透视与仅摄片检查评估胃造瘘管和胃空肠造瘘管的回顾性队列比较
该单中心回顾性队列研究纳入2008年1月1日至2019年1月1日间212例胃造瘘管或胃空肠造瘘管检查,比较透视与仅摄片两种方式对管异位及其他影像可检出不良事件的敏感度和特异度。结果显示两种方法对管异位的敏感度和特异度相似,透视对管异位敏感度100%、特异度100%,仅摄片敏感度75%、特异度100%。
要点
- 仅摄片检查对胃造瘘管或胃空肠造瘘管异位的敏感度为75%,特异度为100%。
- 透视检查对管异位的敏感度为100%,特异度为100%。
- 最常被漏诊的不良事件为管周渗漏,共8例假阴性。
核心结论
- 透视与仅摄片检查对检测胃造瘘管或胃空肠造瘘管异位具有相似的敏感度和特异度。
研究设计与样本
- 单中心三级儿科中心回顾性队列研究,纳入2008年1月1日至2019年1月1日间接受透视或仅摄片管检查的212例次检查(透视86例次占41%,仅摄片126例次占59%);仅摄片定义为经管注入对比剂后行腹部正侧位摄片,透视定义为放射科医生在透视室完成的检查;以操作当天及长期临床随访记录作为不良事件参考标准。
诊断标准与关键数值
- 透视检查对管异位的敏感度为100%(6/6;95%CI:100%,100%),特异度为100%(80/80;95%CI:100%,100%)。
- 仅摄片检查对管异位的敏感度为75%(3/4;95%CI:33%,100%),特异度为100%(112/112;95%CI:100%,100%)。
- 最常被正确识别的不良事件为管异位(9例真阳性),最常被漏诊的不良事件为管周渗漏(8例假阴性)。
临床应用与阅片要点
- 仅摄片检查可作为评估胃造瘘管或胃空肠造瘘管异位的影像方法,其敏感度和特异度与透视检查相似。
- 阅片时需注意管周渗漏是最常被漏诊的不良事件。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Gastrostomy (G) tube or gastrojejunostomy (GJ) tube checks are radiographic procedures that are frequently ordered to confirm tube positioning.
OBJECTIVE: To characterize the sensitivity and specificity of radiograph-only examinations and traditional radiologist-performed fluoroscopy exams for G-tube or GJ-tube malposition and other adverse events detectable by imaging.
MATERIALS AND METHODS: We performed a retrospective cohort study at a single tertiary pediatric center that included all subjects who underwent G-tube or GJ-tube checks using fluoroscopy or radiograph-only exams between January 1, 2008, and January 1, 2019. Radiograph-only examinations were defined as checks that consist of frontal and lateral abdominal radiographs after injection of contrast through the G-tube or GJ-tube. Fluoroscopy exams were defined as exams performed by a radiologist in the fluoroscopy suite. Radiology reports were evaluated for reported tube malposition and for other adverse events that are detectable by imaging. Clinical notes from the day of the procedure and longer-term clinical follow-up notes were used as a reference standard for adverse events. The sensitivity and specificity of the two procedures were calculated.
RESULTS: A total of 212 exams, including 86 (41%) fluoroscopy exams and 126 (59%) radiograph-only exams, were evaluated. The most common correctly identified adverse event was tube malposition (9 true positives). The most commonly missed adverse event was leakage around the tube (8 false negatives). Fluoroscopy exams had a sensitivity of 100% (6/6; 95% CI: 100%, 100%) and a specificity of 100% (80/80; 95% CI: 100%, 100%) for tube malposition, while radiograph-only exams had 75% sensitivity (3/4; 95% CI: 33%,100%) and 100% specificity (112/112; 95% CI: 100%, 100%).
CONCLUSIONS: Fluoroscopy and radiograph-only exams have similar sensitivity and specificity for detecting G-tube or GJ-tube malposition.
引用
- Tompe, Lee, Noel-Macdonnell, et al. Retrospective cohort comparison between fluoroscopic and radiograph-only exams for evaluation of gastrostomy and gastrojejunostomy tubes. Pediatr Radiol. 2023. PMID: 37410121. doi:10.1007/s00247-023-05708-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。