高分辨率磁共振血管壁成像鉴别动脉粥样硬化相关烟雾病血管病变与烟雾病的诊断效能
回顾性纳入265例成人患者(烟雾病160例、动脉粥样硬化相关烟雾病血管病变105例),评估大脑中动脉血管壁外径、重构指数和管壁增厚模式。动脉粥样硬化相关烟雾病血管病变组外径和重构指数更大、更常呈偏心性增厚(均P<0.001);外径鉴别两者的AUC为0.912、优于重构指数的0.889(P=0.007),截断值分别为1.77 mm和0.27。
要点
- 大脑中动脉外径鉴别动脉粥样硬化相关烟雾病血管病变与烟雾病的AUC为0.912,截断值1.77 mm。
- 重构指数AUC为0.889,截断值0.27;管壁增厚模式在非闭塞患者中AUC为0.786。
- 随管腔狭窄程度增加,外径、重构指数和管壁增厚模式的鉴别能力相应增强。
核心结论
- 高分辨率磁共振血管壁成像有助于鉴别烟雾病与动脉粥样硬化相关烟雾病血管病变,大脑中动脉外径的诊断效能优于重构指数和管壁增厚模式。
- 受累动脉外径在鉴别动脉粥样硬化相关烟雾病血管病变与烟雾病时准确且便捷,可能为临床诊断提供定量参考。
研究设计与样本
- 回顾性纳入诊断为烟雾病或动脉粥样硬化相关烟雾病血管病变并接受高分辨率磁共振血管壁成像的成人患者,共265例(烟雾病160例、动脉粥样硬化相关烟雾病血管病变105例)。
- 评估并比较大脑中动脉的三项血管壁特征(外径、重构指数、管壁增厚模式)鉴别烟雾病与动脉粥样硬化相关烟雾病血管病变的价值,并按管腔狭窄程度进行亚组分析、计算各特征的截断值。
关键影像表现/征象
- 动脉粥样硬化相关烟雾病血管病变患者较烟雾病患者大脑中动脉外径更大、重构指数更高,且更常表现为管壁偏心性增厚(均P<0.001)。
诊断标准与关键数值
- 外径鉴别烟雾病与动脉粥样硬化相关烟雾病血管病变的AUC为0.912,截断值1.77 mm。
- 重构指数鉴别烟雾病与动脉粥样硬化相关烟雾病血管病变的AUC为0.889,截断值0.27。
- 管壁增厚模式在非闭塞患者中鉴别烟雾病与动脉粥样硬化相关烟雾病血管病变的AUC为0.786。
- 外径AUC大于重构指数AUC(0.912 vs. 0.889,P=0.007)。
临床应用与阅片要点
- 阅片时可测量大脑中动脉外径(截断值1.77 mm)辅助鉴别动脉粥样硬化相关烟雾病血管病变与烟雾病。
- 结合重构指数(截断值0.27)和管壁增厚模式(非闭塞患者AUC 0.786)综合判断。
- 管腔狭窄程度增加时,三项血管壁特征的鉴别能力相应增强。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the diagnostic performance of high-resolution magnetic resonance-vessel wall imaging (HRMR-VWI) in differentiating moyamoya disease (MMD) from atherosclerosis-associated moyamoya vasculopathy (AS-MMV) and investigate an accurate approach for the differential diagnosis.
METHODS: Adult patients who were diagnosed as MMD or AS-MMV and underwent HRMR-VWI were retrospectively included. The three vessel wall features (outer diameter (OD), remodeling index (RI), and pattern of vessel wall thickening) of middle cerebral artery (MCA) in identifying MMD from AS-MMV were assessed and compared. Furthermore, subgroup analysis stratified by degree of luminal stenosis was performed and the cutoff values of different vessel wall features in differentiating MMD from AS-MMV were also calculated.
RESULTS: A total of 265 patients (160 cases of MMD and 105 AS-MMV) were included. Patients with AS-MMV had greater OD and RI and were more likely to exhibit eccentric thickening of vessel wall compared to those with MMD (all p < 0.001). The ROC analysis showed that the AUC value of OD was greater than that of RI (0.912 vs. 0.889, p = 0.007) in differentiating MMD from AS-MMV, and their corresponding cutoff values were 1.77 mm and 0.27, respectively. And the AUC value of pattern of vessel wall thickening was 0.786 in non-occluded patients. With the increase of lumen stenosis, the discrimination power of the three indicators enhanced correspondingly.
CONCLUSIONS: HRMR-VWI is valuable in distinguishing MMD from AS-MMV. The OD of MCA has better diagnostic performance in differentiating AS-MMV from MMD compared to RI and pattern of vessel wall thickening.
CLINICAL RELEVANCE STATEMENT: The outer diameter of the involved artery proved to be both accurate and convenient in distinguishing atherosclerosis-associated moyamoya vasculopathy from moyamoya disease and may provide a quantitative reference for clinical diagnosis.
KEY POINTS: High-resolution magnetic resonance-vessel wall imaging is valuable in distinguishing atherosclerosis-associated moyamoya vasculopathy from moyamoya disease. Compared to remodeling index and pattern of vessel wall thickening, outer diameter is more accurate in differentiating atherosclerosis-associated moyamoya vasculopathy from moyamoya disease. With the increase of lumen stenosis, the discrimination power of outer diameter, remodeling index, and pattern of vessel wall thickening enhanced correspondingly.
引用
- Liu S, Lu M, Gao X, et al. The diagnostic performance of high-resolution magnetic resonance-vessel wall imaging in differentiating atherosclerosis-associated moyamoya vasculopathy from moyamoya disease. Eur Radiol. 2023. PMID: 37453985. doi:10.1007/s00330-023-09951-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。