文献速递神经MR

非预载和高翻转角动态磁敏感对比灌注加权成像序列在脑淋巴瘤与胶质母细胞瘤术前鉴别中性能改善

Improved performance of non-preloaded and high flip-angle dynamic susceptibility contrast perfusion-weighted imaging sequences in the presurgical differentiation of brain lymphoma and glioblastoma.
PubMed 文献 · Eur Radiol · 2023-07-13

纳入336例患者(胶质母细胞瘤236例,原发性中枢神经系统淋巴瘤100例),比较预载与非预载对比剂的高翻转角DSC-PWI序列测量rCBV和PSR对两种肿瘤的术前鉴别准确性。结果显示非预载序列的PSR鉴别AUC高于预载序列(0.884 vs 0.529,p<0.001),rCBV的AUC两者无显著差异(0.949 vs 0.940,p=0.703);作者认为高翻转角非预载DSC-PWI序列可能为术前鉴别的首选序列。

要点

  • 非预载DSC-PWI的PSR鉴别胶质母细胞瘤与PCNSL的AUC为0.884,高于预载的0.529(p<0.001)。
  • rCBV鉴别AUC预载0.940 vs 非预载0.949,两者无显著差异(p=0.703)。
  • 高翻转角非预载DSC-PWI序列在术前鉴别中呈现最佳准确性,可能为首选序列。

核心结论

  • 预载对比剂时rCBV鉴别诊断性能未提高,PSR性能下降;高翻转角非预载DSC-PWI序列准确性优异,可能为术前鉴别脑淋巴瘤与胶质母细胞瘤的首选序列。

研究设计与样本

  • 连续纳入336例患者(胶质母细胞瘤236例,PCNSL 100例),术前在3.0-T磁共振设备上行DSC-PWI,测量预载与非预载对比剂的rCBV和PSR,连续变量均值用Welch t检验比较,各参数诊断准确性用受试者工作特征曲线分析比较。

关键影像表现/征象

  • 预载对比剂时rCBV高于非预载:胶质母细胞瘤10.20 vs 8.90(p=0.020),PCNSL 3.88 vs 3.27(p=0.020)。
  • 预载对比剂时PSR低于非预载:胶质母细胞瘤0.59 vs 0.90,PCNSL 0.70 vs 1.63(均p<0.001)。

诊断标准与关键数值

  • 鉴别胶质母细胞瘤与PCNSL,预载rCBV的AUC为0.940,非预载rCBV的AUC为0.949,两者无显著差异(p=0.703)。
  • 鉴别胶质母细胞瘤与PCNSL,预载PSR的AUC为0.529,低于非预载PSR的AUC 0.884(p<0.001)。

临床应用与阅片要点

  • 高翻转角非预载DSC-PWI序列可能为术前鉴别脑淋巴瘤与胶质母细胞瘤的首选序列(作者结论)。
  • 为非最准确CBV计算而优化的DSC-PWI序列可能不是术前脑肿瘤诊断的最佳序列,因其可能掩盖泄漏现象,而泄漏现象可提供有价值的鉴别诊断信息。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This study aimed to compare the accuracy of relative cerebral blood volume (rCBV) and percentage signal recovery (PSR) obtained from high flip-angle dynamic susceptibility contrast perfusion-weighted imaging (DSC-PWI) sequences with and without contrast agent (CA) preload for presurgical discrimination of brain glioblastoma and lymphoma.

METHODS: Consecutive 336 patients (glioblastoma, 236; PCNSL, 100) were included. All the patients underwent DSC-PWI on 3.0-T magnetic resonance units before surgery. The rCBV and PSR with preloaded and non-preloaded CA were measured. The means of the continuous variables were compared using Welch's t-test. The diagnostic accuracies of the individual parameters were compared using the receiver operating characteristic curve analysis.

RESULTS: The rCBV was higher with preloaded CA than with non-preloaded CA (glioblastoma, 10.20 vs. 8.90, p = 0.020; PCNSL, 3.88 vs. 3.27, p = 0.020). The PSR was lower with preloaded CA than with non-preloaded CA (glioblastoma, 0.59 vs. 0.90; PCNSL, 0.70 vs. 1.63; all p < 0.001). Regarding the differentiation of glioblastoma and PCNSL, the AUC of rCBV with preloaded CA was indistinguishable from that of non-preloaded CA (0.940 vs. 0.949, p = 0.703), whereas the area under the curve of PSR with preloaded CA was lower than non-preloaded CA (0.529 vs. 0.884, p < 0.001).

CONCLUSION: With preloaded CA, diagnostic performance in differentiating glioblastoma and PCNSL did not improve for rCBV and it was decreased for PSR. Therefore, high flip-angle non-preload DSC-PWI sequences offer excellent accuracy and may be of choice sequence for presurgical discrimination of brain lymphoma and glioblastoma.

CLINICAL RELEVANCE STATEMENT: High flip-angle DSC-PWI using non-preloaded CA may be an excellent diagnostic method for distinguishing glioblastoma from PCNSL.

KEY POINTS: • Differentiating primary central nervous system lymphoma and glioblastoma accurately is critical for their management. • DSC-PWI sequences optimised for the most accurate CBV calculations may not be the optimal sequences for presurgical brain tumour diagnosis as they could be masquerading leakage phenomena that may provide interesting information in terms of differential diagnosis. • High flip-angle non-preloaded DSC-PWI sequences render the best accuracy in the presurgical differentiation of brain lymphoma and glioblastoma.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Wang F, Zhou X, Chen R, et al. Improved performance of non-preloaded and high flip-angle dynamic susceptibility contrast perfusion-weighted imaging sequences in the presurgical differentiation of brain lymphoma and glioblastoma. Eur Radiol. 2023. PMID: 37439934. doi:10.1007/s00330-023-09917-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。