文献速递骨肌技术与安全PETCT

评估SUV指数(一种源自FDG PET/CT的指标)诊断风湿性多肌痛的可行性

Assessing the feasibility of SUVindex (a metric derived from FDG PET/CT) for the diagnosis of polymyalgia rheumatica.
PubMed 文献 · Clin Radiol · 2023-06-28

本研究回顾性纳入风湿性多肌痛(PMR)患者及症状相似但诊断为其他疾病的对照,对18个部位的18F-FDG摄取进行半定量与定性分析,用逻辑回归和广义相加模型评估PET/CT的诊断价值。特征部位SUV指数的AUC为0.930,最佳截断值1.685,敏感度84.6%、特异度92.6%;该指数≥2.56时PMR诊断概率逐渐达到阈值效应,高达90%以上。作者结论认为特征部位SUV指数是诊断PMR的独立因素,≥1.685时应高度怀疑PMR,但该发现基于初步回顾性单中心研究,需外部验证和进一步前瞻性评估后才能转化为临床实践。

要点

  • PMR特征部位为坐骨结节、棘间滑囊、髋关节周围及耻骨联合附着点。
  • 特征部位SUV指数诊断PMR的AUC为0.930,最佳截断值1.685。
  • 截断值1.685时敏感度84.6%、特异度92.6%;指数≥2.56时诊断概率达90%以上。

核心结论

  • 特征部位SUV指数是诊断PMR的独立因素,当其≥1.685时应高度怀疑PMR。
  • 作者指出该发现基于初步回顾性单中心研究,需外部验证和进一步前瞻性评估后才能转化为临床实践。

研究设计与样本

  • 研究类型为回顾性研究,纳入PMR患者及症状相似但诊断为其他疾病的对照。
  • 对所有患者18个部位的18F-FDG摄取进行半定量与定性分析。
  • 由两名工作经验丰富的核医学医师独立阅片。
  • 使用R软件通过逻辑回归和广义相加模型评估PET/CT对PMR的诊断价值。

关键影像表现/征象

  • PMR的特征部位为坐骨结节、棘间滑囊、髋关节周围及耻骨联合附着点。

诊断标准与关键数值

  • 特征部位SUV指数诊断PMR的AUC为0.930,最佳截断值1.685,敏感度84.6%、特异度92.6%。
  • 调整潜在混杂因素后,PMR诊断概率随特征部位SUV指数升高而增加,两者呈非线性相关。
  • 特征部位SUV指数≥2.56时,PMR诊断概率逐渐达到阈值效应,高达90%以上。

临床应用与阅片要点

  • 作者结论认为特征部位SUV指数≥1.685时应高度怀疑PMR。
  • 作者指出该发现需外部验证和进一步前瞻性评估后才能转化为临床实践。

局限性

  • 原文指出该研究为初步的回顾性单中心研究。
  • 原文指出该发现需要外部验证和进一步前瞻性评估后才能转化为临床实践。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To evaluate the feasibility of standard uptake value (SUV) index (ratio lesional maximum SUV [SUVmax] to liver mean SUV [SUVmean]) as a metabolic parameter for diagnosing polymyalgia rheumatica (PMR).

MATERIALS AND METHODS: A retrospective group of patients with PMR and controls with symptoms similar to PMR but diagnosed with other diseases. Semiquantitative and qualitative analysis of 2-[18F]-fluoro-2-deoxy-d-glucose (18F-FDG) uptake at 18 sites was undertaken for all patients. The diagnostic value of positron-emission tomography/computed tomography (PET/CT) for PMR was assessed by R software using logistic regression and a generalised additive model (GAM). All images were examined independently by two nuclear medicine physicians with extensive work experience.

RESULTS: The characteristic sites of PMR were the ischial tuberosity, interspinous bursa, periarticular hip, and symphysis pubis enthesis. The area under the curve (AUC) of the characteristic site SUV index was 0.930, and the best cut-off value was 1.685 with a sensitivity of 84.6% and a specificity of 92.6%. After adjusting for potential confounders, the probability of PMR diagnosis increased as the characteristic site SUV index increased and there was a nonlinear correlation between the two. When the characteristic site SUV index was ≥2.56, the probability of PMR gradually reached the threshold effect, which was as high as 90% or more.

CONCLUSION: The characteristic site SUV index is an independent factor for diagnosing PMR, and PMR should be highly suspected when it is ≥ 1.685. Nonetheless, it is important to note that these findings are based on an initial retrospective single-centre study and require external validation and further prospective evaluation before being translated into clinical practice.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Sun S, Shao X, Liu X, et al. Assessing the feasibility of SUVindex (a metric derived from FDG PET/CT) for the diagnosis of polymyalgia rheumatica. Clin Radiol. 2023. PMID: 37429761. doi:10.1016/j.crad.2023.06.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。