锁骨上臂丛神经阻滞围术期同侧与对侧半膈肌变化的前瞻性观察研究
这项前瞻性观察队列纳入64例拟行锁骨上臂丛神经阻滞(肌间沟或锁骨上入路)的肩部手术成人患者,术前后用超声测量双侧半膈肌增厚分数(TF)。阻滞后对侧TF平均增加40%(p=0.001),同侧TF平均下降72%;86%患者同侧TF下降、59%对侧TF增加,仅17%发生术后肺部并发症。作者结论认为对侧半膈肌功能代偿增加使整体膈肌功能下降小于预期,作为膈肌功能的一部分,对侧半膈肌功能必须检查。
要点
- 锁骨上臂丛神经阻滞后同侧半膈肌增厚分数平均下降72%,对侧平均增加40%。
- 术后86%患者同侧TF下降、59%患者对侧TF增加,仅17%出现术后肺部并发症。
- 超声评估膈肌功能时应同时测量阻滞对侧半膈肌增厚分数。
核心结论
- 锁骨上臂丛神经阻滞后整体膈肌功能因同侧半膈肌运动减弱而下降,但因对侧半膈肌功能增加而下降幅度小于预期;作为膈肌功能的一部分,对侧半膈肌功能必须检查。
研究设计与样本
- 前瞻性观察队列研究,纳入64例拟行锁骨上臂丛神经阻滞(肌间沟臂丛阻滞和锁骨上阻滞)的肩部手术成人患者,术前及术后用超声测量同侧与对侧半膈肌增厚分数(TF),TFglobal为同侧与对侧TF之和;术后肺部并发症定义为出现呼吸困难、呼吸急促、SpO2<90%或SpO2/FiO2<315。
诊断标准与关键数值
- 术后肺部并发症定义为出现呼吸困难、呼吸急促、SpO2<90%或SpO2/FiO2<315;超声测量指标为半膈肌增厚分数(TF),TFglobal为同侧与对侧TF之和。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Hemi-diaphragm palsy after brachial plexus block above the clavicle (BPBAC) occurs frequently, but few patients develop post-operative pulmonary complications (PPC). We hypothesized that contralateral hemidiaphragm function increases after BPBAC. This contralateral function preserves global diaphragmatic function, avoiding PPC in the case of ipsilateral hemi-diaphragm palsy.
METHODS: This prospective observational cohort study included 64 adult patients undergoing shoulder surgery with planned BPBAC (interscalene brachial plexus block and supraclavicular block). The Thickening Fraction (TF) was measured by ultrasound in both hemi-diaphragms, ipsilateral (TF ipsilateral) and contralateral (TFcontralateral) to the BPBAC, before and after the surgery. TFglobal is the sum of TFipsilateral and TFcontralateral. PPC were defined as occurrences of dyspnea, tachypnea, SpO2 <90% or SpO2/FiO2 <315.
RESULTS: TFcontralateral increased significantly (an average of 40%) after BPBAC (p = 0.001), and TFipsilateral decreased (an average of 72%). After BPBAC, 86% of patients had a decreased TFipsilateral and 59% of patients an increased TFcontralateral at post-operatively. Only 17% of patients have PPC.
CONCLUSION: After BPBAC, global diaphragm function decreases because of ipsilateral hemi-diaphragm reduction, but less than expected because of increased contralateral hemi-diaphragm function. As a part of diaphragm function, contralateral hemi-diaphragm function must be checked.
引用
- Rovira, Kot, Pozo, et al. Peri-operative Hemi-diaphragmatic Variations After Brachial Plexus Block Above the Clavicle: A Prospective Observational Study of the Contralateral Side. Ultrasound Med Biol. 2023. PMID: 37394374. doi:10.1016/j.ultrasmedbio.2023.05.018
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。