指南与共识腹部泌尿生殖技术与安全MR

代表Elekta MRI-linac联盟图像分析工作组提出的改善ADC推导可重复性的建议

Recommendations for improved reproducibility of ADC derivation on behalf of the Elekta MRI-linac consortium image analysis working group
RSS 订阅 · 指南共识 · 腹部影像 · 2023-07-12

该研究让9个中心对肾上腺、盆腔寡转移、胰腺和前列腺肿瘤的扩散加权与解剖磁共振图像勾画GTV、CTV和VTV并计算ADC,评估勾画与计算相关的ADC变异。结果显示计算方法对ADC可重复性的影响大于勾画,b值组间ADC差异18%、ROI与体素法差异4%,均值与中位数无显著差异,统一计算条件后计算变异降低。

要点

  • 计算方法对ADC可重复性的影响大于勾画,计算变异中位数0.17,勾画变异中位数0.06。
  • b值0-500与150-500 s/mm²组间ADC估计差异18%,ROI与体素法差异4%,均P<0.01。
  • 均值与中位数ADC无显著差异(P=0.64),统一计算条件后计算变异降至0.04。

核心结论

  • 计算方法对ADC可重复性的影响大于勾画,识别出的显著变异来源应在启动新研究尤其是多中心研究时予以考虑。

研究设计与样本

  • 9个中心使用相同的肾上腺、盆腔寡转移、胰腺和前列腺肿瘤扩散加权与解剖磁共振图像,勾画GTV、CTV和VTV,并分别用本中心计算方法和统一计算条件计算ADC。

诊断标准与关键数值

  • 勾画变异中位数(范围)CV_D为0.06(0.02-0.32),计算变异中位数(范围)CV_C为0.17(0.08-0.26);b值0-500 vs 150-500 s/mm²组间ADC估计差异18%(P<0.01);ROI法 vs 体素法差异4%(P<0.01);均值 vs 中位数无显著差异(P=0.64);统一计算条件后CV_C降至0.04(0.01-0.16)。

临床应用与阅片要点

  • 基于观察与讨论,Elekta MRI-linac联盟图像分析工作组提出ADC计算建议,启动新研究尤其是多中心研究时应考虑已识别的显著变异来源。

局限性

  • 原文未报告局限性。
英文原文(摘要)· 点击展开

Radiother Oncol. 2023 Sep;186:109803. doi: 10.1016/j.radonc.2023.109803. Epub 2023 Jul 10. ABSTRACT BACKGROUND AND PURPOSE: The apparent diffusion coefficient (ADC), a potential imaging biomarker for radiotherapy response, needs to be reproducible before translation into clinical use. The aim of this study was to evaluate the multi-centre delineation- and calculation-related ADC variation and give recommendations to minimize it. MATERIALS AND METHODS: Nine centres received identical diffusion-weighted and anatomical magnetic resonance images of different cancerous tumours (adrenal gland, pelvic oligo metastasis, pancreas, and prostate). All centres delineated the gross tumour volume (GTV), clinical target volume (CTV), and viable tumour volume (VTV), and calculated ADCs using both their local calculation methods and each of the following calculation conditions: b-values 0-500 vs. 150-500 s/mm 2 , region-of-interest (ROI)-based vs. voxel-based calculation, and mean vs. median. ADC variation was assessed using the mean coefficient of variation across delineations (CV D ) and calculation methods (CV C ). Absolute ADC differences between calculation conditions were evaluated using Friedman's test. Recommendations for ADC calculation were formulated based on observations and discussions within the Elekta MRI-linac consortium image analysis working group. RESULTS: The median (range) CV D and CV C were 0.06 (0.02-0.32) and 0.17 (0.08-0.26), respectively. The ADC estimates differed 18% between b-value sets and 4% between ROI/voxel-based calculation (p-values < 0.01). No significant difference was observed between mean and median (p = 0.64). Aligning calculation conditions between centres reduced CV C to 0.04 (0.01-0.16). CV D was comparable between ROI types. CONCLUSION: Overall, calculation methods had a larger impact on ADC reproducibility compared to delineation. Based on the results, significant sources of variation were identified, which should be considered when initiating new studies, in particular multi-centre investigations. PMID: 37437609 | PMC: PMC11197850 | DOI: 10.1016/j.radonc.2023.109803

来源:指南共识 · 腹部影像,查看原文。版权归原作者所有。

引用

  1. 指南共识 · 腹部影像:Recommendations for improved reproducibility of ADC derivation on behalf of the Elekta MRI-linac consortium image analysis working group

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。