新发心律失常对经导管主动脉瓣置换术后心脏逆重构的影响:基于计算机断层扫描的左心室与心房应变分析
本研究纳入211例接受TAVR并完成术前及术后6个月心脏CT的患者,52例(24.6%)出现新发心律失常(NOA),24例(11.4%)植入永久起搏器。NOA组植入深度显著大于非NOA组(-6.7±2.4 vs -5.6±2.6 mm,p=0.009);仅非NOA组LV GLS和LA储备应变显著改善(LV GLS -15.5±4.0至-17.3±2.9%,p<0.001;LA储备应变22.3±8.9至26.5±7.6%,p<0.001),且平均百分比变化在非NOA组更明显(p=0.019和p=0.035)。
要点
- TAVR术后约四分之一患者出现新发心律失常,CT显示植入深度更深与NOA相关。
- NOA患者TAVR术后6个月CT-derived左心室整体纵向应变和左心房储备应变未见改善。
- 非NOA患者上述应变指标显著改善,提示心脏逆重构。
核心结论
- TAVR术后新发心律失常与CT所示植入深度更深相关,并损害左心室和左心房的逆重构,表现为应变指标无改善。
研究设计与样本
- 连续纳入接受TAVR并在术前及术后6个月行心脏CT扫描的患者211例(男性41.7%,中位年龄81岁),比较NOA组与非NOA组的植入深度及左心功能与应变。
诊断标准与关键数值
- NOA定义为术后持续超过30天的新发左束支传导阻滞、房室传导阻滞、心房颤动/扑动和/或TAVR后1年内需植入永久起搏器;植入深度NOA组-6.7±2.4 mm vs 非NOA组-5.6±2.6 mm(p=0.009)。
临床应用与阅片要点
- TAVR术后CT可用于评估植入深度,深度更深与NOA风险相关;NOA患者左心应变未见改善,提示管理NOA对优化结局的重要性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Patients who undergo transcatheter aortic valve replacement (TAVR) are at risk for new-onset arrhythmia (NOA) that may require permanent pacemaker (PPM) implantation, resulting in decreased cardiac function. We aimed to investigate the factors that are associated with NOA after TAVR and to compare pre- and post-TAVR cardiac functions between patients with and without NOA using CT-derived strain analyses.
METHODS: We included consecutive patients who underwent pre- and post-TAVR cardiac CT scans six months after TAVR. New-onset left bundle branch block, atrioventricular block, and atrial fibrillation/flutter lasting over 30 days after the procedure and/or the need for PPM diagnosed within 1 year after TAVR were regarded as NOA. Implant depth and left heart function and strains were analyzed using multi-phase CT images and compared between patients with and without NOA.
RESULTS: Of 211 patients (41.7% men; median 81 years), 52 (24.6%) presented with NOA after TAVR, and 24 (11.4%) implanted PPM. Implant depth was significantly deeper in the NOA group than in the non-NOA group (- 6.7 ± 2.4 vs. - 5.6 ± 2.6 mm; p = 0.009). Left ventricular global longitudinal strain (LV GLS) and left atrial (LA) reservoir strain were significantly improved only in the non-NOA group (LV GLS, - 15.5 ± 4.0 to - 17.3 ± 2.9%; p < 0.001; LA reservoir strain, 22.3 ± 8.9 to 26.5 ± 7.6%; p < 0.001). The mean percent change of the LV GLS and LA reservoir strains was evident in the non-NOA group (p = 0.019 and p = 0.035, respectively).
CONCLUSIONS: A quarter of patients presented with NOA after TAVR. Deep implant depth on post-TAVR CT scans was associated with NOA. Patients with NOA after TAVR had impaired LV reserve remodeling assessed by CT-derived strains.
CLINICAL RELEVANCE STATEMENT: New-onset arrhythmia (NOA) following transcatheter aortic valve replacement (TAVR) impairs cardiac reverse remodeling. CT-derived strain analysis reveals that patients with NOA do not show improvement in left heart function and strains, highlighting the importance of managing NOA for optimal outcomes.
KEY POINTS: • New-onset arrhythmia following transcatheter aortic valve replacement (TAVR) is a concern that interferes with cardiac reverse remodeling. • Comparison of pre-and post-TAVR CT-derived left heart strain provides insight into the impaired cardiac reverse remodeling in patients with new-onset arrhythmia following TAVR. • The expected reverse remodeling was not observed in patients with new-onset arrhythmia following TAVR, given that CT-derived left heart function and strains did not improve.
引用
- Park, Kang, Ahn, et al. Impact of new-onset arrhythmia on cardiac reverse remodeling following transcatheter aortic valve replacement: computed tomography-derived left ventricular and atrial strains. Eur Radiol. 2023. PMID: 37368107. doi:10.1007/s00330-023-09836-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。