深度学习图像重建生成的1.25 mm薄层图像能否替代腹部CT标准5 mm图像

Can 1.25 mm thin-section images generated with Deep Learning Image Reconstruction technique replace standard-of-care 5 mm images in abdominal CT?
PubMed 文献 · Abdom Radiol (NY) · 2023-06-27

本回顾性研究纳入52例腹部CT患者,比较1.25 mm深度学习图像重建(DLIR)图像与5 mm自适应统计迭代重建(ASIR-V)图像的质量。DLIR中、高强度组的图像质量评分优于5 mm ASIR-V,DLIR高强度组噪声最低、对比噪声比最高,且不增加辐射剂量。

要点

  • 1.25 mm DLIR薄层图像质量评分优于5 mm ASIR-V图像。
  • DLIR高强度组噪声最低(9.17±3.11)、对比噪声比最高。
  • 各DLIR组伪影评分均优于ASIR-V,组间无显著差异。

核心结论

  • DLIR可生成1.25 mm腹部CT薄层图像,与5 mm ASIR-V图像相比图像质量改善、阅片者间一致性更高。

研究设计与样本

  • 回顾性研究,纳入2019年8月至10月间52例(女性31例,年龄56.9±16.9岁)腹部CT患者。

临床应用与阅片要点

  • 作者指出,DLIR重建薄层CT图像质量改善在临床实践中有多项益处,如在不增加辐射剂量的情况下提高诊断性能。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: CT image reconstruction has evolved from filtered back projection to hybrid- and model-based iterative reconstruction. Deep learning-based image reconstruction is a relatively new technique that uses deep convolutional neural networks to improve image quality.

OBJECTIVE: To evaluate and compare 1.25 mm thin-section abdominal CT images reconstructed with deep learning image reconstruction (DLIR) with 5 mm thick images reconstructed with adaptive statistical iterative reconstruction (ASIR-V).

METHODS: This retrospective study included 52 patients (31 F; 56.9±16.9 years) who underwent abdominal CT scans between August-October 2019. Image reconstruction was performed to generate 5 mm images at 40% ASIR-V and 1.25 mm DLIR images at three strengths (low [DLIR-L], medium [DLIR-M], and high [DLIR-H]). Qualitative assessment was performed to determine image noise, contrast, visibility of small structures, sharpness, and artifact based on a 5-point-scale. Image preference determination was based on a 3-point-scale. Quantitative assessment included measurement of attenuation, image noise, and contrast-to-noise ratios (CNR).

RESULTS: Thin-section images reconstructed with DLIR-M and DLIR-H yielded better image quality scores than 5 mm ASIR-V reconstructed images. Mean qualitative scores of DLIR-H for noise (1.77 ± 0.71), contrast (1.6 ± 0.68), small structure visibility (1.42 ± 0.66), sharpness (1.34 ± 0.55), and image preference (1.11 ± 0.34) were the best (p<0.05). DLIR-M yielded intermediate scores. All DLIR reconstructions showed superior ratings for artifacts compared to ASIR-V (p<0.05), whereas each DLIR group performed comparably (p>0.05, 0.405-0.763). In the quantitative assessment, there were no significant differences in attenuation values between all reconstructions (p>0.05). However, DLIR-H demonstrated the lowest noise (9.17 ± 3.11) and the highest CNR (CNRliver = 26.88 ± 6.54 and CNRportal vein = 7.92 ± 3.85) (all p<0.001).

CONCLUSION: DLIR allows generation of thin-section (1.25 mm) abdominal CT images, which provide improved image quality with higher inter-reader agreement compared to 5 mm thick images reconstructed with ASIR-V.

CLINICAL IMPACT: Improved image quality of thin-section CT images reconstructed with DLIR has several benefits in clinical practice, such as improved diagnostic performance without radiation dose penalties.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。