磁场强度对胎儿脑生物测量的影响:一项单中心回顾性MRI队列研究

Effect of magnet strength on fetal brain biometry - a single-center retrospective MRI-based cohort study.
PubMed 文献 · Neuroradiology · 2023-07-12

该单中心回顾性队列纳入2012至2021年间1150例脑解剖表现正常的低风险胎儿,比较1.5 T(442例)与3.0 T(708例)扫描的手动胎儿脑生物测量百分位。双顶径、小脑横径及胼胝体长度在两种场强间无显著差异;小脑蚓部高度(3.0 T 54.6百分位 vs 1.5 T 39.0百分位,p<0.001)、小脑蚓部宽度(46.9 vs 37.5百分位,p=0.03)在3.0 T更高,额枕径在1.5 T更高(66.0 vs 61.8百分位,p=0.02)。作者指出3.0 T应用增多可能对基于1.5 T的参考图表带来潜在偏倚。

要点

  • 双顶径、小脑横径、胼胝体长度的百分位在1.5 T与3.0 T间无显著差异。
  • 小脑蚓部高度百分位3.0 T高于1.5 T(54.6 vs 39.0,p<0.001)。
  • 额枕径百分位1.5 T高于3.0 T(66.0 vs 61.8,p=0.02)。

核心结论

  • 使用手动生物测量时,1.5 T与3.0 T胎脑测量总体可比,场强间差异较小;但评估小脑蚓部等小结构时差异可能较大,3.0 T应用增多对基于1.5 T的参考图表构成潜在偏倚。

研究设计与样本

  • 单中心回顾性队列研究,纳入2012至2021年间1150例脑解剖表现正常的低风险胎儿,其中1.5 T扫描442例、3.0 T扫描708例,两群体特征可比,均在同一三级医疗中心完成。

关键影像表现/征象

  • 手动测量双顶径、额枕径、小脑横径、胼胝体长度、小脑蚓部高度及宽度,并转换为基于既往报道的生物测量参考图表的百分位。
  • 小脑蚓部高度百分位3.0 T为54.6、1.5 T为39.0(p<0.001),3.0 T更高。
  • 小脑蚓部宽度百分位3.0 T为46.9、1.5 T为37.5(p=0.03)。
  • 额枕径百分位1.5 T为66.0、3.0 T为61.8(p=0.02),1.5 T更高。

诊断标准与关键数值

  • 双顶径、小脑横径、胼胝体长度的百分位在1.5 T与3.0 T间无显著差异。
  • 小脑蚓部高度百分位:3.0 T 54.6 vs 1.5 T 39.0,p<0.001。
  • 小脑蚓部宽度百分位:3.0 T 46.9 vs 1.5 T 37.5,p=0.03。
  • 额枕径百分位:1.5 T 66.0 vs 3.0 T 61.8,p=0.02。

临床应用与阅片要点

  • 作者指出,使用基于1.5 T的参考图表评估3.0 T胎儿影像时存在潜在偏倚。
  • 作者认为场强间小差异可能与3.0 T更高空间分辨率有关,评估小脑蚓部等小脑结构时差异可能较大。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Abnormal fetal brain measurements might affect clinical management and parental counseling. The effect of between-field-strength differences was not evaluated in quantitative fetal brain imaging until now. Our study aimed to compare fetal brain biometry measurements in 3.0 T with 1.5 T scanners.

METHODS: A retrospective cohort of 1150 low-risk fetuses scanned between 2012 and 2021, with apparently normal brain anatomy, were retrospectively evaluated for biometric measurements. The cohort included 1.5 T (442 fetuses) and 3.0 T scans (708 fetuses) of populations with comparable characteristics in the same tertiary medical center. Manually measured biometry included bi-parietal, fronto-occipital and trans-cerebellar diameters, length of the corpus-callosum, vermis height, and width. Measurements were then converted to centiles based on previously reported biometric reference charts. The 1.5 T centiles were compared with the 3.0 T centiles.

RESULTS: No significant differences between centiles of bi-parietal diameter, trans-cerebellar diameter, or length of the corpus callosum between 1.5 T and 3.0 T scanners were found. Small absolute differences were found in the vermis height, with higher centiles in the 3.0 T, compared to the 1.5 T scanner (54.6th-centile, vs. 39.0th-centile, p < 0.001); less significant differences were found in vermis width centiles (46.9th-centile vs. 37.5th-centile, p = 0.03). Fronto-occipital diameter was higher in 1.5 T than in the 3.0 T scanner (66.0th-centile vs. 61.8th-centile, p = 0.02).

CONCLUSIONS: The increasing use of 3.0 T MRI for fetal imaging poses a potential bias when using 1.5 T-based charts. We elucidate those biometric measurements are comparable, with relatively small between-field-strength differences, when using manual biometric measurements. Small inter-magnet differences can be related to higher spatial resolution with 3 T scanners and may be substantial when evaluating small brain structures, such as the vermis.