光子计数探测器CT的心脏虚拟平扫图像用于钙化定量
本研究评估了光子计数探测器CT延迟增强扫描重建的虚拟平扫图像对主动脉瓣钙化、二尖瓣环钙化和冠状动脉钙化定量的准确性及风险分层能力。结果显示,80 keV联合QIR 4的虚拟平扫图像对主动脉瓣钙化和二尖瓣环钙化、70 keV联合QIR 4的虚拟平扫图像对冠状动脉钙化的定量与真实平扫图像相似,且钙化分级一致性极好。
要点
- 80 keV联合QIR 4的虚拟平扫图像可准确量化主动脉瓣钙化和二尖瓣环钙化。
- 70 keV联合QIR 4的虚拟平扫图像可准确量化冠状动脉钙化。
- 虚拟平扫图像对钙化分级与真实平扫图像一致性极好,支持风险分层。
核心结论
- 心脏光子计数探测器CT的虚拟平扫图像能够实现患者风险分层,并准确量化主动脉瓣钙化、二尖瓣环钙化和冠状动脉钙化。
研究设计与样本
- 回顾性、经机构审查委员会批准的研究,纳入2022年1月至9月期间接受光子计数探测器CT检查的患者90例(平均年龄80岁±8[SD],男性49例)。
诊断标准与关键数值
- 主动脉瓣钙化:80 keV联合QIR 4的虚拟平扫图像与真实平扫图像平均差异为3,ICC=0.992,r=0.98。
- 二尖瓣环钙化:80 keV联合QIR 4的虚拟平扫图像与真实平扫图像平均差异为6,ICC=0.998,r=0.99。
- 冠状动脉钙化:70 keV联合QIR 4的虚拟平扫图像与真实平扫图像平均差异为28,ICC=0.996,r=0.99。
- 严重主动脉瓣狭窄可能性分级一致性:80 keV虚拟平扫图像κ=0.974。
- 冠状动脉钙化风险分级一致性:70 keV虚拟平扫图像κ=0.967。
临床应用与阅片要点
- 可用80 keV联合QIR 4的虚拟平扫图像定量主动脉瓣钙化和二尖瓣环钙化,替代真实平扫。
- 可用70 keV联合QIR 4的虚拟平扫图像定量冠状动脉钙化,替代真实平扫。
- 虚拟平扫图像可用于严重主动脉瓣狭窄可能性及冠状动脉钙化风险的分级评估。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess the accuracy of aortic valve calcium (AVC), mitral annular calcium (MAC), and coronary artery calcium (CAC) quantification and risk stratification using virtual noncontrast (VNC) images from late enhancement photon-counting detector CT as compared with true noncontrast images.
MATERIALS AND METHODS: This retrospective, institutional review board-approved study evaluated patients undergoing photon-counting detector CT between January and September 2022. VNC images were reconstructed from late enhancement cardiac scans at 60, 70, 80, and 90 keV using quantum iterative reconstruction (QIR) strengths of 2-4. AVC, MAC, and CAC were quantified on VNC images and compared with quantification of AVC, MAC, and CAC on true noncontrast images using Bland-Altman analyses, regression models, intraclass correlation coefficients (ICC), and Wilcoxon tests. Agreement between severe aortic stenosis likelihood categories and CAC risk categories determined from VNC and true noncontrast images was assessed by weighted κ analysis.
RESULTS: Ninety patients were included (mean age, 80 years ± 8 [SD]; 49 male patients). Scores were similar on true noncontrast images and VNC images at 80 keV for AVC and MAC, regardless of QIR strengths, and VNC images at 70 keV with QIR 4 for CAC (all P > .05). The best results were achieved using VNC images at 80 keV with QIR 4 for AVC (mean difference, 3; ICC = 0.992; r = 0.98) and MAC (mean difference, 6; ICC = 0.998; r = 0.99), and VNC images at 70 keV with QIR 4 for CAC (mean difference, 28; ICC = 0.996; r = 0.99). Agreement between calcification categories was excellent on VNC images at 80 keV for AVC (κ = 0.974) and on VNC images at 70 keV for CAC (κ = 0.967).
CONCLUSION: VNC images from cardiac photon-counting detector CT enables patient risk stratification and accurate quantification of AVC, MAC, and CAC.Keywords: Coronary Arteries, Aortic Valve, Mitral Valve, Aortic Stenosis, Calcifications, Photon-counting Detector CT Supplemental material is available for this article © RSNA, 2023.
引用
- Mergen, Ghouse, Sartoretti, et al. Cardiac Virtual Noncontrast Images for Calcium Quantification with Photon-counting Detector CT. Radiol Cardiothorac Imaging. 2023. PMID: 37404795. doi:10.1148/ryct.220307
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。