文献速递神经MR

痉挛性截瘫5型的白质改变:一项多参数结构MRI研究及其与生化指标的相关性

White Matter Alterations in Spastic Paraplegia Type 5: A Multiparametric Structural MRI Study and Correlations with Biochemical Measurements.
PubMed 文献 · AJNR Am J Neuroradiol · 2021-11-18

研究纳入17例痉挛性截瘫5型患者和17名健康对照,在3T MR上行DTI和T1 mapping,并检测脑脊液神经丝轻链和髓鞘碱性蛋白。患者多个脊髓节段、放射冠、视辐射和内囊出现FA降低及MD、T1、RD升高,脑脊液神经丝轻链和髓鞘碱性蛋白高于对照,但临床数据与MRI指标无相关性。

要点

  • 痉挛性截瘫5型患者颈髓、T4/T5脊髓、放射冠、视辐射及内囊可见FA降低、MD与T1升高。
  • 脑脊液神经丝轻链和髓鞘碱性蛋白在患者中升高,提示髓鞘脱失为主伴轴索丢失。
  • 临床数据与MRI衍生指标之间未发现相关性。

核心结论

  • 多参数MRI和生化指标显示,痉挛性截瘫5型的白质完整性丧失由脱髓鞘(为主)和轴索丢失所致,而灰质未受累。

研究设计与样本

  • 研究纳入17例痉挛性截瘫5型患者和17名健康对照,在3T MR成像仪上行DTI和T1 mapping,采用Tract-Based Spatial Statistics和Spinal Cord Toolbox获取FA、MD、RD、AD和T1值,并检测脑脊液神经丝轻链和髓鞘碱性蛋白。

关键影像表现/征象

  • 大多数颈髓、T4和T5脊髓、放射冠、视辐射和内囊可见FA值广泛降低及MD、T1和RD值升高。
  • AD值变化仅见于C2、C6和放射冠,灰质未见变化。

诊断标准与关键数值

  • 痉挛性截瘫5型患者脑脊液髓鞘碱性蛋白为3507(SD,2291)pg/mL,健康对照为127(SD,219)pg/mL,P < .001。
  • 痉挛性截瘫5型患者脑脊液神经丝轻链为617(SD,207)pg/mL,健康对照为265(SD,187)pg/mL,P < .001。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: In spastic paraplegia type 5, spinal cord atrophy and white matter signal abnormalities in the brain are the main MR imaging alterations. However, the specific mechanism remains unclear. We explored the microstructural changes occurring in spastic paraplegia type 5 and assessed the relation between MR imaging and clinical data.

MATERIALS AND METHODS: Seventeen patients with spastic paraplegia type 5 and 17 healthy controls were scanned with DTI and T1 mapping on a 3T MR imaging scanner. Fractional anisotropy, mean diffusivity, radial diffusivity, axial diffusivity, and T1 values were obtained using Tract-Based Spatial Statistics and the Spinal Cord Toolbox. Neurofilament light and myelin basic protein in the CSF were measured. The differences in MR imaging and biochemical data between patients with spastic paraplegia type 5 and healthy controls were compared using the Student t test.

RESULTS: A widespread reduction of fractional anisotropy values and an elevation of mean diffusivity, T1, and radial diffusivity values were found in most cervical, T4, and T5 spinal cords; corona radiata; optic radiations; and internal capsules in spastic paraplegia type 5. A variation in axial diffusivity values was shown only in C2, C6, and the corona radiata but not in the gray matter. The levels of neurofilament light and myelin basic protein were higher in those with spastic paraplegia type 5 than in healthy controls (myelin basic protein, 3507 [SD, 2291] versus 127 [SD, 219] pg/mL; neurofilament light, 617 [SD, 207] versus 265 [SD, 187] pg/mL; P < .001). No correlation was found between the clinical data and MR imaging-derived measures.

CONCLUSIONS: Multiparametric MR imaging and biochemical indicators demonstrated that demyelination (mainly) and axonal loss led to the white matter integrity loss without gray matter injury in spastic paraplegia type 5.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Liu Y, Ye Z, Hu J, et al. White Matter Alterations in Spastic Paraplegia Type 5: A Multiparametric Structural MRI Study and Correlations with Biochemical Measurements. AJNR Am J Neuroradiol. 2021. PMID: 34794945. doi:10.3174/ajnr.A7344

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。