基于CT的影像组学预测肺结节恶性程度:系统综述与Meta分析
该系统综述与Meta分析纳入49项研究进行方法学质量评价,其中27项进入定量合成,评估基于CT的影像组学模型预测肺结节恶性程度的表现。合并敏感度0.86(95%CI 0.79-0.91)、特异度0.84(95%CI 0.78-0.88)、诊断比值比31.55(95%CI 21.31-46.70),总体AUC为0.91(95%CI 0.89-0.94)。Meta回归显示结节类型是异质性来源,仅纳入实性结节的研究中模型表现更好。
要点
- CT影像组学模型预测肺结节恶性的合并AUC为0.91,合并敏感度0.86、特异度0.84。
- 49项纳入研究的方法学质量中位RQS为13分(范围-2至20),总体偏倚风险高。
- 结节类型是异质性来源,仅纳入实性结节的研究中模型诊断表现更好。
核心结论
- 基于CT的影像组学模型在预测肺结节恶性程度方面表现出优异的诊断性能;需要前瞻性、大样本、设计良好的研究来验证其预测能力。
研究设计与样本
- 系统综述与Meta分析,检索PubMed、Embase和Web of Science数据库,49项研究纳入定性分析、27项纳入定量合成。
诊断标准与关键数值
- 合并敏感度0.86(95%CI 0.79-0.91)。
- 合并特异度0.84(95%CI 0.78-0.88)。
- 合并诊断比值比31.55(95%CI 21.31-46.70)。
- 总体AUC为0.91(95%CI 0.89-0.94)。
局限性
- 49项研究的方法学质量中位RQS为13(范围-2至20)。
- 总体偏倚风险高。
- 总体适用性关注度低。
- 需要前瞻性、大样本、设计良好的研究来验证CT影像组学模型的预测能力。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: More pulmonary nodules (PNs) have been detected with the wide application of computed tomography (CT) in lung cancer screening. Radiomics is a noninvasive approach to predict the malignancy of PNs. We aimed to systematically evaluate the methodological quality of the eligible studies regarding CT-based radiomics models in predicting the malignancy of PNs and evaluate the model performance of the available studies.
MATERIALS AND METHODS: PubMed, Embase, and Web of Science were searched to retrieve relevant studies. The methodological quality of the included studies was assessed using the Radiomics Quality Score (RQS) and Prediction model Risk of Bias Assessment Tool. A meta-analysis was conducted to evaluate the performance of CT-based radiomics model. Meta-regression and subgroup analyses were employed to investigate the source of heterogeneity.
RESULTS: In total, 49 studies were eligible for qualitative analysis and 27 studies were included in quantitative synthesis. The median RQS of 49 studies was 13 (range -2 to 20). The overall risk of bias was found to be high, and the overall applicability was of low concern in all included studies. The pooled sensitivity, specificity, and diagnostic odds ratio were 0.86 95% confidence interval (CI): 0.79-0.91, 0.84 95% CI: 0.78-0.88, and 31.55 95% CI: 21.31-46.70, respectively. The overall area under the curve was 0.91 95% CI: 0.89-0.94. Meta-regression showed the type of PNs on heterogeneity. CT-based radiomics models performed better in studies including only solid PNs.
CONCLUSION: CT-based radiomics models exhibited excellent diagnostic performance in predicting the malignancy of PNs. Prospective, large sample size, and well-devised studies are desired to verify the prediction capabilities of CT-based radiomics model.
引用
- Shi, Sheng, Wei, et al. CT-Based Radiomics Predicts the Malignancy of Pulmonary Nodules: A Systematic Review and Meta-Analysis. Acad Radiol. 2023. PMID: 37385850. doi:10.1016/j.acra.2023.05.026
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。