基于深度学习在头颈部CT血管造影上自动检测动脉狭窄的性能:一项独立外部验证研究
本研究以DSA为参考标准,在独立双中心数据集中外部验证CerebralDoc在头颈部CTA上自动检测动脉狭窄的性能。共分析296例患者,各层级和阈值下特异度均超过92%,AUC从0.615至0.945,敏感度从0.714至0.895。假阴性主要更常见于特定狭窄位置(尤其是M2段和颈内动脉颅底段)及闭塞。
要点
- CerebralDoc在头颈部CTA自动检测狭窄的各层级和阈值下特异度均超过92%。
- AUC从基于区域分析狭窄≥70%的0.615至基于患者分析狭窄≥50%的0.945。
- 敏感度从基于节段分析狭窄≥70%的0.714至基于患者分析狭窄≥50%的0.895。
核心结论
- CerebralDoc有潜力在头颈部CTA上自动检测狭窄,但需要进一步努力优化其性能。
研究设计与样本
- 回顾性纳入2019年1月至2021年12月期间接受头颈部CTA和DSA检查的患者,使用独立双中心数据集,以DSA为参考标准,共分析296例患者。
关键影像表现/征象
- 原文未报告影像征象。
诊断标准与关键数值
- 各层级和阈值下特异度均超过92%。
- AUC从基于区域分析狭窄≥70%的0.615(95% CI: 0.544, 0.686)至基于患者分析狭窄≥50%的0.945(95% CI: 0.905, 0.985)。
- 敏感度从基于节段分析狭窄≥70%的0.714(95% CI: 0.675, 0.750)至基于患者分析狭窄≥50%的0.895(95% CI: 0.849, 0.919)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To externally validate the performance of automated stenosis detection on head and neck CT angiography (CTA) and investigate the impact factors using an independent bi-center dataset with digital subtraction angiography (DSA) as the ground truth.
MATERIAL AND METHODS: Patients who underwent head and neck CTA and DSA between January 2019 and December 2021 were retrospectively included. The degree of stenosis was automatically evaluated using CerebralDoc based on CTA. The performance of CerebralDoc across levels (per-patient, per-region, per-vessel, and per-segment) and thresholds (≥ 50%, ≥ 70%, and = 100%) was evaluated. Logistic regression was performed to identify independent factors associated with false negative results.
RESULTS: 296 patients were analyzed. Specificity across levels and thresholds was high, exceeding 92%. The area under the curve ranged from poor (0.615, 95% CI: 0.544, 0.686; at the region-based analysis for stenosis ≥ 70%) to excellent (0.945, 95% CI: 0.905, 0.985; at the patient-based analysis for stenosis ≥ 50%). Sensitivity ranged from 0.714 (95% CI: 0.675, 0.750) at the segment-based analysis for stenosis ≥ 70% to 0.895 (95% CI: 0.849, 0.919) at the patient-based analysis for stenosis ≥ 50%. The multiple logistic regression analysis revealed that false negative results were primarily more likely to specific stenosis locations (particularly the M2 segment and skull base segment of the internal carotid artery) and occlusion.
CONCLUSIONS: CerebralDoc has the potential to automated stenosis detection on head and neck CTA, but further efforts are needed to optimize its performance.
引用
- Yang Y, Huan X, Guo D, et al. Performance of deep learning-based autodetection of arterial stenosis on head and neck CT angiography: an independent external validation study. Radiol Med. 2023. PMID: 37464200. doi:10.1007/s11547-023-01683-w
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。