文献速递骨肌CTMR

斜外侧腰椎椎间融合术后CT基于Hounsfield单位与MRI基于椎体骨质量评分对融合器下沉预测性能的比较

Comparison of predictive performance for cage subsidence between CT-based Hounsfield units and MRI-based vertebral bone quality score following oblique lumbar interbody fusion.
PubMed 文献 · Eur Radiol · 2023-07-18

本研究回顾性纳入2018至2020年在本机构接受斜外侧腰椎椎间融合联合前外侧单棒螺钉固定(OLIF-AF)的连续患者,比较术前CT基于Hounsfield单位(HU)与MRI基于椎体骨质量(VBQ)评分对融合器下沉(CS)的预测性能。结果显示CS组整体及节段VBQ评分均显著更高、HU值均显著更低,手术节段VBQ评分与HU值的AUC均高于整体腰椎测量,联合节段VBQ评分与节段HU值的AUC最高。作者结论认为两种测量均可准确预测CS,联合测量预测性能最佳。

要点

  • 手术节段VBQ评分与HU值预测CS的AUC高于整体腰椎测量
  • 联合节段VBQ评分与节段HU值对CS的预测性能最佳
  • CS组整体及节段VBQ评分显著更高、HU值显著更低

核心结论

  • MRI基于VBQ评分与CT基于HU值均可准确预测OLIF-AF术后融合器下沉,两者联合预测性能最佳。

研究设计与样本

  • 回顾性研究,纳入2018至2020年在本机构连续接受OLIF-AF的患者;CS由CT根据椎间隙中点高度变化判定,VBQ评分与HU值分别于术前MRI和CT测量,采用ROC曲线比较预测性能。

关键影像表现/征象

  • CS组整体与节段VBQ评分均显著高于非CS组
  • CS组整体与节段HU值均显著低于非CS组

诊断标准与关键数值

  • 手术节段VBQ评分与HU值预测CS的AUC均高于整体腰椎测量
  • 联合节段VBQ评分与节段HU值的AUC最高

临床应用与阅片要点

  • 作者指出MRI基于VBQ评分与CT基于HU值均可用于融合器下沉预测,以便尽早采取预防措施。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare the predictive performance between CT-based Hounsfield units (HU) and MRI-based vertebral bone quality (VBQ) for cage subsidence (CS) following oblique lumbar interbody fusion combined with anterolateral single-rod screw fixation (OLIF-AF).

METHODS: A retrospective study was performed on consecutive patients who underwent OLIF-AF at our institution from 2018 to 2020. CS was determined by CT according to the change in the midpoint intervertebral space height. The VBQ score and HU value were measured from preoperative MRI and CT, respectively. Then, we evaluated the predictive performance of those two parameters by comparing the receiver operating characteristic (ROC) curves.

RESULTS: The mean global and segmental VBQ scores were significantly higher in the CS group, and the mean global and segmental HU values were significantly lower in the CS group. The area under the curve (AUC) of CS prediction was higher in the operative segments' VBQ score and HU value than the measurement in the global lumbar spine. Finally, the combined segmental VBQ score and segmental HU value demonstrated the highest AUC.

CONCLUSION: Both MRI-based VBQ score and CT-based HU value can achieve accurate CS prediction. Moreover, the combination of those two measurements indicated the best predictive performance.

CLINICAL RELEVANCE STATEMENT: Both MRI-based VBQ score and CT-based HU value can be used for cage subsidence prediction, in order to take preventive measures early enough.

KEY POINTS: • Osteoporosis is a risk factor for CS, both MRI-based VBQ score and CT-based HU value are important predictors during vertebral bone quality evaluation. • The VBQ score and HU value measured in the operative segments are better predictors of CS than the measurement in the global lumbar spine. • Combined segmental VBQ score and segmental HU value achieved the best predictive performance for CS.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Pu X, Wang X, Ran L, et al. Comparison of predictive performance for cage subsidence between CT-based Hounsfield units and MRI-based vertebral bone quality score following oblique lumbar interbody fusion. Eur Radiol. 2023. PMID: 37462819. doi:10.1007/s00330-023-09929-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。