文献速递神经外周血管CTCTA

Willis环完整性对初诊慢性颈内动脉闭塞无症状或轻症患者的影响

Influence of the integrity of circle of Willis on asymptomatic or mild patients with first diagnosed chronic internal carotid artery occlusion.
PubMed 文献 · Eur J Radiol · 2023-06-30

该回顾性研究纳入38例未接受再灌注治疗的初诊慢性颈内动脉闭塞无症状或轻症患者,基于CTA评估Willis环完整性并分为良好组与不良组。所有患者患侧供血区均见TTP延长,两组TTP延长体积和数值差异有统计学意义(P < 0.001)。Willis环状态是新发脑梗死和TTP延长体积增大的独立预测因素。

要点

  • 初诊慢性颈内动脉闭塞无症状或轻症患者中,患侧供血区均可见TTP延长。
  • Willis环完整性不良组TTP延长体积和数值均高于良好组(P < 0.001)。
  • Willis环状态是新发脑梗死和TTP延长体积增大的独立预测因素。

核心结论

  • 评估Willis环完整性对于评价未接受再灌注治疗的初诊慢性颈内动脉闭塞无症状或轻症患者的异常灌注至关重要。

研究设计与样本

  • 回顾性研究,纳入38例未接受再灌注治疗的初诊慢性颈内动脉闭塞无症状或轻症患者,基于CTA评估Willis环完整性并分为良好组与不良组,评估两组TTP延长体积和数值及新发脑梗死,采用多因素回归和ROC分析。

关键影像表现/征象

  • 全部38例患者患侧供血区均观察到以TTP延长为特征的血流动力学异常。
  • 良好组与不良组之间TTP延长的体积和数值差异有统计学意义(P < 0.001)。
  • 基于CTP和CTA参数的相关分析显示,Willis环评分与TTP异常体积(r = -0.624,P = 0.000)及异常数值(r = -0.589,P = 0.000)均呈负相关。

诊断标准与关键数值

  • 基于CTA评估Willis环完整性,将患者分为良好完整性和不良完整性两组。
  • 多因素调整后,新发脑梗死的独立预测因素仅为Willis环状态(b = 6.05;95%CI:1.619,22.619;P = 0.007)。
  • 多因素调整后,TTP延长体积增大的独立预测因素仅为Willis环状态(b = 35.486;95%CI:4.697,268.088;P = 0.001)。

临床应用与阅片要点

  • 对初诊慢性颈内动脉闭塞无症状或轻症患者,可结合CTA评估Willis环完整性以辅助判断灌注异常程度。
  • 患侧供血区TTP延长是常见灌注异常表现,Willis环完整性不良者TTP延长体积和数值更高。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: In order to identify individuals with chronic internal carotid artery occlusion (CICAO), it is essential to understand the integrity of the circle of Willis (CoW). This understanding is important as it may determine the potential benefits of active medical and endovascular treatments.

PURPOSE: The objective of this study is to assess whether diminished integrity of the CoW can serve as a useful marker for identifying individuals with more severe impairment in cerebral blood perfusion and a higher incidence of cerebral infarction among asymptomatic or mildly affected patients with CICAO.

MATERIALS AND METHODS: We conducted a retrospective review of asymptomatic or mildly affected patients with newly diagnosed CICAO who did not receive reperfusion therapies. The categorization of patients into good or poor integrity groups was based on the assessment of CoW integrity using CTA. We evaluated the volume and value of prolonged time to peak (TTP) in both groups, as well as the occurrence of new cerebral infarctions. Our analysis involved multivariate regression and receiver operating characteristic (ROC) analysis.

RESULTS: Hemodynamic abnormalities characterized by prolonged TTP were observed in the affected side's blood supply region in all 38 patients. There was a notable difference in the volume and value of prolonged TTP between the two groups (P < 0.001). Correlation analyses based on CTP and CTA parameters revealed a negative relationship between CoW scores and both the abnormal volume (r = -0.624, P = 0.000) and value (r = -0.589, P = 0.000) of prolonged TTP. Upon multivariable adjustment, the independent predictors for new cerebral infarction and higher volume of prolonged TTP were solely the CoW status, with respective estimates of (b = 6.05; 95% confidence interval [CI]: 1.619, 22.619; P = 0.007) and (b = 35.486; 95% CI: 4.697, 268.088; P = 0.001).

CONCLUSION: Assessing the integrity of the CoW is crucial in evaluating abnormal perfusion in asymptomatic or mildly affected individuals who are newly diagnosed with CICAO and have not undergone reperfusion therapy.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Zhang, Wang, Gao, et al. Influence of the integrity of circle of Willis on asymptomatic or mild patients with first diagnosed chronic internal carotid artery occlusion. Eur J Radiol. 2023. PMID: 37406584. doi:10.1016/j.ejrad.2023.110954

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。