文献速递泌尿生殖MR

深度学习图像重建加速前列腺扩散加权成像:与标准扩散加权成像的回顾性比较

Accelerated diffusion-weighted imaging of the prostate using deep learning image reconstruction: A retrospective comparison with standard diffusion-weighted imaging.
PubMed 文献 · Eur J Radiol · 2023-06-28

该回顾性研究对2022年9月至2023年1月间在一家德国三级医院连续接受前列腺MRI患者的DWI原始数据进行标准重建与深度学习重建,模拟采集时间缩短39%。三位放射科医师评估及客观指标显示,深度学习重建在b=0 s/mm²图像和ADC图上噪声更低,整体信噪比相似,仅移行带信号比略降低,结论为深度学习重建可在不损失图像质量的前提下将前列腺DWI采集时间缩短39%。

要点

  • 深度学习重建可在不损失图像质量的前提下将前列腺DWI采集时间缩短39%。
  • 在b=0 s/mm²图像和ADC图上,深度学习重建图像噪声更低,读者间一致性良好。
  • 整体信噪比相似,但移行带信噪比在深度学习重建后略降低。

核心结论

  • 使用深度学习图像重建可在不损失图像质量的前提下将前列腺DWI采集时间缩短39%。

研究设计与样本

  • 回顾性研究,纳入35例(共147例经排除标准筛选)于2022年9月至2023年1月在一家德国三级医院连续接受前列腺MRI的患者,对DWI原始数据分别进行标准重建和深度学习重建,模拟采集时间缩短39%(b=0 s/mm²采用1次而非2次平均,b=1000 s/mm²采用6次而非10次平均)。

关键影像表现/征象

  • 三位放射科医师主观评估认为,深度学习重建的b=0 s/mm²图像和ADC图噪声更少,读者间一致性良好。
  • 整体信噪比相似,移行带信噪比在深度学习重建后略降低。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Routine multiparametric MRI of the prostate reduces overtreatment and increases sensitivity in the diagnosis of the most common solid cancer in men. However, the capacity of MRI systems is limited. Here we investigate the ability of deep learning image reconstruction to accelerate time consuming diffusion-weighted imaging (DWI) acquisition while maintaining diagnostic image quality.

METHOD: In this retrospective study, raw data of DWI sequences of consecutive patients undergoing MRI of the prostate at a tertiary care hospital in Germany were reconstructed using standard and deep learning reconstruction. To simulate a shortening of acquisition times by 39 %, one instead of two and six instead of ten averages were used in the reconstruction of b = 0 and 1000 s/mm2 images, respectively. Image quality was assessed by three radiologists and objective image quality metrics.

RESULTS: After the application of exclusion criteria, 35 out of 147 patients examined between September 2022 and January 2023 were included in this study. The radiologists perceived less image noise on deep learning reconstructed images at b = 0 s/mm2 images and ADC maps with good inter-reader agreement. Signal-to-noise ratios were similar overall with discretely reduced values in the transitional zone after deep learning reconstruction.

CONCLUSIONS: An acquisition time reduction of 39 % without loss in image quality is feasible in DWI of the prostate when using deep learning image reconstruction.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Ursprung, Herrmann, Joos, et al. Accelerated diffusion-weighted imaging of the prostate using deep learning image reconstruction: A retrospective comparison with standard diffusion-weighted imaging. Eur J Radiol. 2023. PMID: 37399667. doi:10.1016/j.ejrad.2023.110953

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。