文献速递泌尿生殖腹部MR

前列腺癌局部分期中的MR图像质量:PI-QUAL在检测前列腺外侵犯中的作用

MR image quality in local staging of prostate cancer: Role of PI-QUAL in the detection of extraprostatic extension.
PubMed 文献 · Eur J Radiol · 2023-07-11

该回顾性研究纳入105例前列腺切除术前接受多参数前列腺MRI的患者,由两名放射科医师以共识方式用PI-QUAL评估图像质量(≥4分为高质量),并计算EPE Grade、Likert量表评分(LSS)和临床列线图(MSKCCn)对前列腺外侵犯(EPE)的预测准确性。总体66例扫描为高质量;放射学评分敏感度低(0.235-0.529)而特异度较高(0.775-0.986);图像质量欠佳时MSKCCn的AUC为0.76,优于EPE Grade(=3阈值)(0.821 vs 0.564,p=0.016)。结论认为用PI-QUAL评估图像质量有助于EPE评估,低质量扫描会使EPE Grade的表现较临床分期工具下降。

要点

  • PI-QUAL≥4分视为高质量,本组105例中66例扫描达高质量。
  • 放射学评分总体敏感度低(0.235-0.529),特异度较高(0.775-0.986),不受PI-QUAL评分影响。
  • 图像质量欠佳时MSKCCn的AUC为0.76,优于EPE Grade(=3阈值)(0.821 vs 0.564,p=0.016)。

核心结论

  • 用PI-QUAL评估图像质量有助于EPE评估,低质量扫描使EPE Grade的表现较临床分期工具下降。

研究设计与样本

  • 回顾性纳入105例前列腺切除术前接受多参数前列腺MRI的患者。
  • 两名放射科医师以共识方式用PI-QUAL评估图像质量,≥4分视为高质量。
  • 所有病例同时用EPE Grade、LSS和MSKCCn(二分类)评分,并评估各评分的评分者间可重复性。
  • 在全人群及按图像质量分层中计算准确性,EPE Grade采用≥2和=3两个阈值,LSS采用≥3和≥4两个阈值,并用McNemar检验比较。

诊断标准与关键数值

  • PI-QUAL≥4分视为高质量图像质量。
  • EPE Grade准确性范围为0.695-0.743,LSS准确性为0.705-0.733。
  • 放射学评分总体敏感度范围为0.235-0.529,特异度范围为0.775-0.986。
  • MSKCCn的AUC为0.76;图像质量欠佳研究中MSKCCn的AUC为0.821 vs EPE Grade(=3阈值)的0.564(p=0.016)。
  • EPE Grade(=3阈值)准确性在高质量研究中为0.849 vs 0.564(p=0.001)。

临床应用与阅片要点

  • 阅片时可先用PI-QUAL评估图像质量,高质量扫描(≥4分)时EPE Grade(=3阈值)准确性更好(0.849 vs 0.564,p=0.001)。
  • 图像质量欠佳时MSKCCn的AUC为0.76,优于EPE Grade(=3阈值)(0.821 vs 0.564,p=0.016),可提示结合临床列线图。
  • 放射学评分总体敏感度低(0.235-0.529)、特异度较高(0.775-0.986),判读EPE时需注意假阴性可能。
  • 各评分评分者间可重复性总体良好至优秀(95%CI范围0.782-0.924)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess the impact of prostate MRI image quality by means of the Prostate Imaging Quality (PI-QUAL) score, on the identification of extraprostatic extension of disease (EPE), predicted using the EPE Grade Score, Likert Scale Score (LSS) and a clinical nomogram (MSKCCn).

METHODS: We retrospectively included 105 patients with multiparametric prostate MRI prior to prostatectomy. Two radiologists evaluated image quality using PI-QUAL (≥4 was considered high quality) in consensus. All cases were also scored using the EPE Grade, the LSS, and the MSKCCn (dichotomized). Inter-rater reproducibility for each score was also assessed. Accuracy was calculated for the entire population and by image quality, considering two thresholds for EPE Grade (≥2 and = 3) and LSS (≥3 and ≥ 4) and using McNemar's test for comparison.

RESULTS: Overall, 66 scans achieved high quality. The accuracy of EPE Grade ranged from 0.695 to 0.743, while LSS achieved values between 0.705 and 0.733. Overall sensitivity for the radiological scores (range = 0.235-0.529) was low irrespective of the PI-QUAL score, while specificity was higher (0.775-0.986). The MSKCCn achieved an AUC of 0.76, outperforming EPE Grade (=3 threshold) in studies with suboptimal image quality (0.821 vs 0.564, p = 0.016). EPE Grade (=3 threshold) accuracy was also better in high image quality studies (0.849 vs 0.564, p = 0.001). Reproducibility was good to excellent overall (95 % Confidence Interval range = 0.782-0.924).

CONCLUSION: Assessing image quality by means of PI-QUAL is helpful in the evaluation of EPE, as a scan of low quality makes its performance drop compared to clinical staging tools.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Ponsiglione A, Stanzione A, Califano G, et al. MR image quality in local staging of prostate cancer: Role of PI-QUAL in the detection of extraprostatic extension. Eur J Radiol. 2023. PMID: 37453275. doi:10.1016/j.ejrad.2023.110973

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。