深度学习从T1加权同反相位MRI推断肝脏质子密度脂肪分数:基于人群试验数据的回顾性分析
本研究回顾性分析292名参与者,以化学位移编码MRI质子密度脂肪分数(CSE PDFF)为参考,比较深度学习卷积神经网络从常规T1加权同反相位图像推断的PDFF与两点Dixon信号脂肪分数的定量准确性。在74例测试集中,CNN推断PDFF与参考CSE PDFF的一致性(ICC=0.99)优于两点Dixon信号脂肪分数(ICC=0.93)。
要点
- CNN从常规T1加权同反相位图像推断的PDFF与CSE PDFF一致性高(ICC=0.99)。
- 两点Dixon信号脂肪分数与CSE PDFF一致性较低(ICC=0.93),偏差更大。
- CNN推断PDFF有望利用广泛可用的T1加权同反相位图像推广肝脏脂肪定量。
核心结论
- CNN从常规T1加权同反相位图像推断的PDFF与参考CSE PDFF的一致性优于两点Dixon信号脂肪分数。
研究设计与样本
- 回顾性分析Strong Heart Family Study中292名参与者(203名女性,89名男性;平均年龄53.7±12.0岁)的数据,两个中心分别使用3T和1.5T设备,采集T1加权同反相位MRI和CSE-MRI。随机抽取218名(75%)参与者训练CNN,其余74名(25%)用于测试。
诊断标准与关键数值
- 在74例测试集参与者中,参考CSE PDFF范围为1%至32%(均值11.3%±8.3%),参考CSE R2*范围为31至457秒⁻¹(均值62.4±67.3秒⁻¹)。CNN推断PDFF与参考CSE PDFF的ICC=0.99,偏差=-0.19%,95%一致性界限(-2.80%,2.71%);两点Dixon信号脂肪分数的ICC=0.93,偏差=-1.11%,95%一致性界限(-7.54%,5.33%)。
局限性
- 进一步研究需要在中度至重度铁过载个体中进行。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND. The confounder-corrected chemical shift-encoded MRI (CSE-MRI) sequence used to determine proton density fat fraction (PDFF) for hepatic fat quantification is not widely available. As an alternative, hepatic fat can be assessed by a two-point Dixon method to calculate signal fat fraction (FF) from conventional T1-weighted in- and opposed-phase (IOP) images, although signal FF is prone to biases, leading to inaccurate quantification. OBJECTIVE. The purpose of this study was to compare hepatic fat quantification by use of PDFF inferred from conventional T1-weighted IOP images and deep-learning convolutional neural networks (CNNs) with quantification by use of two-point Dixon signal FF with CSE-MRI PDFF as the reference standard. METHODS. This study entailed retrospective analysis of data from 292 participants (203 women, 89 men; mean age, 53.7 ± 12.0 [SD] years) enrolled at two sites from September 1, 2017, to December 18, 2019, in the Strong Heart Family Study (a prospective population-based study of American Indian communities). Participants underwent liver MRI (site A, 3 T; site B, 1.5 T) including T1-weighted IOP MRI and CSE-MRI (used to reconstruct CSE PDFF and CSE R2* maps). With CSE PDFF as reference, a CNN was trained in a random sample of 218 (75%) participants to infer voxel-by-voxel PDFF maps from T1-weighted IOP images; testing was performed in the other 74 (25%) participants. Parametric values from the entire liver were automatically extracted. Per-participant median CNN-inferred PDFF and median two-point Dixon signal FF were compared with reference median CSE-MRI PDFF by means of linear regression analysis, intraclass correlation coefficient (ICC), and Bland-Altman analysis. The code is publicly available at github.com/kang927/CNN-inference-of-PDFF-from-T1w-IOP-MR. RESULTS. In the 74 test-set participants, reference CSE PDFF ranged from 1% to 32% (mean, 11.3% ± 8.3% [SD]); reference CSE R2* ranged from 31 to 457 seconds-1 (mean, 62.4 ± 67.3 seconds-1 [SD]). Agreement metrics with reference to CSE PDFF for CNN-inferred PDFF were ICC = 0.99, bias = -0.19%, 95% limits of agreement (LoA) = (-2.80%, 2.71%) and for two-point Dixon signal FF were ICC = 0.93, bias = -1.11%, LoA = (-7.54%, 5.33%). CONCLUSION. Agreement with reference CSE PDFF was better for CNN-inferred PDFF from conventional T1-weighted IOP images than for two-point Dixon signal FF. Further investigation is needed in individuals with moderate-to-severe iron overload. CLINICAL IMPACT. Measurement of CNN-inferred PDFF from widely available T1-weighted IOP images may facilitate adoption of hepatic PDFF as a quantitative bio-marker for liver fat assessment, expanding opportunities to screen for hepatic steatosis and nonalcoholic fatty liver disease.
引用
- Wang K, Cunha GM, Hasenstab K, et al. Deep Learning for Inference of Hepatic Proton Density Fat Fraction From T1-Weighted In-Phase and Opposed-Phase MRI: Retrospective Analysis of Population-Based Trial Data. AJR Am J Roentgenol. 2023. PMID: 37466189. doi:10.2214/AJR.23.29607
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。