文献速递技术与安全PETCT

68Ga-DOTATATE PET/CT:最佳标准化摄取值(SUV)内部参考

68Ga-DOTATATE PET/CT: The Optimum Standardized Uptake Value (SUV) Internal Reference.
PubMed 文献 · Acad Radiol · 2020-10-21

该研究回顾性分析180例神经内分泌肿瘤患者的68Ga-DOTATATE PET/CT图像,测量肝脏和脾脏的体重归一化SUV(SUVbw)与瘦体重归一化SUV(SUL)。结果显示SUL方差显著低于SUVbw,肝脏SUL方差最低(3.69%±1.25%)。结论认为SUL较SUVbw更可重复、变异更小,肝脏SUL是最佳内部参考。

要点

  • 肝脏和脾脏SUL方差均显著低于SUVbw(P<0.0001)。
  • 肝脏SUVbw和SUL方差均显著低于脾脏对应值。
  • 肝脏SUL方差最低(3.69%±1.25%),为最佳内部参考。

核心结论

  • SUL较SUVbw在DOTA PET/CT中更可重复、变异更小,是更可靠的定量指标;肝脏SUL因肝脏体积较大且SUL值均匀,为最佳内部参考。

研究设计与样本

  • 经HIPAA合规、IRB批准并豁免知情同意的回顾性影像回顾研究,纳入2018年9月至2019年5月间连续180例神经内分泌肿瘤患者,行68Ga-DOTATATE PET/CT(剂量0.054 mCi/Kg),测量肝脏和脾脏的SUVbw与SUL。

关键影像表现/征象

  • 测量肝脏和脾脏的体重归一化SUV(SUVbw)与瘦体重归一化SUV(SUL)。
  • 肝脏SUL方差最低(3.69%±1.25%)。

诊断标准与关键数值

  • 肝脏和脾脏SUL方差均显著低于SUVbw(P<0.0001)。
  • 肝脏SUVbw和SUL方差均显著低于脾脏对应SUV。
  • 肝脏SUL方差为3.69%±1.25%,在所有测量SUV中最低。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Standardized Uptake Value (SUV) is an important semiquantitative measurement used in the clinical and research domains to assess radiopharmaceutical concentration in tumors versus normal organs, but is susceptible to many factors beyond the tumor biological environment. So, the aim of this study is to identify the optimum internal reference among organs with physiological uptake in 68Ga-DOTATATE PET/CT (DOTA PET/CT) scans.

MATERIALS AND METHODS: This HIPAA-compliant, IRB-approved study with waiver of consent included retrospective imaging review of 180 consecutive patients with neuroendocrine tumors presenting for DOTA PET/CT image acquisition: Ga-68 DOTATATE dose was reported as (0.054 mCi/Kg) scans between September 2018 and May 2019. Mean value of body weight normalized SUV (SUVbw) and lean body mass normalized SUV (SUL) of liver and spleen were measured. Information about the patients and scan characteristics were collected. The paired Grambsch test was used to compare variance among the measured SUVs. Spearman's rank correlation coefficient was used to assess correlation between SUVs and potential patient- and scan-specific confounding factors.

RESULTS: Variance of SUL was significantly lower than variance of SUVbw in both liver and spleen (p-value < 0.0001). Variances of liver SUVbw and SUL were significantly lower than the corresponding spleen SUVs. Liver SUL showed the lowest variance (3.69% ± 1.25%) among all measured SUVs.

CONCLUSION: SUL is a more reproducible, less variable, and therefore more reliable quantitative measure in DOTA PET/CT scans, compared SUVbw. Among the available organs with physiological uptake, liver SUL is the optimum internal reference given the liver's larger size and uniform SUL values resulting in lower variability and better reproducibility.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Ragab A, Wu J, Ding X, et al. 68Ga-DOTATATE PET/CT: The Optimum Standardized Uptake Value (SUV) Internal Reference. Acad Radiol. 2020. PMID: 34756348. doi:10.1016/j.acra.2020.08.028

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。