细胞外基质硬度驱动的肝癌血管生成:对影像研究的启示
研究采用两种大鼠肝细胞癌模型,用二维剪切波弹性成像、动态对比增强超声和增强CT评估肿瘤硬度与灌注,并用原子力显微镜和CD34免疫组化分析血管特征。结果显示较软的Buffalo-McA-RH7777肿瘤血管更丰富、周边分布为主且强化更明显,较硬的SD-N1S1肿瘤微血管稀疏;动态对比增强超声与增强CT灌注参数呈正相关。
要点
- 较软的Buffalo-McA-RH7777肿瘤比较硬的SD-N1S1肿瘤强化更明显。
- 较硬SD-N1S1肿瘤微血管网络稀疏,较软Buffalo-McA-RH7777肿瘤血管丰富且以周边分布为主。
- 动态对比增强超声与增强CT的总曲线下面积和微血管覆盖率百分比呈正相关。
核心结论
- 肿瘤硬度特征对应不同血管表型,二维剪切波弹性成像和动态对比增强超声可充分显示不同间质模式,较软肿瘤的对比强化显著更强。
研究设计与样本
- 动物实验研究,使用Buffalo-McA-RH7777和Sprague Dawley-N1S1两种大鼠肝细胞癌肿瘤模型,以二维剪切波弹性成像评估肿瘤硬度,动态对比增强超声和增强CT评估肿瘤灌注,原子力显微镜计算亚微米尺度肿瘤硬度,计算机辅助图像分析评估肿瘤坏死及CD34+血管百分比、分布和厚度。
关键影像表现/征象
- 二维剪切波弹性成像和原子力显微镜显示两种模型硬度值分布不同(P < 0.05)。
- 较高硬度值见于SD-N1S1肿瘤,伴稀疏微血管网络(P ≤ 0.001)。
- Buffalo-McA-RH7777模型硬度值较低,血管更丰富且以周边分布为主(P = 0.03)。
- Buffalo-McA-RH7777肿瘤在动态对比增强超声和增强CT上的强化均显著大于SD-N1S1(P < 0.005)。
诊断标准与关键数值
- 动态对比增强超声与增强CT的总曲线下面积和微血管肿瘤覆盖率百分比之间呈统计学显著正相关(P < 0.05)。
临床应用与阅片要点
- 二维剪切波弹性成像和动态对比增强超声可显示不同间质模式及其对应的灌注参数差异。
- 较软肿瘤的对比强化显著强于较硬肿瘤,阅片时需结合硬度评估血管表型。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Extracellular matrix stiffness represents a barrier to effective local and systemic drug delivery. Increasing stiffness disrupts newly formed vessel architecture and integrity, leading to tumor-like vasculature. The resulting vascular phenotypes are manifested through different cross-sectional imaging features. Contrast-enhanced studies can help elucidate the interplay between liver tumor stiffness and different vascular phenotypes.
PURPOSE: This study aims to correlate extracellular matrix stiffness, dynamic contrast-enhanced computed tomography, and dynamic contrast-enhancement ultrasound imaging features of 2 rat hepatocellular carcinoma tumor models.
METHODS AND MATERIALS: Buffalo-McA-RH7777 and Sprague Dawley (SD)-N1S1 tumor models were used to evaluate tumor stiffness by 2-dimensional shear wave elastography, along with tumor perfusion by dynamic contrast-enhanced ultrasonography and contrast-enhanced computed tomography. Atomic force microscopy was used to calculate tumor stiffness at a submicron scale. Computer-aided image analyses were performed to evaluate tumor necrosis, as well as the percentage, distribution, and thickness of CD34+ blood vessels.
RESULTS: Distinct tissue signatures between models were observed according to the distribution of the stiffness values by 2-dimensional shear wave elastography and atomic force microscopy ( P < 0.05). Higher stiffness values were attributed to SD-N1S1 tumors, also associated with a scant microvascular network ( P ≤ 0.001). Opposite results were observed in the Buffalo-McA-RH7777 model, exhibiting lower stiffness values and richer tumor vasculature with predominantly peripheral distribution ( P = 0.03). Consistent with these findings, tumor enhancement was significantly greater in the Buffalo-McA-RH7777 tumor model than in the SD-N1S1 on both dynamic contrast-enhanced ultrasonography and contrast-enhanced computed tomography ( P < 0.005). A statistically significant positive correlation was observed between tumor perfusion on dynamic contrast-enhanced ultrasonography and contrast-enhanced computed tomography in terms of the total area under the curve and % microvessel tumor coverage ( P < 0.05).
CONCLUSIONS: The stiffness signatures translated into different tumor vascular phenotypes. Two-dimensional shear wave elastography and dynamic contrast-enhanced ultrasonography adequately depicted different stromal patterns, which resulted in unique imaging perfusion parameters with significantly greater contrast enhancement observed in softer tumors.
引用
- Taiji, Cortes, Zaske, et al. Liver Cancer Vascularity Driven by Extracellular Matrix Stiffness: Implications for Imaging Research. Invest Radiol. 2023. PMID: 37403975. doi:10.1097/RLI.0000000000001001
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。