文献速递甲状腺与浅表US

基于多模态超声的预测模型用于≤10mm甲状腺结节的鉴别诊断

The predictive models based on multimodality ultrasonography for the differential diagnosis of thyroid nodules smaller than 10 mm.
PubMed 文献 · Br J Radiol · 2023-07-05

该回顾性研究纳入198例甲状腺手术患者的198个≤10mm结节,以病理为金标准,基于常规超声、剪切波弹性成像、应变弹性成像和超声造影构建多模态超声预测模型。模型一(ACR TI-RADS评分联合PNSR和SWE比值)敏感度最高(92.8%),模型三(TI-RADS评分联合PNSR、SWE比值及特定CEUS指标)特异度、准确率和AUC最高(分别为90.2%、91.4%和0.958)。研究表明多模态超声预测模型可有效提高≤10mm甲状腺结节的鉴别诊断效能。

要点

  • ≤10mm甲状腺结节鉴别中,弹性成像和CEUS可作为ACR TI-RADS的有效补充。
  • 模型一联合ACR TI-RADS评分、PNSR和SWE比值,敏感度达92.8%。
  • 模型三联合TI-RADS评分、PNSR、SWE比值及CEUS特征,AUC达0.958。

核心结论

  • 多模态超声预测模型有效提高了≤10mm甲状腺结节的鉴别诊断效能。

研究设计与样本

  • 回顾性研究,纳入198例甲状腺手术患者的198个最大直径≤10mm结节,其中良性72个、恶性126个。
  • 术前均行常规超声、剪切波弹性成像、应变弹性成像和超声造影检查,以术后病理为金标准。
  • 基于超声图像表现通过逻辑回归分析构建多模态超声预测模型,并采用五折交叉验证进行内部验证。

关键影像表现/征象

  • 超声造影特定特征包括增强边界、增强方向和结节面积减小。
  • 应变弹性成像的实质-结节应变比(PNSR)和剪切波弹性成像比值(SWE ratio)被纳入预测模型。

诊断标准与关键数值

  • 模型一(ACR TI-RADS评分联合PNSR和SWE比值)敏感度最高,为92.8%。
  • 模型三(TI-RADS评分联合PNSR、SWE比值及特定CEUS指标)特异度90.2%、准确率91.4%、AUC 0.958,均为最高。

临床应用与阅片要点

  • 对于≤10mm甲状腺结节,在ACR TI-RADS评分基础上联合弹性成像参数和CEUS特征可提高诊断信心。
  • 阅片时需关注CEUS的增强边界、增强方向及结节面积减小等特征,并结合PNSR和SWE比值综合评估。

局限性

  • 回顾性研究设计。
  • 仅进行内部五折交叉验证,缺乏外部验证。
  • 样本来自单中心手术患者,存在选择偏倚可能。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The objective of this study was to establish a multimodality ultrasound prediction model based on conventional ultrasound (Con-US), shear wave elastography (SWE), and strain elastography (SE) and contrast-enhanced ultrasound (CEUS) and to explore their diagnostic values for thyroid nodules ≤ 10 mm.

METHODS: This retrospective study included 198 thyroid nodules (maximum diameter≤10 mm) in 198 thyroid surgery patients who were examined preoperatively with above-mentioned methods. The pathological findings of the thyroid nodules were used as the gold standard, and there were 72 benign nodules and 126 malignant nodules. The multimodal ultrasound prediction models were developed by logistic regression analysis based on the ultrasound image appearances. The diagnostic efficacy of these prediction models was then compared and internally cross-validated in a fivefold manner.

RESULTS: The specific features on CEUS (enhancement boundary, enhancement direction and decreased nodule area) and the parenchyma-to-nodule strain ratio (PNSR) on SE and SWE ratio were included in the prediction model. The Model one combining American College of Radiology Thyroid Imaging Reporting and Data Systems (ACR TI-RADS) score with PNSR and SWE ratio had the highest sensitivity (92.8%), while the Model three combining TI-RADS score with PNSR, SWE ratio and specific CEUS indicators had the highest specificity, accuracy, and AUC (90.2%,91.4%, and 0.958, respectively).

CONCLUSION: The multimodality ultrasound predictive models effectively improved the differential diagnosis of thyroid nodules smaller than 10 mm.

ADVANCES IN KNOWLEDGE: For the differential diagnosis of thyroid nodules ≤ 10 mm, both ultrasound elastography and CEUS could be effective complements to ACR TI-RADS.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Li G, Ma S, Zhang F, et al. The predictive models based on multimodality ultrasonography for the differential diagnosis of thyroid nodules smaller than 10 mm. Br J Radiol. 2023. PMID: 37427752. doi:10.1259/bjr.20221120

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。