文献速递胸部技术与安全US

机器学习算法检测融合性B线

Machine Learning Algorithm Detection of Confluent B-Lines.
PubMed 文献 · Ultrasound Med Biol · 2023-06-24

本研究使用157名受试者的416个肺超声 clips,由五名床旁超声专家盲法判定融合性B线的有无,以专家多数一致为参考标准,评估机器学习算法的检测性能。算法检测融合性B线的敏感度和特异度分别为83%和92%,与专家判定的未加权κ为0.75,不同探头间敏感度和特异度无统计学差异。

要点

  • 算法检测融合性B线的敏感度83%、特异度92%,与专家判定一致性好(κ=0.75)。
  • 融合性B线在416个 clips 中占49.5%(206/416),需与单发B线区分。
  • 不同探头(凸阵、扇阵、线阵)间算法敏感度和特异度无统计学差异。

核心结论

  • 融合性B线检测算法在肺超声床旁 clips 中检测融合性B线,与专家判定相比具有高敏感度和特异度。

研究设计与样本

  • 本研究为前瞻性研究的子集分析,纳入两个学术医疗中心因气促就诊的成人,使用手持平板和14区协议采集,最终随机抽取416个 clips(146个凸阵、150个扇阵、120个线阵),由五名床旁超声专家盲法评估融合性B线有无,以专家多数一致为参考标准。

诊断标准与关键数值

  • 算法检测融合性B线的敏感度为83%(95%CI:0.77-0.88),特异度为92%(95%CI:0.88-0.96),参考标准为专家多数一致。
  • 算法与专家判定融合性B线的未加权κ为0.75(95%CI:0.69-0.81)。
  • 不同探头间算法检测融合性B线的敏感度和特异度无统计学差异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: B-lines are a ring-down artifact of lung ultrasound that arise with increased alveolar water in conditions such as pulmonary edema and infectious pneumonitis. Confluent B-line presence may signify a different level of pathology compared with single B-lines. Existing algorithms aimed at B-line counting do not distinguish between single and confluent B-lines. The objective of this study was to test a machine learning algorithm for confluent B-line identification.

METHODS: This study used a subset of 416 clips from 157 subjects, previously acquired in a prospective study enrolling adults with shortness of breath at two academic medical centers, using a hand-held tablet and a 14-zone protocol. After exclusions, random sampling generated a total of 416 clips (146 curvilinear, 150 sector and 120 linear) for review. A group of five experts in point-of-care ultrasound blindly evaluated the clips for presence/absence of confluent B-lines. Ground truth was defined as majority agreement among the experts and used for comparison with the algorithm.

RESULTS: Confluent B-lines were present in 206 of 416 clips (49.5%). Sensitivity and specificity of confluent B-line detection by algorithm compared with expert determination were 83% (95% confidence interval [CI]: 0.77-0.88) and 92% (95% CI: 0.88-0.96). Sensitivity and specificity did not statistically differ between transducers. Agreement between algorithm and expert for confluent B-lines measured by unweighted κ was 0.75 (95% CI: 0.69-0.81) for the overall set.

CONCLUSION: The confluent B-line detection algorithm had high sensitivity and specificity for detection of confluent B-lines in lung ultrasound point-of-care clips, compared with expert determination.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Baloescu, Rucki, Chen, et al. Machine Learning Algorithm Detection of Confluent B-Lines. Ultrasound Med Biol. 2023. PMID: 37365065. doi:10.1016/j.ultrasmedbio.2023.05.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。