文献速递技术与安全腹部US

上消化道内镜操作患者常规床旁胃超声的可行性与实用性:一项前瞻性队列研究

Feasibility and Utility of Routine Point-of-Care Gastric Ultrasonography in Patients Undergoing Upper Gastrointestinal Endoscopy Procedures: A Prospective Cohort Study.
PubMed 文献 · J Ultrasound Med · 2023-07-04

单中心前瞻性队列研究纳入83例上消化道内镜患者,麻醉前用床旁胃超声定性判断胃内容物安全与否,并与内镜吸引量及公式/列线图估测的残余胃容量相关。定性扫查一致判定安全与不安全内容物,83例中4例(5%)虽空腹达标但定性扫查判为不安全;实测胃容量与列线图(r=0.40,95%CI 0.20~0.57,P=0.0002)及公式(r=0.38,95%CI 0.17~0.55,P=0.0004)估测值仅呈中等相关。作者认为定性床旁胃超声是识别上消化道内镜前误吸风险患者的可行且有用技术。

要点

  • 麻醉前定性床旁胃超声可判定胃残余内容物安全与否,83例中4例(5%)空腹达标但判为不安全。
  • 实测胃容量与列线图估测仅中等相关(r=0.40,95%CI 0.20~0.57,P=0.0002)。
  • 实测胃容量与公式估测仅中等相关(r=0.38,95%CI 0.17~0.55,P=0.0004)。

核心结论

  • 作者认为,日常临床实践中定性床旁胃超声判定胃残余内容物是识别上消化道内镜前误吸风险患者的可行且有用技术。

研究设计与样本

  • 单中心前瞻性队列研究,纳入83例上消化道内镜患者,麻醉前扫查胃窦测定横截面积(CSA)并定性判定内容物安全与否,用公式和列线图法估测残余胃容量,再与内镜吸引的胃分泌物量相关。

诊断标准与关键数值

  • 定性床旁胃超声在83例中一致判定安全与不安全胃残余内容物,83例中4例(5%)空腹达标但定性扫查判为不安全。

临床应用与阅片要点

  • 除床旁超声判为不安全内容物者改用快速序贯诱导外,无患者需改变主要麻醉方案;定性床旁胃超声可用于上消化道内镜前识别误吸风险患者(作者结论)。

局限性

  • 实测胃容量与列线图估测仅中等相关(r=0.40,95%CI 0.20~0.57,P=0.0002)。
  • 实测胃容量与公式估测仅中等相关(r=0.38,95%CI 0.17~0.55,P=0.0004)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Previous studies have indicated that point-of-care ultrasonography (POCUS) of the gastric antrum can predict the adequacy of fasting before surgery and anesthesia. The aim of this study was to evaluate the utility of gastric POCUS in patients undergoing upper gastrointestinal (GI) endoscopy procedures.

METHODS: We performed a single-center cohort study in patients undergoing upper GI endoscopy. Consenting patient's gastric antrum was scanned before anesthetic care for endoscopy to determine the cross-sectional area (CSA) and qualitatively determine safe and unsafe contents. Further, an estimate of residual gastric volume was determined using the formula and the nomogram methods. Subsequently, gastric secretions aspirated during endoscopy were quantified and further correlated with nomogram and formula-based assessments. No patient required a change in the primary anesthetic plan except for using rapid sequence induction in those with unsafe contents on POCUS scans.

RESULTS: Qualitative ultrasound measurements consistently determined safe and unsafe gastric residual contents in 83 patients enrolled in the study. Unsafe contents were determined by qualitative scans in 4 out of 83 cases (5%) despite adequate fasting status. Quantitatively, only a moderate correlation was demonstrated between measured gastric volumes and nomogram (r = .40, 95% CI: 0.20, 0.57; P = .0002) or formula-based (r = .38, 95% CI: 0.17, 0.55; P = .0004) determinations of residual gastric volumes.

CONCLUSION: In daily clinical practice, qualitative POCUS determination of residual gastric content is a feasible and useful technique to identify patients at risk of aspiration before upper GI endoscopy procedures.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Kalagara, Sondekoppam, Ahmed, et al. Feasibility and Utility of Routine Point-of-Care Gastric Ultrasonography in Patients Undergoing Upper Gastrointestinal Endoscopy Procedures: A Prospective Cohort Study. J Ultrasound Med. 2023. PMID: 37401538. doi:10.1002/jum.16299

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。