低表观扩散系数像素截止技术计算扩散加权成像用于乳腺癌检测
本研究回顾性评估87例恶性乳腺病变和72例阴性乳腺病变患者,比较低ADC像素截止技术计算DWI(cDWI cut-off)与实测DWI(mDWI)的图像质量和诊断性能。结果显示cDWI cut-off在b值1200或1500 s/mm2时对比度优于mDWI,乳腺癌检测AUC为0.909 vs 0.837(p<.01),结论认为cDWI cut-off诊断性能更好。
要点
- 低ADC像素截止技术可改善脂肪抑制(p<.05)并提高乳腺癌与腺体组织对比度(p<.01)。
- cDWI cut-off检测乳腺癌AUC为0.909,高于mDWI的0.837(p<.01)。
- b值1200或1500 s/mm2的cDWI cut-off对比度优于mDWI。
核心结论
- cDWI cut-off在乳腺癌检测方面诊断性能优于mDWI。
研究设计与样本
- 回顾性评估87例连续恶性乳腺病变患者和72例阴性乳腺病变患者,比较cDWI cut-off与mDWI。
关键影像表现/征象
- 应用ADC截止阈值0.3或0.6(×10-3 mm2/s)时脂肪抑制显著改善(p<.05)。
- b值1200或1500 s/mm2的cDWI cut-off对比度优于mDWI(p<.01)。
诊断标准与关键数值
- 乳腺癌检测AUC:mDWI为0.837,cDWI cut-off为0.909(p<.01)。
- cDWI基于b值800、1200、1500 s/mm2及ADC截止阈值none、0、0.3、0.6(×10-3 mm2/s)生成。
临床应用与阅片要点
- 低ADC像素截止技术可提高对比度并消除未抑制脂肪信号,从而改善诊断性能。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: This study aimed to compare the image quality and diagnostic performance of computed diffusion-weighted imaging (DWI) with low-apparent diffusion coefficient (ADC)-pixel cut-off technique (cDWI cut-off) and actual measured DWI (mDWI).
METHODS: Eighty-seven consecutive patients with malignant breast lesions and 72 with negative breast lesions who underwent breast MRI were retrospectively evaluated. Computed DWI with high b-values of 800, 1200, and 1500 s/mm2 and ADC cut-off thresholds of none, 0, 0.3, and 0.6 (×10-3 mm2/s) were generated from DWI with two b-values (0 and 800 s/mm2). To identify the optimal conditions, two radiologists evaluated the fat suppression and lesion reduction failure using a cut-off technique. The contrast between breast cancer and glandular tissue was evaluated using region of interest analysis. Three other board-certified radiologists independently assessed the optimised cDWI cut-off and mDWI data sets. Diagnostic performance was evaluated using receiver operating characteristic (ROC) analysis.
RESULTS: When an ADC cut-off threshold of 0.3 or 0.6 (× 10-3 mm2/s) was applied, fat suppression improved significantly (p < .05). The contrast of the cDWI cut-off with a b-value of 1200 or 1500 s/mm2 was better than the mDWI (p < .01). The ROC area under the curve for breast cancer detection was 0.837 for the mDWI and 0.909 for the cDWI cut-off (p < .01).
CONCLUSION: The cDWI cut-off provided better diagnostic performance than mDWI for breast cancer detection.
ADVANCES IN KNOWLEDGE: Using the low-ADC-pixel cut-off technique, computed DWI can improve diagnostic performance by increasing contrast and eliminating un-suppressed fat signals.