深度学习生成的合成STIR脊柱MR图像质量优于常规STIR且诊断等效:一项多中心多阅片者试验
该多中心多阅片者研究从328例临床病例中随机选取93例患者的110个脊柱MR检查,用深度学习应用基于矢状位T1和T2生成合成STIR序列。五位放射科医师盲法随机评估合成STIR与采集STIR,结果显示两者诊断可互换(非劣效阈值10%),且合成STIR图像质量评分显著更高(P < .0001)。
要点
- 合成STIR与采集STIR诊断可互换,阅片者间一致性变化在非劣效阈值内。
- 合成STIR图像质量评分显著高于采集STIR(P < .0001)。
- 合成STIR可由常规T1和T2生成,有望用于常规临床实践。
局限性
- 样本量有限(93例患者,110个检查)。
- 仅评估矢状位脊柱STIR,未涉及其他序列或部位。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Deep learning image reconstruction allows faster MR imaging acquisitions while matching or exceeding the standard of care and can create synthetic images from existing data sets. This multicenter, multireader spine study evaluated the performance of synthetically created STIR compared with acquired STIR.
MATERIALS AND METHODS: From a multicenter, multiscanner data base of 328 clinical cases, a nonreader neuroradiologist randomly selected 110 spine MR imaging studies in 93 patients (sagittal T1, T2, and STIR) and classified them into 5 categories of disease and healthy. A DICOM-based deep learning application generated a synthetically created STIR series from the sagittal T1 and T2 images. Five radiologists (3 neuroradiologists, 1 musculoskeletal radiologist, and 1 general radiologist) rated the STIR quality and classified disease pathology (study 1, n = 80). They then assessed the presence or absence of findings typically evaluated with STIR in patients with trauma (study 2, n = 30). The readers evaluated studies with either acquired STIR or synthetically created STIR in a blinded and randomized fashion with a 1-month washout period. The interchangeability of acquired STIR and synthetically created STIR was assessed using a noninferiority threshold of 10%.
RESULTS: For classification, there was a decrease in interreader agreement expected by randomly introducing synthetically created STIR of 3.23%. For trauma, there was an overall increase in interreader agreement by +1.9%. The lower bound of confidence for both exceeded the noninferiority threshold, indicating interchangeability of synthetically created STIR with acquired STIR. Both the Wilcoxon signed-rank and t tests showed higher image-quality scores for synthetically created STIR over acquired STIR (P < .0001).
CONCLUSIONS: Synthetically created STIR spine MR images were diagnostically interchangeable with acquired STIR, while providing significantly higher image quality, suggesting routine clinical practice potential.
引用
- Tanenbaum, Bash, Zaharchuk, et al. Deep Learning-Generated Synthetic MR Imaging STIR Spine Images Are Superior in Image Quality and Diagnostically Equivalent to Conventional STIR: A Multicenter, Multireader Trial. AJNR Am J Neuroradiol. 2023. PMID: 37414452. doi:10.3174/ajnr.A7920
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。