文献速递骨肌技术与安全CT

光子计数探测器CT脊柱后路固定术后光谱金属伪影减少研究

Spectral metal artifact reduction after posterior spinal fixation in photon-counting detector CT datasets.
PubMed 文献 · Eur J Radiol · 2023-06-20

本回顾性队列研究纳入23例脊柱后路固定术后患者,采用新型光子计数探测器CT扫描并重建60-190 keV范围内14组虚拟单能图像,计算伪影指数。结果显示110 keV时整体伪影指数最低(32.5),低于或高于此能级伪影指数均升高;邻近较大金属部件的区域高能级处条纹伪影重现。

要点

  • 110 keV为整体金属伪影抑制的最优虚拟单能图像能级。
  • 邻近较大金属部件的区域,高能级处条纹伪影重现致伪影指数升高。
  • 特定解剖区域可略微调高能级以获得更好伪影抑制效果。

核心结论

  • 研究提示110 keV是整体伪影抑制的最优虚拟单能图像设置,但特定解剖区域略微调高能级可能获得更好结果。

研究设计与样本

  • 回顾性队列研究,纳入23例脊柱后路固定术后患者,采用新型光子计数探测器CT(NAEOTOM Alpha,Siemens Healthineers,Erlangen,德国)行常规临床扫描,重建60-190 keV范围内以10 keV为间隔的14组虚拟单能图像。

关键影像表现/征象

  • 在12个围绕一对椎弓根螺钉的选定位置及均匀脂肪区测量CT值均值和标准差并计算伪影指数。
  • 整体而言,110 keV时伪影指数最低(32.5(27.8-37.9))。
  • 在较低和较高keV能级,伪影指数均升高。
  • 邻近较大金属部件的区域,高能级端伪影指数升高主要由条纹伪影重现所致。

诊断标准与关键数值

  • 110 keV时整体伪影指数为32.5(27.8-37.9),与≤90 keV(p < 0.001)及≥160 keV(p < 0.015)相比差异有统计学意义。
  • 各别位置表现为随keV升高伪影指数单调下降,或在中间能级(100-140 keV)出现伪影指数最低值。

临床应用与阅片要点

  • 日常阅片重建脊柱后路固定术后光子计数探测器CT虚拟单能图像时,可优先选用110 keV以整体抑制金属伪影。
  • 邻近较大金属部件的特定解剖区域,可略微调高能级以改善伪影抑制效果。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To investigate the usefulness of virtual monoenergetic image (VMI) reconstructions derived from scans on a novel photon-counting detector CT (PCD-CT) for artifact reduction in patients after posterior spinal fixation.

METHODS: This retrospective cohort study included 23 patients status post posterior spinal fixation. Subjects were scanned on a novel PCD-CT (NAEOTOM Alpha, Siemens Healthineers, Erlangen, Germany) as part of routine clinical care. 14 sets of VMI reconstructions were derived in 10 keV increments for the interval 60-190 keV. The mean and the standard deviation (SD) of CT-values in 12 defined locations around a pair of pedicle screws on one vertebral level and the SD of homogenous fat were measured and used to calculate an artifact index (AIx).

RESULTS: Averaged over all regions, the lowest AIx was observed at VMI levels of 110 keV (32.5 (27.8-37.9)) which was significantly different from those of VMIs ≤ 90 keV (p < 0.001) or ≥160 keV (p < 0.015), respectively. Overall AIx values increased in both lower- and higher-keV levels. Regarding individual locations, either a monotonous AIx-decrease for increasing keV values or an AIx-minimum in intermediate-keV levels (100-140 keV) was found. In locations adjacent to larger metal parts, the increase of AIx values at the high-end of the keV spectrum was mainly explained by a reappearance of streak artifacts.

CONCLUSION: Our findings suggest that 110 keV is the optimal VMI setting for overall artifact suppression. In specific anatomical regions, however, slight adjustments towards higher-keV levels may provide better results.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Popp, Sinzinger, Decker, et al. Spectral metal artifact reduction after posterior spinal fixation in photon-counting detector CT datasets. Eur J Radiol. 2023. PMID: 37399668. doi:10.1016/j.ejrad.2023.110946

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。