin Radiol. 2021. PMID: 34756699. doi:10.1016/j.crad.2021.10.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。