对比增强3D MR血管成像与对比增强3D T1序列在感染性心内膜炎中检测颅内感染性动脉瘤的价值
以DSA为参考,评估对比增强MRA(CE MRA)与对比增强3D-T1对21例感染性心内膜炎患者30个颅内感染性动脉瘤的诊断价值;CE MRA敏感度80%、CE 3D-T1敏感度86.7%,两者特异度均为100%,准确度无显著差异;CE 3D-T1还可评估动脉瘤解剖关系,有助于DSA定位和血管内治疗。
要点
- CE MRA与CE 3D-T1检测颅内感染性动脉瘤特异度均为100%,准确度无显著差异。
- 两序列均能检出全部≥3 mm动脉瘤,也可检出≤3 mm者,但<2 mm者出现假阴性。
- CE 3D-T1可显示动脉瘤解剖关系,有助DSA定位和血管内治疗。
核心结论
- 与DSA相比,CE MRA和CE 3D-T1检测和描述颅内感染性动脉瘤均有良好准确度;CE 3D-T1还可评估动脉瘤解剖关系,可能有助于DSA定位和血管内治疗。
研究设计与样本
- 以DSA为参考标准,21例感染性心内膜炎患者(男14例,平均年龄53岁)共30个颅内感染性动脉瘤,直径1.5-15 mm(<3 mm者14个,占46.7%;3-5 mm者12个,占40%),在1.5 T行CE MRA和CE 3D-T1,两名阅片者评估动脉瘤检出、特征和可视化质量;DSA于MRI后中位3天(范围1-15天)获得。
关键影像表现/征象
- CE MRA检出颅内感染性动脉瘤的敏感度80%、特异度100%、阳性预测值100%、阴性预测值82.3%、准确度90%。
- CE 3D-T1检出颅内感染性动脉瘤的敏感度86.7%、特异度100%、阳性预测值100%、阴性预测值88.2%、准确度93.3%。
- CE MRA与CE 3D-T1在准确度和可视化质量方面无显著差异。
- 两序列均检出全部直径≥3 mm的动脉瘤(16/30,53%),也能检出直径≤3 mm的动脉瘤(14/30,46.7%)。
- 两序列对4个<2 mm动脉瘤出现假阴性,其中3个被出血性病灶压迫;CE MRA另漏诊2个<2 mm动脉瘤。
诊断标准与关键数值
- 以DSA为参考,CE MRA检测颅内感染性动脉瘤的敏感度80%、特异度100%、阳性预测值100%、阴性预测值82.3%、准确度90%。
- 以DSA为参考,CE 3D-T1检测颅内感染性动脉瘤的敏感度86.7%、特异度100%、阳性预测值100%、阴性预测值88.2%、准确度93.3%。
- CE 3D-T1相对DSA高估动脉瘤管腔直径8%(P = NS)。
- 两方法组内和组间一致性均良好且相似。
临床应用与阅片要点
- CE MRA与CE 3D-T1均可用于感染性心内膜炎患者颅内感染性动脉瘤的检出,两者准确度无显著差异。
- CE 3D-T1可评估动脉瘤解剖关系,作者认为可能有助于DSA定位和血管内治疗。
- 直径<2 mm的动脉瘤可被两序列漏诊,部分因被出血性病灶压迫。
局限性
- 两序列对4个<2 mm动脉瘤出现假阴性,其中3个被出血性病灶压迫。
- CE MRA另漏诊2个<2 mm动脉瘤。
- CE 3D-T1相对DSA高估动脉瘤管腔直径8%(P = NS)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To assess the diagnostic value of contrast-enhanced MRA (CE MRA) and CE 3D-T1 for identifying intracranial infectious aneurysms (IIAs) in infective endocarditis (IE) with digital substraction angiography (DSA) as reference.
METHODS: Twenty-one IE patients (14 males; mean age: 53 years) with 30 IIAs, diameter ranging 1.5-15 mm (<3mm, n = 14, 46.7%; 3-5 mm, n = 12,40%), underwent CE MRA and CE 3D-T1 at 1.5 T. Two readers evaluated images for aneurysm detection, characterization, quality of visualization. DSA was obtained at a median of 3 days (range 1-15) after MRI.
RESULTS: The sensitivity, specificity, positive and negative predictive values and accuracy of IIA detection were respectively: 80%, 100%, 100%, 82.3%, 90% for CE MRA and 86.7%, 100%, 100%, 88.2%, 93.3% for CE 3D T1 compared to DSA. No significant difference was observed between CE MRA and CE 3D-T1 for accuracy and quality of visualization. All IIAs of ≥3 mm in diameter (16/30; 53.%) were identified by both sequences, which were also able to detect IIAs ≤ 3 mm (n = 14/30, 46.7%). False negatives were observed with both sequences for 4 IIAs of <2 mm, 3 being compressed by hemorrhagic lesions. Two other IIAs of <2 mm were overlooked by CE MRA. CE 3D-T1 overestimated IIAs luminal diameter by 8% relatively to DSA (P = NS). Intra and inter-observer agreement were good and similar with both methods.
CONCLUSION: Both CE MRA and CE 3D-T1 have good accuracy compared to DSA detection and characterization of IIAs. CE 3D-T1 also evaluates anatomical relationships of IIAs, which could help DSA location and endovascular treatment.
引用
- Boukobza M, Ilic-Habensus E, Duval X, et al. Usefulness of contrast-enhanced 3D MR angiography and contrast-enhanced 3D T1 sequence for detecting intracranial infectious aneurysms in infectious endocarditis. Eur J Radiol. 2021. PMID: 34742109. doi:10.1016/j.ejrad.2021.110008
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。