文献速递外周血管介入CTDSA

下肢动脉CT血管成像中高矩阵重建对图像质量影响的首次评估

First experience of evaluation of the impact of high-matrix size reconstruction in image quality in arterial CT runoff studies of the lower extremities.
PubMed 文献 · Eur Radiol · 2023-06-29

本研究回顾性收集50例下肢CTA原始数据,分别以标准512×512和更高矩阵768×768、1024×1024重建,由5名盲法读者对图像质量评分。结果显示1024×1024矩阵在血管壁显示、噪声感知和狭窄分级信心上均显著优于512×512,且胫动脉等远端小血管获益大于股腘动脉;10例与DSA对照的狭窄分级准确性无显著差异。

要点

  • 高矩阵重建(768×768、1024×1024)可提升下肢CTA的血管壁显示和阅片信心。
  • 胫腓等远端小血管的图像质量获益大于股腘动脉。
  • 1024×1024矩阵不增加主观感知的图像噪声。

关键影像表现/征象

  • 1024×1024矩阵重建在血管壁显示、噪声感知和狭窄分级信心上的平均评分均显著高于512×512。
  • 胫动脉中768×768和1024×1024矩阵较512×512改善血管壁显示和信心(p<0.05),噪声差异无统计学意义(p=0.06)。
  • 股腘动脉中高矩阵与512×512的图像质量评分差异均无统计学意义(p>0.05)。
  • 读者间一致性为中等(rho=0.5)。

诊断标准与关键数值

  • 图像质量评分采用0(最差)至100(最佳)分,分别评价血管壁显示、图像噪声和狭窄分级信心。
  • 1024×1024矩阵:血管壁显示平均分72(95%CI 61-84),噪声74(95%CI 59-88),信心70(95%CI 59-80)。
  • 512×512矩阵:血管壁显示平均分65(95%CI 53-77),噪声67(95%CI 52-81),信心62(95%CI 52-73)。
  • 1024×1024与512×512比较,血管壁显示p=0.003、噪声p=0.01、信心p=0.004。
  • 10例患者中,CTA与侵入性血管造影的狭窄分级准确性无显著差异。

临床应用与阅片要点

  • 对下肢CTA,尤其关注胫腓动脉等远端小血管时,可优先选用768×768或1024×1024矩阵重建。
  • 高矩阵重建未主观增加图像噪声,可放心用于日常阅片。
  • 股腘动脉的图像质量获益有限,不必常规依赖高矩阵重建。
  • 高矩阵主要提升主观图像质量和阅片信心,对狭窄分级准确性的影响需更大样本验证。

局限性

  • 回顾性研究,样本量有限(50例,其中仅10例有血管造影对照)。
  • 读者间一致性仅为中等(rho=0.5)。
  • 未报告设备间差异及重建时间等对临床流程的影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To determine whether image reconstruction with a higher matrix size improves image quality for lower extremity CTA studies.

METHODS: Raw data from 50 consecutive lower extremity CTA studies acquired on two MDCT scanners (SOMATOM Flash, Force) in patients evaluated for peripheral arterial disease (PAD) were retrospectively collected and reconstructed with standard (512 × 512) and higher resolution (768 × 768, 1024 × 1024) matrix sizes. Five blinded readers reviewed representative transverse images in randomized order (150 total). Readers graded image quality (0 (worst)-100 (best)) for vascular wall definition, image noise, and confidence in stenosis grading. Ten patients' stenosis scores on CTA images were compared to invasive angiography. Scores were compared using mixed effects linear regression.

RESULTS: Reconstructions with 1024 × 1024 matrix were ranked significantly better for wall definition (mean score 72, 95% CI = 61-84), noise (74, CI = 59-88), and confidence (70, CI = 59-80) compared to 512 × 512 (wall = 65, CI = 53 × 77; noise = 67, CI = 52 × 81; confidence = 62, CI = 52 × 73; p = 0.003, p = 0.01, and p = 0.004, respectively). Compared to 512 × 512, the 768 × 768 and 1024 × 1024 matrix improved image quality in the tibial arteries (wall = 51 vs 57 and 59, p < 0.05; noise = 65 vs 69 and 68, p = 0.06; confidence = 48 vs 57 and 55, p < 0.05) to a greater degree than the femoral-popliteal arteries (wall = 78 vs 78 and 85; noise = 81 vs 81 and 84; confidence = 76 vs 77 and 81, all p > 0.05), though for the 10 patients with angiography accuracy of stenosis grading was not significantly different. Inter-reader agreement was moderate (rho = 0.5).

CONCLUSION: Higher matrix reconstructions of 768 × 768 and 1024 × 1024 improved image quality and may enable more confident assessment of PAD.

CLINICAL RELEVANCE STATEMENT: Higher matrix reconstructions of the vessels in the lower extremities can improve perceived image quality and reader confidence in making diagnostic decisions based on CTA imaging.

KEY POINTS: • Higher than standard matrix sizes improve perceived image quality of the arteries in the lower extremities. • Image noise is not perceived as increased even at a matrix size of 1024 × 1024 pixels. • Gains from higher matrix reconstructions are higher in smaller, more distal tibial and peroneal vessels than in femoropopliteal vessels.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Schwartz, Ronald, Kalisz, et al. First experience of evaluation of the impact of high-matrix size reconstruction in image quality in arterial CT runoff studies of the lower extremities. Eur Radiol. 2023. PMID: 37382617. doi:10.1007/s00330-023-09841-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。